Injuries to the hamstring muscles are an increasing problem in sports. Imaging plays a key role in diagnosing and managing athletes with muscle injuries, but there are several problems with conventional imaging modalities with respect to cost and availability. We hypothesized that microwave imaging could provide improved availability and lower costs and lead to improved and more accurate diagnostics.
View Article and Find Full Text PDFAbdominal injury is a frequent cause of death for trauma patients, and early recognition is essential to limit fatalities. There is a need for a wearable sensor system for prehospital settings that can detect and monitor bleeding in the abdomen (hemoperitoneum). This study evaluates the potential for microwave technology to fill that gap.
View Article and Find Full Text PDFIEEE Trans Microw Theory Tech
May 2021
This paper describes a fast microwave tomography reconstruction algorithm based on the two-dimensional discrete dipole approximation. Synthetic data from a finite-element based solver and experimental data from a microwave imaging system are used to reconstruct images and to validate the algorithm. The microwave measurement system consists of 16 monopole antennas immersed in a tank filled with lossy coupling liquid and a vector network analyzer.
View Article and Find Full Text PDFThis paper focuses on the construction of the Jacobian matrix required in tomographic reconstruction algorithms. In microwave tomography, computing the forward solutions during the iterative reconstruction process impacts the accuracy and computational efficiency. Towards this end, we have applied the discrete dipole approximation for the forward solutions with significant time savings.
View Article and Find Full Text PDFQuick on-scene assessment and early intervention is the key to reduce the mortality of stroke and trauma patients, and it is highly desirable to develop ambulance-based diagnostic and monitoring devices in order to provide additional support to the medical personnel. We developed a compact and low cost ultra wideband noise sensor for medical diagnostics and vital sign monitoring in pre-hospital settings. In this work, we demonstrated the functionality of the sensor for respiration and heartbeat monitoring.
View Article and Find Full Text PDFEarly, preferably prehospital, detection of intracranial bleeding after trauma or stroke would dramatically improve the acute care of these large patient groups. In this paper, we use simulated microwave transmission data to investigate the performance of a machine learning classification algorithm based on subspace distances for the detection of intracranial bleeding. A computational model, consisting of realistic human head models of patients with bleeding, as well as healthy subjects, was inserted in an antenna array model.
View Article and Find Full Text PDFIEEE J Electromagn RF Microw Med Biol
June 2019
The two-dimensional electric field distribution of the microwave imaging system is numerically simulated for a simplified breast tumour model. The proposed two-dimensional discrete dipole approximation (DDA) has the potential to improve computational speed compared to other numerical methods while retaining comparable accuracy. We have modeled the field distributions in COMSOL Multiphysics as baseline results to benchmark the DDA simulations.
View Article and Find Full Text PDFWe introduce the discrete dipole approximation (DDA) for efficiently calculating the two-dimensional electric field distribution for our microwave tomographic breast imaging system. For iterative inverse problems such as microwave tomography, the forward field computation is the time limiting step. In this paper, the two-dimensional algorithm is derived and formulated such that the iterative conjugate orthogonal conjugate gradient (COCG) method can be used for efficiently solving the forward problem.
View Article and Find Full Text PDFDiagnostics (Basel)
September 2018
A breast phantom developed at the Supelec Institute was interrogated to study its suitability for microwave tomography measurements. A microwave measurement system based on 16 monopole antennas and a vector network analyzer was used to study how the S-parameters are influenced by insertion of the phantom. The phantom is a 3D-printed structure consisting of plastic shells that can be filled with tissue mimicking liquids.
View Article and Find Full Text PDFTraumatic brain injury is the leading cause of death and severe disability for young people and a major public health problem for elderly. Many patients with intracranial bleeding are treated too late, because they initially show no symptoms of severe injury and are not transported to a trauma center. There is a need for a method to detect intracranial bleedings in the prehospital setting.
View Article and Find Full Text PDFHere, we present two different brain diagnostic devices based on microwave technology and the associated two first proof-of-principle measurements that show that the systems can differentiate hemorrhagic from ischemic stroke in acute stroke patients, as well as differentiate hemorrhagic patients from healthy volunteers. The system was based on microwave scattering measurements with an antenna system worn on the head. Measurement data were analyzed with a machine-learning algorithm that is based on training using data from patients with a known condition.
View Article and Find Full Text PDFNonlinear microwave imaging heavily relies on an accurate numerical electromagnetic model of the antenna system. The model is used to simulate scattering data that is compared to its measured counterpart in order to reconstruct the image. In this paper an antenna system immersed in water is used to image different canonical objects in order to investigate the implication of modeling errors on the final reconstruction using a time domain-based iterative inverse reconstruction algorithm and three-dimensional FDTD modeling.
View Article and Find Full Text PDFMicrowave imaging for breast cancer detection has been of significant interest for the last two decades. Recent studies focus on solving the imaging problem using an inverse scattering approach. Efforts have mainly been focused on the development of the inverse scattering algorithms, experimental setup, antenna design and clinical trials.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
January 2012
In this paper, quantitative dielectric image reconstruction based on broadband microwave measurements is investigated. A time-domain-based algorithm is derived where Debye model parameters are reconstructed in order to take into account the strong dispersive behavior found in biological tissue. The algorithm is tested with experimental and numerical data in order to verify the algorithm and to investigate improvements in the reconstructed image resulting from the improved description of the dielectric properties of the tissue when using broadband data.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
August 2006
A tomographic time-domain reconstruction algorithm for solving the inverse electromagnetic problem is described. The application we have in mind is dielectric breast cancer detection but the results are of general interest to the field of microwave tomography. Reconstructions have been made from experimental and numerically simulated data for objects of different sizes in order to investigate the relation between the spectral content of the illuminating pulse and the quality of the reconstructed image.
View Article and Find Full Text PDFElectromagn Biol Med
May 2006
Microwave imaging is an interesting and growing research field with a number of medical applications. This paper is based on the first series of experimental results using an iterative gradient algorithm based on the finite difference time domain (FDTD) method and synthetic pulses. Using our method, the permittivity and conductivity of an object are reconstructed layer by layer by minimizing a functional consisting of the difference between the measured and calculated electric field surrounding the object.
View Article and Find Full Text PDF