Publications by authors named "Andreas Hunkeler"

Progress in NMR in general and in biomolecular applications in particular is driven by increasing magnetic-field strengths leading to improved resolution and sensitivity of the NMR spectra. Recently, persistent superconducting magnets at a magnetic field strength (magnetic induction) of 28.2 T corresponding to 1200 MHz proton resonance frequency became commercially available.

View Article and Find Full Text PDF

The spin dynamics of dissolution DNP samples consisting of 4.5 M [C]urea in a mixture of (1/1) glycerol/water using 4-Oxo-TEMPO as a radical was investigated. We analyzed the DNP dynamics as function of radical concentration at 7 T and 3.

View Article and Find Full Text PDF

Three-dimensional spatially resolved full-volume imaging by magnetic resonance force microscopy at room temperature is described. Spatial resolution in z-dimension is achieved by using the magnetic-field gradient of a ferromagnetic particle that is also used for the force detection of the magnetic resonance. The gradient of the radiofrequency pulses generated by two separate wire-bonded microcoils is used for spatial resolution in x- and y-dimension.

View Article and Find Full Text PDF

Magic-angle spinning (MAS) is mandatory in solid-state NMR experiments to achieve resolved spectra. In rare cases, instabilities in the rotation or damage of either the rotor or the rotor cap can lead to a so called "rotor crash" involving a disintegration of the sample container and possibly the release of an aerosol or of dust. We present a modified design of a 3.

View Article and Find Full Text PDF

We demonstrate the detection of picoliter amounts of water and triethylenetetramine by a magnetic-resonance-force-microscopy (MRFM) setup operated in the gradient-on-cantilever geometry at room temperature. A magnetic field gradient is produced by a ferromagnetic SmCo particle glued to the tip of a micromechanical resonator (cantilever). The liquids are enclosed in a micro-capillary to protect them from the high vacuum environment needed for sensitive detection.

View Article and Find Full Text PDF

Dissolution DNP has become an important method to generate highly polarized substrates such as pyruvic acid for in vivo imaging and localized spectroscopy. In a quest to further increase the polarization levels, which is important for in vivo MRI employing C detection, we describe the design and implementation of a new DNP polarizer that is suitable for dissolution operation at 7 T static magnetic field and a temperature of 1.4 K.

View Article and Find Full Text PDF

The temperature-dependent resonance-line broadening of HET-s(218-289) in its amyloid form is investigated in the range between 110 K and 280 K. Significant differences are observed between residues in the structured hydrophobic triangular core, which are broadened the least and can be detected down to 100 K, and in the solvent-exposed parts, which are broadened the most and often disappear from the observed spectrum around 200 K. Below the freezing of the bulk water, around 273 K, the protein fibrils are still surrounded by a layer of mobile water whose thickness decreases with temperature, leading to drying out of the fibrils.

View Article and Find Full Text PDF

Ice, in addition to "liquid" water and protein, is an important component of protein samples for NMR spectroscopy at subfreezing temperatures but it has rarely been observed spectroscopically in this context. We characterize its spectroscopic behavior in the temperature range from 100 to 273 K, and find that it behaves like pure water ice. The interference of magic-angle spinning (MAS) as well as rf multiple-pulse sequences with Bjerrum-defect motion greatly influences the ice spectra.

View Article and Find Full Text PDF

We discuss the optimum experimental conditions to obtain assignment spectra for solid proteins at magic-angle spinning (MAS) frequencies around 100 kHz. We present a systematic examination of the MAS dependence of the amide proton T 2' times and a site-specific comparison of T 2' at 93 kHz versus 60 kHz MAS frequency. A quantitative analysis of transfer efficiencies of building blocks, as they are used for typical 3D experiments, was performed.

View Article and Find Full Text PDF

Dynamic nuclear polarization (DNP) in combination with subsequent dissolution of the sample allows the detection of low-γ nuclei in the solution state with a signal gain of up to tens of thousand times compared to experiments starting from Boltzmann conditions. The long polarization build-up times of typically more than one hour are a drawback of this technique. The combination of dissolution DNP with cross-polarization (CP) in the solid state was shown to have the potential to overcome this disadvantage.

View Article and Find Full Text PDF

Crystal clear: Preparing solid-state NMR samples that yield high-resolution spectra displaying high sensitivity is time-consuming and complicated. A sample of the 59 kDa protein DnaB, prepared simply by preparative centrifugation, provides spectra that are as good as the ones from carefully grown microcrystals.

View Article and Find Full Text PDF

We describe the design and initial performance results of a multi-sample dissolution dynamic-nuclear-polarization (DNP) polarizer based on a Helium-temperature NMR cryostat for use in a wide-bore NMR magnet with a room-temperature bore. The system is designed to accommodate up to six samples in a revolver-style sample changer that allows changing samples at liquid-Helium temperature and at pressures ranging from ambient pressure down to 1 mbar. The multi-sample setup is motivated by the desire to do repetitive in vivo measurements and to characterize the DNP process by investigating samples of different chemical composition.

View Article and Find Full Text PDF

We observed and characterized two distinct signals originating from different pools of water protons in solid-state NMR protein samples, namely from crystal water which exchanges polarization with the protein (on the NMR timescale) and is located in the protein-rich fraction at the periphery of the magic-angle spinning (MAS) sample container, and supernatant water located close to the axis of the sample container. The polarization transfer between the water and the protein can be probed by two-dimensional exchange spectroscopy, and we show that the supernatant water does not interact with protein on the timescale of the experiments. The two water pools have different spectroscopic properties, including resonance frequency, longitudinal, transverse and rotating frame relaxation times.

View Article and Find Full Text PDF

Magnetic-resonance force microscopy is combined with cross-polarization and spin-decoupling NMR techniques to obtain double-resonance NMR signals of micrometer-scaled objects. The effective one-dimensional spatial resolution obtained in our experiments performed on a KPF6 single crystal sample is approximately 0.5 microm.

View Article and Find Full Text PDF

In a model study, the proton NMR spectrum of the opioid pentapeptide leucine-enkephalin associated with bicelles is investigated. The spectral resolution for a static sample is limited due to the large number of anisotropic interactions, in particular strong proton-proton couplings, but resolution is greatly improved by magic-angle sample spinning. Here we present two-dimensional switched-angle spinning NMR experiments, which correlate the high-resolution spectrum of the membrane-bound peptide under magic-angle spinning with its anisotropic spectrum, leading to well-resolved spectra.

View Article and Find Full Text PDF