This work involves the electrochemical study of the interaction of SYBR Green I (SG) with native DNA using differential pulse voltammetry at a carbon paste electrode (CPE) and alternating current voltammetry at a hanging mercury drop electrode (HMDE). At the CPE the peak current intensity at 1.0 V decreased by increasing the concentration of SG.
View Article and Find Full Text PDFA simple, sensitive method for determining free cyanides is described. The assay is based on automated gas diffusion of the analyte using sequential injection analysis (SIA) coupled to amperometric detection on a silver working electrode. The effects of varying several parameters affecting the analytical procedure (including the flow rates of the donor and acceptor streams, the concentrations of the reagents and the sample volumes) were studied.
View Article and Find Full Text PDFThe principle of sequential injection (SI) was exploited to develop a fully automated pre-column derivatization procedure combined on-line to liquid chromatography (LC). Using SI-LC derivatization 14 amino acids were determined fluorimetrically in pharmaceuticals with o-phthaldialdehyde (OPA) as the derivatization reagent. The SI system was used for the handling of samples and reagents, on-line mixing and introduction to the LC injection system.
View Article and Find Full Text PDFAmplicons corresponding to the GC-rich p53 exon 5 and its analogues, synthesized by substituting 60% of cytosine by 5-methyl-cytosine, or 60% of guanosine by inosine and GC-poor p53 exon 6 were synthesized and investigated electrochemically, in the presence and absence of proflavine, by differential pulse voltammetry (DPV). Incorporation of base analogues and the thermal stability of the resulting amplicons were tested in the presence of a fluorescent probe (Sybr-Green). Peak current at 1.
View Article and Find Full Text PDFJ Biochem Biophys Methods
March 2007
Sample preparation (SP) is an integral and important part of an analytical process. Lately, SP has been the topic of increased interest in research and development of novel advanced technologies. Major needs in this aspect are miniaturization, automation, and enrichment.
View Article and Find Full Text PDFJ Chromatogr A
November 2006
The on-line coupling of sequential injection analysis (SIA) and capillary electrophoresis (CE) via an in-line injection valve is presented. The SIA system is used for automated derivatization of amino acids and peptides. Dichlorotriazinylaminofluorescein serves as the derivatization agent, thus enabling sensitive laser-induced fluorescence detection of the derivatized analytes.
View Article and Find Full Text PDFA sequential injection analysis (SIA) manifold was incorporated with a monolithic strong anion-exchanger disk for on-line drug-protein interaction studies. The antibiotic ciprofloxacin (CF) was selected as a model drug compound. The separation principle was based on the strong retention of bovine serum albumin (BSA) on the monolithic strong anion-exchanger and the liberation/release of the free form of the drug.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
September 2004
The principle of sequential injection analysis (SIA) was exploited to develop a rapid fully automated and efficient pre-column derivatization procedure coupled on-line to liquid chromatography (HPLC). Using the SIA-HPLC derivatization protocol gamma-aminobutyric acid (GABA) was determined fluorimetrically in human biological fluids with o-phthaldialdehyde (OPA) as derivatization reagent and minimum sample pretreatment. A lab-built SIA system was used to handle samples, standard solutions and OPA reagent.
View Article and Find Full Text PDF