Publications by authors named "Andreas Eggspuehler"

Purpose: We compared the value of different uni- and multimodal intraoperative neurophysiological monitoring (IONM) methods on the detection of neurological complications during spine surgery.

Methods: IONM data derived from sensory spinal and cortical evoked potentials combined with continuous electromyography monitoring, motor evoked potentials and spinal recording were evaluated in relation to subsequent post-operative neurological changes. Patients were categorised based on their true-positive or true-negative post-operative neurological status.

View Article and Find Full Text PDF

Pterygium is a vascularized, invasive transformation on the anterior corneal surface that can be treated by Strontium-/Yttrium90 beta irradiation. Finite element modeling was used to analyze the biomechanical effects governing the treatment, and to help understand clinically observed changes in corneal astigmatism. Results suggested that irradiation-induced pulling forces on the anterior corneal surface can cause astigmatism, as well as central corneal flattening.

View Article and Find Full Text PDF

Background: Back pain is common in industrialized countries and one of the most frequent causes of work incapacity. Successful treatment is, therefore, not only important for improving the symptoms and the quality of life of these patients but also for socioeconomic reasons. Back pain is frequently caused by degenerative spine disease.

View Article and Find Full Text PDF

A prospective study on 409 patients who received multimodel intraoperative monitoring (MIOM) during lumbosacral surgical procedures between March 2000 and December 2005 was carried out. The objective of this study was to determine the sensitivity and specificity of MIOM techniques used to monitor conus medullaris, cauda equina and nerve root function during lumbosacral decompression surgery. MIOM has increasingly become important to monitor ascending and descending pathways, giving immediate feedback information regarding any neurological deficit during the decompression and stabilisation procedure in the lumbosacral region.

View Article and Find Full Text PDF

A prospective study of 1,017 patients who received MIOM during spine surgery procedures between March 2000 and December 2005. To determine the sensitivity and specificity of MIOM techniques used to monitor spinal cord and nerve roots function during spine surgery. MIOM has become a widely used method of monitoring neural function during spine surgery.

View Article and Find Full Text PDF

In a prospective study of 109 patients with tumor of the spine MIOM was performed during the surgical procedure between March 2000 and December 2005. To determine the sensitivity and specificity of MIOM techniques used to monitor spinal cord and nerve root function during surgical procedure of spinal tumors. MIOM become an integrated procedure during surgical approach to intramedullar and extramedullar spine tumors.

View Article and Find Full Text PDF

To describe different currently available tests of multimodal intraoperative monitoring (MIOM) used in spine and spinal cord surgery indicating the technical parameters, application and interpretation as an easy understanding systematic overview to help implementation of MIOM and improve communication between neurophysiologists and spine surgeons. This article aims to give an overview and proposal of the different MIOM-techniques as used daily in spine and spinal cord surgery at our institution. Intensive research in neurophysiology over the past decades has lead to a profound understanding of the spinal cord, nerve functions and their intraoperative functional evaluation in anaesthetised patients.

View Article and Find Full Text PDF

A prospective study was performed on 217 patients who received MIOM during corrective surgery of spinal deformities between March 2000 and December 2005. Aim is to determine the sensitivity and specificity of MIOM techniques used to monitor spinal cord and nerve root function during corrective spine surgery. MIOM is becoming an increasingly used method of monitoring function during corrective spine surgery.

View Article and Find Full Text PDF

A prospective study of 246 patients who received multimodal intraoperative monitoring during cervical spine surgery between March 2000 and December 2005. To determine the sensitivity and specificity of MIOM techniques used to monitor spinal cord and nerve root function during cervical spine surgery. It is appreciated that complication rate of cervical spine surgery is low, however, there is a significant risk of neurological injury.

View Article and Find Full Text PDF

A prospective study of 36 patients who received multimodal intraoperative monitoring (MIOM) during decompression of thoracic spinal stenosis between March 2000 and December 2005 was chosen as the study design. The objective was to determine the sensitivity and specificity of MIOM techniques used for monitoring spinal cord during surgical thoracic decompression. The background data revealed that the surgical decompression for thoracic spinal stenosis is less frequent than in other regions of the spine.

View Article and Find Full Text PDF