Metabolite profiling using gas chromatography coupled to mass spectrometry (GC-MS) is one of the most frequently applied and standardized methods in research projects using metabolomics to analyze complex samples. However, more than 20 years after the introduction of non-targeted approaches using GC-MS, there are still unsolved challenges to accurate quantification in such investigations. One particularly difficult aspect in this respect is the occurrence of sample-dependent matrix effects.
View Article and Find Full Text PDFOn-site analysis of volatile organic compounds (VOCs) with miniaturized gas chromatography-mass spectrometry (GC-MS) systems is a very rapidly developing field of application. While, on the one hand, major technological advances are improving the availability of these systems on the market, on the other hand, systematic studies to assess the performance of such instruments are still lacking. To fill this gap, we compared three portable GC-MS devices to a state-of-the-art benchtop (stationary) system for analysis of a standard mixture of 18 VOCs.
View Article and Find Full Text PDFPrevious studies showed that olfactory cues are important for mammalian communication. However, many specific compounds that convey information between conspecifics are still unknown. To understand mechanisms and functions of olfactory cues, olfactory signals such as volatile compounds emitted from individuals need to be assessed.
View Article and Find Full Text PDFVolatile organic compounds (VOCs) are commonly collected from gaseous samples by adsorption to materials such as the porous polymer Tenax TA. Adsorbed compounds are subsequently released from these materials by thermal desorption (TD) and separated then by gas chromatography (GC) with flame ionization (FID) or mass spectrometry (MS) detection. Tenax TA is known to be particularly suitable for non-polar to semipolar volatiles, however, many volatiles from environmental and biological samples possess a rather polar character.
View Article and Find Full Text PDFAccurate quantitation of compounds in samples of biological origin is often hampered by matrix interferences one of which occurs in GC-MS analysis from the presence of highly abundant phosphate. Consequently, high concentrations of phosphate need to be removed before sample analysis. Within this context, we screened 17 anion exchange solid-phase extraction (SPE) materials for selective phosphate removal using different protocols to meet the challenge of simultaneous recovery of six common organic acids in aqueous samples prior to derivatization for GC-MS analysis.
View Article and Find Full Text PDF