Publications by authors named "Andrea Bonardi"

The aim of this study is to report the results and to review the outcome of 14 cases of Y-T humeral fractures repair using paired polyaxial locking system (PAX) plates through a combined medial and lateral approach. Fourteen consecutive dogs, with traumatic humeral Y-T fractures, met the inclusion criteria. This study includes signalment, preoperative radiographs, type of implants, radiographic bone healing assessment, complications, range of motion (ROM) of the elbow and limb function evaluated at 120 days after surgery.

View Article and Find Full Text PDF

The objective of this study is to evaluate the difference between the amount of bone visible with the superimposition of a radiolucent hybrid external fixator and a graphically simulated metallic frame. Eighteen frames were applied to eighteen bone specimens. The fracture area (FA), the radiolucent area (RLA) and the radiopaque area (ROA) inside the FA were calculated for each construct on both postoperative views.

View Article and Find Full Text PDF

Objectives: The aim of the study was to describe the differences in pelvic limb alignment between healthy purebred English Bulldogs and those with medial patellar luxation through the measurement of femoral and tibial angles on computed tomography images in multiplanar reconstruction modality (MPR-CT).

Methods: Twenty-one purebred English Bulldogs were included and divided into two groups: one including healthy dogs (15 limbs) and the other including those with medial patellar luxation (24 limbs). Three different observers used MPR-CT to measure the following angles: anatomical lateral proximal femoral angle (aLPFA), anatomical lateral distal femoral angle (aLDFA), mechanical lateral proximal femoral angle (mLPFA), mechanical lateral distal femoral angle (mLDFA), angle of inclination of the femoral neck (AI), angle of anteversion (AA), mechanical medial proximal tibial angle (mMPTA), mechanical medial distal tibial angle (mMDTA), mechanical caudal distal tibial angle (mCdDTA), mechanical caudal proximal tibial angle (mCdPTA), and the tibial torsion angle (TTA).

View Article and Find Full Text PDF

Objective: Evaluation of the bending properties in one direction of three titanium polyaxial locking plate systems.

Materials And Methods: The Polyaxial Advanced Locking System (PAX) straight plate (PAX SP), the PAX reconstruction plate (PAX RP), and the VetLOX reconstruction plates (VetLOX) were evaluated individually and as constructs applied to a bone model simulating a fracture gap and compared using a two-way analysis of variance and Tukey post-hoc analysis.

Results: The PAX SP had the highest values of bending stiffness, bending structural stiffness and bending strength.

View Article and Find Full Text PDF