Publications by authors named "Andre Begin-Drolet"

Road agency initiatives to reduce traffic-related greenhouse gas emissions are limited by the inability of current experimental methods to assess pavement impacts on vehicle energy consumption. This study addresses this by examining the rolling resistance of a semi-trailer suspension under highway conditions using a precise measurement system with embedded transducers. Data were collected over 174 km of highway, covering various pavement types under mild summer conditions.

View Article and Find Full Text PDF

Background: Obstructive sleep apnea/hypopnea syndrome (OSAHS) is a prevalent condition affecting a substantial portion of the global population, with its prevalence increasing over the past 2 decades. OSAHS is characterized by recurrent upper airway (UA) closure during sleep, leading to significant impacts on quality of life and heightened cardiovascular and metabolic morbidity. Despite continuous positive airway pressure (CPAP) being the gold standard treatment, patient adherence remains suboptimal due to various factors, such as discomfort, side effects, and treatment unacceptability.

View Article and Find Full Text PDF

This study describes the function, optimization, and demonstration of a new class of passive, low-cost microfluidic flow meters based on birefringent chitosan biomembranes analyzed by polarized microscopy. We subjected the membrane to dynamic flow conditions while monitoring the real-time response of its optical properties. We obtained figures of merit, including the linear response operating range (0 to 65 μL min), minimum response time (250 ms), sensitivity (2.

View Article and Find Full Text PDF

A prominent obstacle in scaling up tissue engineering technologies for human applications is engineering an adequate supply of oxygen and nutrients throughout artificial tissues. Sugar glass has emerged as a promising 3D-printable, sacrificial material that can be used to embed perfusable networks within cell-laden matrices to improve mass transfer. To characterize and optimize a previously published sugar ink, we investigated the effects of sucrose, glucose, and dextran concentration on the glass transition temperature (), printability, and stability of 3D-printed sugar glass constructs.

View Article and Find Full Text PDF

Microfluidics has emerged as a powerful technology with diverse applications in microbiology, medicine, chemistry, and physics. While its potential for controlling and studying chemical reactions is well recognized, the extraction and analysis of useful chemical information generated within microfluidic devices remain challenging. This is mainly due to the limited tools available for measurements of chemical reactions.

View Article and Find Full Text PDF

We present a generalizable fabrication method for a new class of analytical devices that merges virtually any microfluidic design with high-sensitivity on-chip attenuated total reflection (ATR) sampling using any standard Fourier transform infrared (FTIR) spectrometer. Termed "spectIR-fluidics", a major design feature is the integration of a multi-groove silicon ATR crystal into a microfluidic device, compared with previous approaches in which the ATR surface served as a structural support for the entire device. This was accomplished by the design, fabrication, and aligned bonding of a highly engineered ATR sensing layer, which con```tains a seamlessly embedded ATR crystal on the channel side and an optical access port that matched the spectrometer light path characteristics at the device exterior.

View Article and Find Full Text PDF

Hydrogels are widely used as cell scaffolds in several biomedical applications. Once implanted in vivo, cell scaffolds must often be visualized, and monitored overtime. However, cell scaffolds appear poorly contrasted in most biomedical imaging modalities such as magnetic resonance imaging (MRI).

View Article and Find Full Text PDF

Every year, thousands of aortic valve replacements must take place due to valve diseases. Tissue-engineered heart valves represent promising valve substitutes with remodeling, regeneration, and growth capabilities. However, the accurate reproduction of the complex three-dimensional (3D) anatomy of the aortic valve remains a challenge for current biofabrication methods.

View Article and Find Full Text PDF

We present a novel spectroscopy accessory that can easily convert any Fourier transform infrared (FTIR) spectrometer into a fully automated mapping and assaying system. The accessory uses a multiridge attenuated total reflection (ATR) wafer as the sensing element coupled with a moving aperture that is used to select the regions of interest on the wafer. In this demonstration, the accessory is combined with a series of parallel micropatterned channels, which are positioned co-linear with the light-coupling ridges on the opposite side of the ATR wafer.

View Article and Find Full Text PDF

Transplantation of hydrogel-encapsulated pancreatic islets is a promising long-term treatment for type 1 diabetes that restores blood glucose regulation while providing graft immunoprotection. Most human-scale islet encapsulation devices that rely solely on diffusion fail to provide sufficient surface area to meet islet oxygen demands. Perfused macroencapsulation devices use blood flow to mitigate oxygen limitations but increase the complexity of blood-device interactions.

View Article and Find Full Text PDF

Purpose: Accurately reproducing physiological and time-varying variables in cardiac bioreactors is a difficult task for conventional control methods. This paper presents a new controller based on a genetic algorithm for the control of a cardiac bioreactor dedicated to the study and conditioning of heart valve substitutes.

Methods: A multi-objective genetic algorithm was designed to obtain an accurate simultaneous reproduction of physiological periodic time functions of the three most relevant variables characterizing the blood flow in the aortic valve.

View Article and Find Full Text PDF

A fully automated linear scanning attenuated total reflection (ATR) accessory is presented for Fourier transform infrared (FTIR) spectroscopy. The approach is based on the accurate displacement of a multibounce ATR crystal relative to a stationary infrared beam. To ensure accurate positioning and to provide a second sample characterization mode, a custom-built microscope was integrated into the system and the computerized work flow.

View Article and Find Full Text PDF

Alginate-based hydrogels are widely used for the development of biomedical scaffolds in regenerative medicine. The use of sugar glass as a sacrificial template for fluidic channels fabrication within alginate scaffolds remains a challenge because of the premature dissolution of sugar by the water contained in the alginate as well as the relatively slow internal gelation rate of the alginate. Here, a new and simple method, based on a sugar glass fugitive ink loaded with calcium chloride to build sacrificial molds, is presented.

View Article and Find Full Text PDF