Background: Uncemented trabecular metal (TM) monoblock tibial components in total knee arthroplasty (TKA) have shown excellent clinical results for up to 10 years. However, these studies were performed in highly specialized units, with few surgeons and often excluding knees with secondary osteoarthritis (OA), severe malalignments and previous surgery. The purpose of this study was to investigate implant survivorship and clinical and radiological outcome of the uncemented TM high-flex posterior stabilized (PS) monoblock tibial component in routine clinical practice.

View Article and Find Full Text PDF

Background And Purpose: Information on outcomes after some modern total ankle replacement (TAR) designs is scarce. We therefore examined outcomes after trabecular metal (TM) TAR in Sweden by use of data from the national registry.

Patients And Methods: On December 31, 2020, 239 primary TM TARs had been reported to the Swedish Ankle Registry.

View Article and Find Full Text PDF

Background: We report the outcomes of a prospective consecutive series of 267 total ankle replacements (TARs) using a new mobile bearing Rebalance® prosthesis.

Methods: Between April 2011 and December 2018, 267 consecutive Rebalance® prostheses were implanted in 255 patients at 3 different centers. Estimated survival curves with 95% confidence intervals were produced with the Kaplan-Meier method.

View Article and Find Full Text PDF

Background and purpose - We have previously reported on the prosthetic survival of total ankle replacements (TAR) in Sweden performed between 1993 and 2010. Few other reports have been published on 5- and 10-year survival rates. Furthermore, there is a lack of long-term outcome data on modern prosthetic designs.

View Article and Find Full Text PDF

Background and purpose - Uncemented monoblock cruciate retaining (CR) trabecular metal (TM) tibial components in total knee arthroplasty (TKA) work well in the long-term perspective in patients ≤ 60 years. Younger persons expect nearly normal knee flexion after TKA, but CR implants generally achieve less knee flexion compared with posterior stabilized (PS) implants. Cemented PS implants have higher revision rate than CR implants.

View Article and Find Full Text PDF

Purpose: To study the pattern of migration and clinical results up to 10 years of uncemented versus cemented fixation of the femoral component in total knee arthroplasty.

Methods: Randomized controlled trial was conducted of 41 patients (23 women, 18 men) under the age of 60 years using radiostereometric analysis.

Results: About two-thirds of the cemented implants and half of the uncemented implants stabilized between 2 and 10 years, while the remainder displayed a small annual increase of maximum total point motion of 0.

View Article and Find Full Text PDF

Background and purpose - Arthrodesis is the most common treatment of severe ankle arthritis. Large studies on the occurrence of re-arthrodesis are few, especially with information in terms of risk. We used the National Swedish Ankle Registry to assess incidence and risk factors for re-arthrodesis.

View Article and Find Full Text PDF

Background and purpose - Total ankle replacement (TAR) is gaining popularity for treatment of end-stage ankle arthritis. Large patient-centered outcome studies are, however, few. Here, we report data from the Swedish Ankle Registry.

View Article and Find Full Text PDF

Bilateral ankle arthrodesis is seldom performed, and results concerning the outcome and satisfaction can only sparsely be found in published studies. We analyzed the data from 35 patients who had undergone bilateral ankle arthrodesis in the Swedish Ankle Registry using patient-reported generic and region-specific outcome measures. Of 36 talocrural arthrodeses and 34 tibio-talar-calcaneal arthrodeses, 6 ankles (9%) had undergone repeat arthrodesis because of nonunion.

View Article and Find Full Text PDF

Background and purpose - Total knee replacement (TKR) in younger patients using cemented components has shown inferior results, mainly due to aseptic loosening. Excellent clinical results have been reported with components made of trabecular metal (TM). In a previous report, we have shown stabilization of the TM tibial implants for up to 5 years.

View Article and Find Full Text PDF

Background: Both total ankle replacement (TAR) and ankle arthrodesis do show some problems in long-term studies. To choose either of these surgical options is a delicate task. There are no randomized studies reported in the literature and no previous studies in which patients constitute the own controls.

View Article and Find Full Text PDF

Background: In cases with total ankle replacement (TAR) failure, a decision between revision TAR and salvage arthrodesis (SA) must be made. In a previous study, we analyzed revision TAR and found low functional outcome and satisfaction. The aims of the current study were to analyze SA concerning failure rate and patient-related outcome measures (PROMs).

View Article and Find Full Text PDF

Background: The Scandinavian Total Ankle Replacement (STAR) has been used widely in Europe and more recently in the United States. We studied the results of the single-coated and the double-coated STAR with long-term follow-up.

Methods: All STARs (n = 324) used in Sweden (first implanted in 1993) were included.

View Article and Find Full Text PDF

Background And Purpose: Clinical results of total knee replacement (TKR) are inferior in younger patients, mainly due to aseptic loosening. Coating of components with trabecular metal (TM) is a new way of enhancing fixation to bone. We have previously reported stabilization of TM tibial components at 2 years.

View Article and Find Full Text PDF

Background And Purpose: There is an ongoing need to review large series of total ankle replacements (TARs) for monitoring of changes in practice and their outcome. 4 national registries, including the Swedish Ankle Register, have previously reported their 5-year results. We now present an extended series with a longer follow-up, and with a 10-year survival analysis.

View Article and Find Full Text PDF

Background And Purpose: Arthrodesis after failed total ankle replacement is complicated and delayed union, nonunion, and shortening of the leg often occur-especially with large bone defects. We investigated the use of a trabecular metal implant and a retrograde intramedullary nail to obtain fusion.

Patients And Methods: 13 patients with a migrated or loose total ankle implant underwent arthrodesis with the use of a retrograde intramedullary nail through a trabecular metal Tibial Cone.

View Article and Find Full Text PDF

Background: There are few studies concerning specific total ankle arthroplasties. This study reports mid-term survival data for the AES prosthesis.

Methods: Ninety-three AES ankle arthroplasties were performed by the senior authors.

View Article and Find Full Text PDF

The optimal mode of femoral fixation in total knee arthroplasty (TKA) remains controversial, especially for the young patient. In a prospective randomised study we compared the magnitude and pattern of the fixation of cemented versus uncemented femoral components during 2 years in patients younger than 60 years. Forty-one knees in 41 patients were randomised to receive a NexGen (Zimmer, Warsaw, USA) cruciate-retaining TKA with either a cemented or an uncemented non HA-coated femoral component.

View Article and Find Full Text PDF

Background: Whether or not ankles can be replaced with reasonable safety has been the subject of debate. We present the results of a nationwide series of total ankle arthroplasties.

Patients And Methods: All Swedish hospitals that implant or have implanted modern three-component ankle prostheses reported demographic data and date of index and revision surgery to a central register.

View Article and Find Full Text PDF

Unlabelled: Fixation of the tibial component in total knee arthroplasty in younger patients remains controversial. We evaluate the results of three different types of fixation of the Profix total knee arthroplasty in a randomized controlled trial of 97 consecutive knees (85 patients) with osteoarthrosis or inflammatory arthritis with 2-year followup of all patients. We randomized patients to three different types of fixation of the tibial component: cemented, uncemented (HA coated) with screws, or uncemented (HA coated) without screws.

View Article and Find Full Text PDF

Unlabelled: Mobile bearings were introduced to improve wear and knee kinematics. By uncoupling the forces generated at the articulation from the implant-bone interface this would, theoretically, also improve the fixation of the implant to bone. We did this study to evaluate whether mobile bearings improve the fixation of the tibial component to bone.

View Article and Find Full Text PDF