Purpose: Respiratory-guided computed tomography (CT) typically employs breathing motion surrogates to feed image reconstruction or visual breathing coaching. Our study aimed to assess the impact of table movements and table sag on the breathing curves recorded in four-dimensional (4D) CT and deep-inspiration breath-hold (DIBH) CT.
Methods: For breathing curve measurements, static and dynamic phantom scenarios were used.
Low-dose-rate (LDR) brachytherapy with I-125 seeds is one of the most common primary tumor treatments for low-risk and low-intermediate-risk prostate cancer. This report aimed to present an analysis of single-institution long-term results. We analyzed the treatment outcomes of 119 patients with low- and intermediate-risk prostate cancer treated with LDR brachytherapy at our institution between 2014 and 2020.
View Article and Find Full Text PDFBackground: Interstitial and/or intracavitary brachytherapy is an integral part of the treatment of vaginal cancer Brachytherapy (BT) has shown to improve local control, overall survival (OS) and disease-free survival (DFS). The aim of our study was to analyze the efficacy and safety of brachytherapy in patients with vaginal cancer.
Materials And Methods: Between 2000 and 2023, 27 patients with vaginal cancer in stage FIGO I-III were treated with brachytherapy with or without external beam radiotherapy (EBRT) and simultaneous chemotherapy.
Background: Failure mode and effects analysis (FMEA) is a valuable tool for radiotherapy risk assessment, yet its outputs might be unreliable due to failures not being identified or due to a lack of accurate error rates.
Purpose: A novel incident reporting system (IRS) linked to an FMEA database was tested and evaluated. The study investigated whether the system was suitable for validating a previously performed analysis and whether it could provide accurate error rates to support the expert occurrence ratings of previously identified failure modes.
Objective: There are numerous curative treatment possibilities for prostate cancer. In patients who have undergone rectal extirpation for rectal cancer treatment, curative options are limited due to anatomic changes and previous irradiation of the pelvis. In this analysis, we validate the feasibility of CT-guided transperineal interstitial brachytherapy for this specific scenario.
View Article and Find Full Text PDFPurpose: A prototype infrared camera - cone-beam computed tomography (CBCT) system for tracking in brachytherapy has recently been developed. We evaluated for the first time the corresponding tracking accuracy and uncertainties, and implemented a tracking-based prediction of needles on CBCT scans.
Methods: A marker tool rigidly attached to needles was 3D printed.
Purpose: To investigate geometric and dosimetric inter-observer variability in needle reconstruction for temporary prostate brachytherapy. To assess the potential of registrations between transrectal ultrasound (TRUS) and cone-beam computed tomography (CBCT) to support implant reconstructions.
Methods And Materials: The needles implanted in 28 patients were reconstructed on TRUS by three physicists.
Background And Purpose: Even with most breathing-controlled four-dimensional computed tomography (4DCT) algorithms image artifacts caused by single significant longer breathing still occur, resulting in negative consequences for radiotherapy. Our study presents first phantom examinations of a new optimized raw data selection and binning algorithm, aiming to improve image quality and geometric accuracy without additional dose exposure.
Materials And Methods: To validate the new approach, phantom measurements were performed to assess geometric accuracy (volume fidelity, root mean square error, Dice coefficient of volume overlap) for one- and three-dimensional tumor motion trajectories with and without considering motion hysteresis effects.
Purpose: To enable a real-time applicator guidance for brachytherapy, we used for the first time infra-red tracking cameras (OptiTrack, USA) integrated into a mobile cone-beam computed tomography (CBCT) scanner (medPhoton, Austria). We provide the first description of this prototype and its performance evaluation.
Methods: We performed assessments of camera calibration and camera-CBCT registration using a geometric calibration phantom.
Background And Purpose: The current standard imaging-technique for creating postplans in seed prostate brachytherapy is computed tomography (CT), that is associated with additional radiation exposure and poor soft tissue contrast. To establish a magnetic resonance imaging (MRI) only workflow combining improved tissue contrast and high seed detectability, a deep learning-approach for automatic seed segmentation on MRI-scans was developed.
Material And Methods: Patients treated with I-125 seed brachytherapy received a postplan-CT and a 1.
Purpose: To assess the effects of a workflow for reproducible patient and breast positioning on implant stability during high-dose-rate multi-catheter breast brachytherapy.
Methods: Thirty patients were treated with our new positioning control workflow. Implant stability was evaluated based on a comparison of planning-CTs to control-CTs acquired halfway through the treatment.
Background: CBCT imaging with field of views (FOVs) exceeding the size of scans acquired in the conventional imaging geometry, i.e. with opposing source and detector, is of high clinical importance for many medical fields.
View Article and Find Full Text PDFBackground And Purpose: To assess implant stability and identify causes of implant variations during high-dose-rate multi-catheter breast brachytherapy.
Materials And Methods: Planning-CTs were compared to control-CTs acquired halfway through the treatment for 100 patients. For assessing geometric stability, Fréchet-distance and button-to-button distance changes of all catheters as well as variations of Euclidean distances and convex hulls of all dwell positions were determined.
Purpose: To investigate differences in seed-displacements between the immediate post-implant phase (day 0-1) and the time to post-plan computed tomography (CT) (day 1-30) in seed prostate brachytherapy.
Materials And Methods: Seed positions were identified on the intra-operatively created ultrasound-based treatment plan (day 0) and CT scans of day 1 and 30 for 33 patients. The day 1 (30) seed arrangement was registered onto the day 0 (1) arrangement using a seed-only approach.
Purpose: A novel, mobile 3-in-1 X-ray system featuring radiography, fluoroscopy, and cone-beam computed tomography (CBCT) has been launched for brachytherapy recently. Currently, there is no quality assurance (QA) procedure explicitly applicable to this system equipped with innovative technologies such as dynamic jaws and motorized lasers. We developed a dedicated QA procedure and, based on its performance for a duration of 6 months, provide an assessment of the device's stability over time.
View Article and Find Full Text PDFBackground & Purpose: Four-dimensional computed tomography (4DCT) scans are standardly used for radiotherapy planning of tumors subject to respiratory motion. Based on online analysis and automatic adaption of scan parameters to the patient's individual breathing pattern, a new breathing-controlled 4DCT (i4DCT) algorithm attempts to counteract irregular breathing and thus prevent artifacts. The aim of this study was to perform an initial quality assurance for i4DCT.
View Article and Find Full Text PDFPurpose: To enable a fast and automatic deep learning-based QSM reconstruction of tissues with diverse chemical shifts, relevant to most regions outside the brain.
Methods: A UNET was trained to reconstruct susceptibility maps using synthetically generated, unwrapped, multi-echo phase data as input. The RMS error with respect to synthetic validation data was computed.
Purpose: Seed brachytherapy is a well-established treatment modality for prostate cancer. However, there is still a lack of profound characterizations of seed motions within the prostate. We assessed these dynamics between day 0 and day 30 of brachytherapy.
View Article and Find Full Text PDFJ Appl Clin Med Phys
April 2022
The regular evaluation of imaging performance of computed tomography (CT) scanners is essential for CT quality assurance. For automation of this process, the software QAMaster was developed at the Universitätsklinikum Erlangen, which provides based on CT scans of the CatPhan® 504 (The Phantom Laboratory, Salem, USA) automated image quality analysis and documentation by evaluating CT number accuracy, spatial linearity, uniformity, contrast-noise-ratio, spatial resolution, noise, and slice thickness. Dose assessment is supported by calculations of the weighted computed tomography dose index (CTDI ) and weighted cone beam dose index (CBDI ).
View Article and Find Full Text PDFBackground And Purpose: On-site cone-beam computed tomography (CBCT) has gained in importance in adaptive brachytherapy during recent years. Besides treatment planning, there is increased need particularly for image-guidance during interventional procedures and for image-guided treatment quality assurance (QA). For this purpose, an innovative CBCT device was rolled out at our hospital as the first site worldwide.
View Article and Find Full Text PDFPurpose: A novel, mobile cone-beam computed tomography (CBCT) system for image-guided adaptive brachytherapy was recently deployed at our hospital as worldwide first site. Prior to the device's clinical operation, a profound characterization of its imaging performance was conducted. This was essential to optimize both the imaging workflow and image quality for achieving the best possible clinical outcomes.