Publications by authors named "Andreas Ehn"

Methyl is crucial in plasma-assisted hydrocarbon chemistry, making precise in situ imaging essential for understanding various plasma applications. Its importance in methane chemistry arises from its role as a primary byproduct during the initial phase of methane dehydrogenation. Detecting the CH radical is challenging due to its high reactivity and the prevalence of strongly pre-dissociative electronically excited states.

View Article and Find Full Text PDF

The reduction of greenhouse gas emissions and the effort of carbon neutrality require the improvement of spark-ignition engines in terms of efficiency and capability to operate on renewable fuels. The electrode wear of spark plugs, used for ignition of novel fuels and lean mixtures, emerges as a significant challenge in this transition. Understanding the physical mechanism and influence of spark operation parameters of the wear process is thus important.

View Article and Find Full Text PDF

The plasma-surface interface has sparked interest due to its potential of creating alternative reaction pathways not available in typical gas-surface reactions. Currently, there are a limited number of in situ studies investigating the plasma-surface interface, restricting the development of its application. Here, we report the use of in situ ambient pressure X-ray photoelectron spectroscopy in tandem with an optical spectrometer to characterize the hydrogen plasma's interaction with metal surfaces.

View Article and Find Full Text PDF

Fluorescence lifetime determination has proven to be useful, e.g. identification of molecules, quantitative estimation of species concentration and determination of temperatures.

View Article and Find Full Text PDF

Periodic shadowing, a concept used in spectroscopy for stray light reduction, has been implemented to improve the temporal contrast of streak camera imaging. The capabilities of this technique are first proven by imaging elastically scattered picosecond laser pulses and are further applied to fluorescence lifetime imaging, where more accurate descriptions of fluorescence decay curves were observed. This all-optical approach can be adapted to various streak camera imaging systems, resulting in a robust technique to minimize space-charge induced temporal dispersion in streak cameras while maintaining temporal coverage and spatial information.

View Article and Find Full Text PDF

Fluorescence-based multispectral imaging of rapidly moving or dynamic samples requires both fast two-dimensional data acquisition as well as sufficient spectral sensitivity for species separation. As the number of fluorophores in the experiment increases, meeting both these requirements becomes technically challenging. Although several solutions for fast imaging of multiple fluorophores exist, they all have one main restriction; they rely solely on spectrally resolving either the excitation- or the emission characteristics of the fluorophores.

View Article and Find Full Text PDF

Stray light is a known strong interference in spectroscopic measurements. Photons from high-intensity signals that are scattered inside the spectrometer, or photons that enter the detector through unintended ways, will be added to the spectrum as an interference signal. A general experimental solution to this problem is presented here by introducing a customized fiber for signal collection.

View Article and Find Full Text PDF

Many important scientific questions in physics, chemistry and biology rely on high-speed optical imaging techniques for their investigations. These techniques are either passive, relying on the rapid readout of photoactive elements, or active, relying on the illumination properties of specially designed pulse trains. Currently, MHz imaging speeds are difficult to realize; passive methods, being dictated by electronics, cause the unification of high spatial resolution with high frame rates to be very challenging, while active methods rely on expensive and complex hardware such as femto- and picosecond laser sources.

View Article and Find Full Text PDF

In this Letter, we have investigated 845 nm lasing generation in atomic oxygen, present in a lean methane-air flame, using two-photon pumping with femtosecond 226 nm laser pulses, particularly focusing on the impact of nanosecond repetitively pulsed glow discharges forcing on the backward lasing signal. Characterizations of the backward lasing pulse, in terms of its spectrum, beam profile, pump pulse energy dependence, and divergence, were conducted to establish the presence of lasing. With plasma forcing of the flame, the backward lasing signal was observed to be enhanced significantly, ∼50%.

View Article and Find Full Text PDF

Many important scientific questions in physics, chemistry and biology require effective methodologies to spectroscopically probe ultrafast intra- and inter-atomic/molecular dynamics. However, current methods that extend into the femtosecond regime are capable of only point measurements or single-snapshot visualizations and thus lack the capability to perform ultrafast spectroscopic videography of dynamic single events. Here we present a laser-probe-based method that enables two-dimensional videography at ultrafast timescales (femtosecond and shorter) of single, non-repetitive events.

View Article and Find Full Text PDF

Translational, rotational, vibrational and electron temperatures of a gliding arc discharge in atmospheric pressure air were experimentally investigated using in situ, non-intrusive optical diagnostic techniques. The gliding arc discharge was driven by a 35 kHz alternating current (AC) power source and operated in a glow-type regime. The two-dimensional distribution of the translational temperature (Tt) of the gliding arc discharge was determined using planar laser-induced Rayleigh scattering.

View Article and Find Full Text PDF

In the present work, the spectral properties of gaseous ozone (O) have been investigated aiming to perform quantitative concentration imaging of ozone by using a single laser pulse at 248 nm from a KrF excimer laser. The O molecule is first photodissociated by the laser pulse into two fragments, O and O. Then the same laser pulse electronically excites the O fragment, which is vibrationally hot, whereupon fluorescence is emitted.

View Article and Find Full Text PDF

Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities.

View Article and Find Full Text PDF

We present an optical solution called DMD-PS to boost the dynamic range of 2D imaging spectroscopic measurements up to 22 bits by incorporating a digital micromirror device (DMD) prior to detection in combination with the periodic shadowing (PS) approach. In contrast to high dynamic range (HDR), where the dynamic range is increased by recording several images at different exposure times, the current approach has the potential of improving the dynamic range from a single exposure and without saturation of the CCD sensor. In the procedure, the spectrum is imaged onto the DMD that selectively reduces the reflection from the intense spectral lines, allowing the signal from the weaker lines to be increased by a factor of 2 via longer exposure times, higher camera gains or increased laser power.

View Article and Find Full Text PDF

A laser method to suppress background interferences in pump-probe measurements is presented and demonstrated. The method is based on structured illumination, where the intensity profile of the pump beam is spatially modulated to make its induced photofragment signal distinguishable from that created solely by the probe beam. A spatial lock-in algorithm is then applied on the acquired data, extracting only those image components that are characterized by the encoded structure.

View Article and Find Full Text PDF

A laser diagnostic concept for measurement of potassium chloride (KCl) and potentially other alkali compounds in large-scale boilers and furnaces of limited optical access is presented. Single-ended, range-resolved, quantitative detection of KCl is achieved by differential absorption light detection and ranging (DIAL) based on picosecond laser pulses. Picosecond DIAL results have been compared experimentally with line-of-sight measurements using a commercial instrument, the in situ alkali chloride monitor (IACM), utilizing differential optical absorption spectroscopy.

View Article and Find Full Text PDF

It is well known that spectroscopic measurements suffer from an interference known as stray light, causing spectral distortion that reduces measurement accuracy. In severe situations, stray light may even obscure the existence of spectral lines. Here a novel general method is presented, named Periodic Shadowing, that enables effective stray light elimination in spectroscopy and experimental results are provided to demonstrate its capabilities and versatility.

View Article and Find Full Text PDF

A novel technique, designated dual imaging and modeling evaluation (DIME), for evaluating single-laser shot fluorescence lifetimes is presented. The technique is experimentally verified in a generic gas mixing experiment to provide a clear demonstration of the rapidness and sensitivity of the detector scheme. Single-laser shot fluorescence lifetimes of roughly 800 ps with a standard deviation of ~120 ps were determined.

View Article and Find Full Text PDF

A temporal filtering technique, complementary to spectral filtering, has been developed for laser-induced fluorescence measurements. The filter is applicable in cases where the laser-induced interfering signals and the signal of interest have different temporal characteristics. For the interfering-signal discrimination a picosecond laser system along with a fast time-gated intensified CCD camera were used.

View Article and Find Full Text PDF

In the present work, a picosecond lidar system aiming at single-ended combustion diagnostics in full-scale combustion devices with limited optical access, such as power plants, is described. The highest overall range resolution of the system was found to be <0.5 cm.

View Article and Find Full Text PDF