Publications by authors named "Andre Luis Faria-e-Silva"

Article Synopsis
  • * Maxillary central incisors were used, with color changes measured before and after treatment, plus after a year of storage, revealing that color became more yellow over time.
  • * Results indicated that neither the sealing method nor the access approach influenced tooth discoloration significantly, though more voids were noted with the Bio-C sealer when using minimally invasive access.
View Article and Find Full Text PDF

This study aimed to evaluate the effects of different scaling protocols on the morphology and roughness of the root dentin substrate exposure to ionizing radiation. One hundred and thirty extracted bovine incisors were randomly divided into two groups (n=65): non-irradiated (NIR) and irradiated (IR). Each group was initially subdivided into three subgroups according to the type of non-surgical periodontal protocol: NIT: no instrumentation; HS: hand scaling with 15 apical-coronal instrument movements; US: ultrasonic scaling with 15 apical-coronal cycles.

View Article and Find Full Text PDF

This study evaluated the effects of surrounding and background shades on the color adjustment potential (CAP) and visual color match of two single-shade composites, Vittra APS Unique and Charisma Diamond One. Cylinder-shaped specimens were constructed, consisting of either single-shade composites alone (simple) or composites surrounded by the Forma material at shades A1 or A3 (dual). Simple specimens using only the Forma at the specified shades were also prepared.

View Article and Find Full Text PDF

This study assessed the reliability of a color measurement method using images obtained from a charge-coupled device (CCD) camera and a stereoscopic loupe. Disc-shaped specimens were created using the composite Filtek Z350 XT (shades DA1, DA2, DA3, and DA4) (n = 3). CIELAB color coordinates of the specimens were measured using the spectrophotometer SP60 over white and black backgrounds.

View Article and Find Full Text PDF

Background: Repositioning guides are commonly employed in clinical studies to ensure consistent tooth color measurements. Yet, their influence on measured color remains uncertain.

Objective: This study evaluated the impact of repositioning guides' color and usage on tooth color measurement using a clinical spectrophotometer.

View Article and Find Full Text PDF

This study assessed the color-matching ability and color recovery of unprepared teeth when using single-shade composites and a universal composite in large restorations. Buccal and palatine surface colors of molars were measured with a spectrophotometer (CIELAB) before preparing round cavities (6 mm in diameter, 2 mm in depth). The cavities were randomly filled with a single-shade composite (Omnichroma, Diamond One, or Vittra APS Unique) or a universal composite (Filtek Universal).

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the impact of substrate color and interface distance on the color adjustment of 2 single-shade composites, Vittra APS Unique and Charisma Diamond One.

Materials And Methods: Dual disc-shaped specimens were created using Vittra APS Unique or Charisma Diamond One as the center composite, surrounded by shaded composites (A1 or A3). Color measurements were taken with a spectrophotometer against a gray background, recording the color coordinates in the CIELAB color space.

View Article and Find Full Text PDF

Background: Light-cured resins are widely used as gingival barriers to protect the gums from highly concentrated peroxides used in tooth bleaching. The impact of barrier brand on clinical outcomes is typically considered negligible. However, there is limited evidence on the effects of different brands on operator experience, barrier adaptation, and patient comfort.

View Article and Find Full Text PDF

Statement Of Problem: Visual shade selection in dentistry may be influenced by factors that include the background color and the illuminant.

Purpose: The purpose of this clinical study was to evaluate the influence of using a gray background and a light-correcting device on visual shade selection.

Material And Methods: Two experienced clinicians assessed the incisor color of 30 volunteers using the VITA 3D-MASTER shade guide.

View Article and Find Full Text PDF

Objective: To evaluate the clinical relevance of using the XP-endo Finisher as a supplementary tool to improve the success of root canal treatment of posterior teeth with apical periodontitis, as assessed by 1-year follow-up.

Methods: A randomized clinical trial was conducted with 92 posterior teeth with apical periodontitis. Root canal treatment was performed using a single reciprocating file, with or without the supplementary use of the XP-endo Finisher.

View Article and Find Full Text PDF

This clinical trial investigated the effects of pre-application enamel moistening on the impact of a 37% carbamide peroxide whitener on tooth color changes and the influence of repositioning guide colors. Forty participants were randomly assigned to in-office tooth bleaching with either moistened enamel (experimental) or dry enamel (control). The whitener was applied for 45 min over two sessions.

View Article and Find Full Text PDF

This study analyzed the prevalence of lectures involving esthetics in the scientific program of Brazilian dental conferences and the gender distribution of speakers. All lectures presented in three dental conferences (Bahia, São Paulo, and Goiás states) held from 2016 to 2020 were evaluated. Three investigators individually divided the lectures according to the specialties recognized by the Brazilian Federal Council of Dentistry (FCD) based on their titles.

View Article and Find Full Text PDF

Objective: This study assessed how the distance from the composite interface and the underlying chromatic substrate affect the color adjustment potential (CAP) of two single-shade composites.

Materials And Methods: Cylinder-shaped specimens were created using Vittra APS Unique (VU), Charisma Diamond One (DO), and a shaded (A3) composite. Some single-shade specimens were surrounded by the A3 composite, forming dual specimens.

View Article and Find Full Text PDF

This study evaluated the background and effect of surrounding colors on the color blending of a single-shade composite used in a thin layer. Disc-shaped specimens (1.0 mm thickness) were built with the Vittra APS Unique composite surrounded (dual specimens) or not surrounded (simple specimens) by a control composite (shade A1, A2, or A3).

View Article and Find Full Text PDF

Objectives: The present systematic review and network meta-analysis of randomized control trials (RCTs) aimed to establish whether there are evidence-based differences in the pharmacological agents used to manage sialorrhea in patients with Parkinson's disease (PD).

Material And Methods: The authors searched the databases: MEDLINE via PubMed, EMBASE, Scopus, Web of Science, and Cochrane Library for clinical trials. Unpublished trials were searched on clinicaltrials.

View Article and Find Full Text PDF

This study evaluated surface roughness, color stability, whitening index, and opacity of different types of modeling liquids for resin composite coating after exposure to staining and toothbrushing. Disc-shaped resin composite (Vittra APS, FGM) specimens were fabricated and divided into four groups (n = 10 each): control group, Composite Wetting resin (Ultradent Products), Adper Scotchbond Multipurpose adhesive (3M ESPE), and Adper Universal adhesive (3M ESPE). Surface roughness (Ra) was measured using a rugosimeter, while color stability (∆E00), whitening index (WI), and opacity (%) were measured using a spectrophotometer.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the surrounding and underlying shades' effect on the color adjustment potential (CAP) of a single-shade composite used in a thin layer.

Materials And Methods: Cylinder specimens (1.0 mm thick) were built with the Vittra APS Unique composite, surrounded (dual specimens) or not (simple specimens) by a control composite (shade A1, A2, or A3).

View Article and Find Full Text PDF

Objective: This study evaluated the effect of the supplementary use of the XP-endo Finisher on postoperative endodontic pain.

Methods: This study was a randomized clinical trial with a parallel design. Ninety-two posterior teeth with necrotic pulps and apical periodontitis were instrumented with a single file (Reciproc) in a reciprocating movement followed or not (control) by additional instrumentation with XP-endo Finisher.

View Article and Find Full Text PDF

This study evaluated the effect of surrounded shade and specimens` thickness on the color adjustment potential (CAP) of a single-shade composite. The composite Vittra APS Unique was surrounded (dual specimens) or not (simple specimens) by a control composite (shade A1, A2, or A3). Simple specimens of the control composite were also confectioned.

View Article and Find Full Text PDF

Aim: To evaluate in vitro the whiteness index (WID) and the whiteness index variation (ΔWID), as well as the color stability of stained endodontically treated teeth after bleaching with violet LED (VL) and with hydrogen peroxide 35% (HP) associated or not to VL.

Methods: Twenty-four lower incisors were selected. The color was measured using a spectrophotometer at the following times: baseline, after staining, bleaching, and thermocycling, to determine the whiteness index and variation (WID and ΔWID).

View Article and Find Full Text PDF

Aim: To evaluate the influence of root canal filling quality on periapical lesion status using cone-beam computed tomography (CBCT).

Materials And Methods: The bibliographic search was conducted in electronic databases of PubMed, Embase, Scopus, and Web of Science without restrictions related to the year of publication and language. Inclusion criteria were prospective or retrospective cohort studies that followed periapical pathosis for, at least, 1 year.

View Article and Find Full Text PDF

This study investigated the bleaching effectiveness and the physicochemical effects on enamel of violet light and ozone, associate or not to hydrogen peroxide, compared to 35%-hydrogen peroxide. Enamel-dentin blocks from human molars were randomly allocated to receive one of the following bleaching protocols (n=15): (HP) 35%-hydrogen peroxide, (VL) violet light, (OZ) ozone, the association between hydrogen peroxide with ozone (OZ+HP) or violet light (VL+HP). All protocols were performed in two sessions with a 48h interval.

View Article and Find Full Text PDF

Objectives: This systematic review evaluated the efficacy of the supplementary use of the XP-endo Finisher on bacteria content reduction in the root canal system.

Materials And Methods: studies evaluating the use of the XP-endo Finisher on bacteria content were searched in four databases in July 2020. Two authors independently screened the studies for eligibility.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the effect of interval time after acidic beverage intake and brushing on roughness and hardness of resin composite.

Materials And Methods: Nanofilled resin composites were tested as per interval time (no interval, 15 or 30 minutes) between aging media (isotonic, sports drink) and brushing. Specimens ( = 9) were subjected to three cycles daily for 5 days with immersion in beverage followed by simulated brushing (585 strokes).

View Article and Find Full Text PDF

Objectives: This study assessed the reliability of digital color measurements using images of resin composite specimens captured with a cellphone.

Materials And Methods: The reference color of cylindrical specimens built-up with the use of resin composite (shades A1, A2, A3, and A4) was measured with a portable spectrophotometer (CIELab). Images of the specimens were obtained individually or pairwise (compared shades in the same photograph) under standardized parameters.

View Article and Find Full Text PDF