Food matrices consist of many components with different physical and chemical properties that may influence instrumental robustness. The soybean contains fatty coextractives which may have a deleterious effect on the gas chromatography (GC) system. In this study, the efficiencies of PSA, COH, C, silica, aluminum oxide, and Florisil, as dSPE clean-up sorbents, were evaluated by the high-performance liquid chromatography (HPLC) diode-array detector and evaporative light-scattering detector analysis.
View Article and Find Full Text PDFHydrophilic interaction liquid chromatography is an alternative liquid chromatography mode for separation of polar compounds. In the recent years, this liquid chromatography mode has been recognized as an important solution for the analysis of compounds not amenable to reverse phase chromatography. In this work, we evaluated three different hydrophilic liquid chromatography stationary phases for the determination of 14 highly polar anionic molecules including pesticides such as glyphosate, glufosinate, ethephon and fosetyl, their main metabolites, and bromide, chlorate, and perchlorate.
View Article and Find Full Text PDFIn this work, an easy and fast procedure for the selective multiresidue determination of 14 highly polar pesticides (including glyphosate, glufosinate, ethephon and fosetyl) and metabolites in beverages is presented. After an initial sample dilution (1:1, v/v), the extract is shaken and centrifuged, further diluted and then injected directly into the LC-MS/MS system, using hydrophilic interaction liquid chromatography (HILIC) and tandem mass spectrometry. No clean-up procedure was needed.
View Article and Find Full Text PDFThe effectiveness of highly polar pesticides in agriculture is well known, while their low costs contribute to the frequent use. On the other hand, their physicochemical properties make their analytical determination a challenging task. The aim of this study is the evaluation of a methanol-based extraction method with a simple clean-up step using a selective multiresidue LC-MS/MS method for 14 highly polar pesticides and their metabolites.
View Article and Find Full Text PDFThis paper describes the optimization and validation of an acetonitrile based method for simultaneous extraction of multiple pesticides and mycotoxins from raw coffee beans followed by LC-ESI-MS/MS determination. Before extraction, the raw coffee samples were milled and then slurried with water. The slurried samples were spiked with two separate standard solutions, one containing 131 pesticides and a second with 35 mycotoxins, which were divided into 3 groups of different relative concentration levels.
View Article and Find Full Text PDFThis study describes the optimization and single-laboratory validation of a single residue method for determination of two bipyridylium herbicides, paraquat and diquat, in cowpeas by UPLC-MS/MS in a total run time of 9.3min. The method is based on extraction with an acidified methanol-water mixture.
View Article and Find Full Text PDFThis paper presents the validation and further miniaturisation of the well-known Dutch mini-Luke method for high water and acid content matrices for 175 pesticides amenable to liquid- and gas chromatography-mass spectrometry. For optimisation of the method, recovery tests with different sample/extraction solvent ratios, varying amounts of dichloromethane and salts were performed with fifty representative pesticides. Solvent consumption could be reduced considerably, especially for the dichloromethane (by a factor of 3).
View Article and Find Full Text PDFLiquid chromatography-tandem mass spectrometry (LC-MS/MS) is one of the most widely used techniques for identification (and quantification) of residues and contaminants across a number of different chemical domains. Although the same analytical technique is used, the parameters and criteria for identification vary depending on where in the world the analysis is performed and for what purpose (e.g.
View Article and Find Full Text PDFA fast and efficient multimethod for the determination of 36 mycotoxins in wine, using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), was developed, optimized, validated and implemented in routine analysis. A simplified, quick extraction was performed with acetonitrile, derived from the QuEChERS (quick, easy, cheap, effective, rugged and safe) approach, which was traditionally developed for pesticides analysis. This study aimed at a single extraction and chromatographic separation for 36 mycotoxins.
View Article and Find Full Text PDFIn this study, a new gas chromatography-mass spectrometry (GC-MS) method, using the very selective negative chemical ionization (NCI) mode, was developed and applied in combination with a modified acetonitrile-based extraction method (QuEChERS) for the analysis of a large number of pesticide residues (51 pesticides, including isomers and degradation products) in green coffee beans. A previously developed integrated sample homogenization and extraction method for both pesticides and mycotoxins analysis was used. An homogeneous slurry of green milled coffee beans and water (ratio 1:4, w/w) was prepared and extracted with acetonitrile/acetic acid (1%), followed by magnesium sulfate addition for phase separation.
View Article and Find Full Text PDFAn acetonitrile-based extraction method for the analysis of 169 pesticides in soya grain, using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive and negative electrospray ionization (ESI) mode, has been optimized and validated. This method has been compared with our earlier published acetone-based extraction method, as part of a comprehensive study of both extraction methods, in combination with various gas chromatography-(tandem) mass spectrometry [GC-MS(/MS)] and LC-MS/MS techniques, using different detection modes. Linearity of calibration curves, instrument limits of detection (LODs) and matrix effects were evaluated by preparing standards in solvent and in the two soya matrix extracts from acetone and acetonitrile extractions, at seven levels, with six replicate injections per level.
View Article and Find Full Text PDFIn this study, a new modulator that is simple, robust and presents low operation costs, was developed. This modulator uses compressed air to cool two small portions in the first centimeters of the second chromatographic column of a comprehensive multidimensional gas chromatography (GCxGC) system. The results show a variation in the peak area less than 3 and 5% to alkanes and pesticides, respectively.
View Article and Find Full Text PDFA liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) multi-residue method for the simultaneous target analysis of a wide range of pesticides and metabolites in fruit, vegetables and cereals has been developed. Gradient elution has been used in conjunction with positive mode electrospray ionization tandem mass spectrometry to detect up to 171 pesticides and/or metabolites in different crop matrices using a single chromatographic run. Pesticide residues were extracted/partitioned from the samples with acetone/dichloromethane/light petroleum.
View Article and Find Full Text PDFPart of a comprehensive study on the comparison of different extraction methods, GC-MS(/MS) and LC-MS/MS detection methods and modes, for the analysis of soya samples is described in this paper. The validation of an acetone-based extraction method for analysis of 169 pesticides in soya, using LC-MS/MS positive and negative electrospray ionisation (ESI) mode, is reported. Samples (5 g) were soaked with 10 g water and subsequently extracted with 100 mL of a mixture of acetone, dichloromethane and light petroleum (1:1:1), in the presence of 15 g anhydrous sodium sulphate.
View Article and Find Full Text PDFValidation experiments were conducted of a simple, fast, and inexpensive method for the determination of 229 pesticides fortified at 10-100 ng/g in lettuce and orange matrixes. The method is known as the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for pesticide residues in foods. The procedure involved the extraction of a 15 g sample with 15 mL acetonitrile, followed by a liquid-liquid partitioning step performed by adding 6 g anhydrous MgSO4 plus 1.
View Article and Find Full Text PDFA quantitative and confirmatory method for the analysis of trinexapac (free acid metabolite of trinexapac-ethyl) in wheat is described. Residues were extracted from wheat with acetonitrile in aqueous phosphate buffer (pH 7) overnight. The extract was directly injected into the HPLC system.
View Article and Find Full Text PDFA method for the determination of propamocarb in vegetables with liquid chromatography-electrospray ionisation mass spectrometry (LC-ESI-MS) was developed. The performance of a polymer-based analytical LC column for the separation was investigated. Residues of propamocarb were extracted from the matrix with methanol.
View Article and Find Full Text PDF