Publications by authors named "Anastasi M"

Imaging is used for lymphoma detection, Ann Arbor/Lugano staging, and treatment response assessment. [F]FDG PET/CT should be used for most lymphomas, including Hodgkin lymphoma, aggressive/high-grade Non-Hodgkin lymphomas (NHL) such as diffuse large B-cell lymphoma, and many indolent/low-grade NHLs such as follicular lymphoma. Apart from these routinely FDG-avid lymphomas, some indolent NHLs, such as marginal zone lymphoma, are variably FDG-avid; here, [F]FDG PET/CT is an alternative to contrast-enhanced CT at baseline and may be used for treatment response assessment if the lymphoma was FDG-avid at baseline.

View Article and Find Full Text PDF
Article Synopsis
  • * This study examines 15 biopsies from patients aged 28-36 to investigate the histological features and protein expression in inactive UCH using light microscopy and immunofluorescence.
  • * Findings suggest that even in inactive UCH, there is moderate biological activity, indicating a potential for reactivation and that the condition may not be completely self-limiting, despite the absence of detectable cartilage islands.
View Article and Find Full Text PDF

Background & Aims: Transmural healing (TH) is emerging as a potential Crohn's disease (CD) treatment target. Early biological treatment seems to be associated with improved disease outcomes, but its impact on TH remains unclear. We aimed to assess the impact of early biological treatment initiation on TH and its influence on CD prognosis.

View Article and Find Full Text PDF

Purpose: This case report describes the possibility of XEN63 lumen obstruction at the middle of the device and emphasizes the potential to restore its flow using an ab-externo revision technique involving a 10-0 nylon suture probe, before considering more aggressive surgical interventions.

Methods: A 55-year-old female with uveitic glaucoma underwent XEN63 implantation but experienced elevated intraocular pressure (IOP) (35 mm Hg) 1 month after the operation, despite medical therapy. A flat bleb, lack of response to medication, yttrium aluminum garnet (YAG) laser treatment, and slit-lamp needling necessitated revision.

View Article and Find Full Text PDF

Assessing the response to oncological treatments is paramount for determining the prognosis and defining the best treatment for each patient. Several biomarkers, including imaging, can be used, but standardization is fundamental for consistency and reliability. Tumor response evaluation criteria have been defined by international groups for application in pharmaceutical clinical trials evaluating new drugs or therapeutic strategies.

View Article and Find Full Text PDF

Purpose: Patient-specific protocol optimisation in abdomino-pelvic Computed Tomography (CT) requires measurement of body habitus/size (BH), sensitivity-specificity (surrogates image quality (IQ) metrics) and risk (surrogates often dose quantities) (RD). This work provides an updated inventory of metrics available for each of these three categories of optimisation variables derivable directly from patient measurements or images. We consider objective IQ metrics mostly in the spatial domain (i.

View Article and Find Full Text PDF

Unlabelled: Over the past few years, artificial intelligence (AI) has emerged as a powerful tool used to efficiently automate several tasks across multiple domains. Sleep medicine is perfectly positioned to leverage this tool due to the wealth of physiological signals obtained through sleep studies or sleep tracking devices and abundance of accessible clinical data through electronic medical records. However, caution must be applied when utilizing AI, due to intrinsic challenges associated with novel technology.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate how effective CT-guided drainage (CTD) is for managing fluid collections after liver transplants, looking at technical success, clinical outcomes, and complications.
  • Over a period from 2005 to 2020, 91 drain placements were conducted with a technical success rate of 93.4%, while clinical success rates varied, showing a notable recovery in inflammatory markers within days.
  • The findings suggest that CTD is highly effective, requiring no surgical revisions in most cases, and highlighted a reduction in radiation exposure during procedures in the later years of the study.
View Article and Find Full Text PDF

Objectives: To assess radiologists' current use of, and opinions on, structured reporting (SR) in oncologic imaging, and to provide recommendations for a structured report template.

Materials And Methods: An online survey with 28 questions was sent to European Society of Oncologic Imaging (ESOI) members. The questionnaire had four main parts: (1) participant information, e.

View Article and Find Full Text PDF

Objectives: To present the results of a survey on the assessment of treatment response with imaging in oncologic patient, in routine clinical practice. The survey was promoted by the European Society of Oncologic Imaging to gather information for the development of reporting models and recommendations.

Methods: The survey was launched on the European Society of Oncologic Imaging website and was available for 3 weeks.

View Article and Find Full Text PDF

Purpose: The purpose of the study is to show the excellent anatomical result of the inverted flap-assisted technique with platelet-rich plasma under air for retinitis pigmentosa complicated with macular hole.

Methods: A 32-year-old woman, previously diagnosed with retinitis pigmentosa, was referred to our department complaining of decreased central vision in her left eye for 4 weeks. At the time of presentation, the optical coherence tomography and fundoscopy examination showed the presence of a macular hole of 620 μ m in diameter.

View Article and Find Full Text PDF

Purpose: To assess accuracy, the frequency of hemorrhagic complications and computed tomography (CT) radiation dose parameters in pediatric patients undergoing landmark-guided external ventricular drain (EVD) placement in an emergency setting.

Methods: Retrospective analysis comprised 36 EVD placements with subsequent CT control scans in 29 patients (aged 0 to 17 years) in our university hospital from 2008 to 2022. The position of the EVD as well as the presence and extension of bleeding were classified according to previously established grading schemes.

View Article and Find Full Text PDF

Purpose: To analyze the objective and subjective visual performances of a new hybrid refractive/aspheric extended depth of focus (EDOF) intraocular lens (IOL).

Methods: In this monocentric prospective study patients with bilateral cataracts underwent cataract surgery and were implanted with a Lucidis IOL (SAV-IOL SA, Neuchâtel, Switzerland) in both eyes, 1 week apart from each other. At 3 months from implantation postoperative evaluations included monocular and binocular uncorrected and distance-corrected distant (4 m), intermediate (80 cm, 67 cm) and near (40 cm) visual acuities (UDVA/DCVA, UI80-67VA/DCI80-67VA, UNVA/DCNVA), binocular defocus curves, halometry, contrast sensitivity and objective quality-of-vision measurements.

View Article and Find Full Text PDF

Purpose: To assess the technical (TS) and clinical success (CS) of CT fluoroscopy-guided drainage (CTD) in patients with symptomatic deep pelvic fluid collections following colorectal surgery.

Methods: A retrospective analysis (years 2005 to 2020) comprised 43 drain placements in 40 patients undergoing low-dose (10-20 mA tube current) quick-check CTD using a percutaneous transgluteal ( = 39) or transperineal ( = 1) access. TS was defined as sufficient drainage of the fluid collection by ≥50% and the absence of complications according to the Cardiovascular and Interventional Radiological Society of Europe (CIRSE).

View Article and Find Full Text PDF

Purpose: Calculation of the Size Specific Dose Estimate (SSDE) requires accurate delineation of the skin boundary of patient CT slices. The AAPM recommendation for SSDE evaluation at every CT slice is too time intensive for manual contouring, prohibiting real-time or bulk processing; an automated approach is therefore desirable. Previous automated delineation studies either did not fully disclose the steps of the algorithm or did not always manage to fully isolate the patient.

View Article and Find Full Text PDF

To evaluate the technical outcome, clinical success, and safety of low-milliampere CT fluoroscopy (CTF)-guided percutaneous drain (PD) placement in patients with lymphoceles following radical prostatectomy (RP) with pelvic lymph node dissection (LND). This retrospective analysis comprised 65 patients with PD placement in lymphoceles following RP under low-milliampere CTF guidance. Technical and clinical success were evaluated.

View Article and Find Full Text PDF

Background: Treatment monitoring in metastatic colorectal cancer (mCRC) relies on imaging to evaluate the tumour burden. Response Evaluation Criteria in Solid Tumors provide a framework on reporting and interpretation of imaging findings yet offer no guidance on a standardised imaging protocol tailored to patients with mCRC. Imaging protocol heterogeneity remains a challenge for the reproducibility of conventional imaging end-points and is an obstacle for research on novel imaging end-points.

View Article and Find Full Text PDF

Purpose: The aim of this study was to investigate the outcome of the meniscus-shaped stromal lenticule addition keratoplasty (MS-SLAK) in corneal regularization and thickness.

Methods: Patients waiting for deep anterior lamellar keratoplasty for advanced keratoconus with an intolerance to contact lenses (CLs) underwent the MS-SLAK procedure by FSL 80 kHz ablation (VICTUS, Technolas Perfect Vision, DE). Customized positive meniscus-shaped stromal lenticules were obtained and implanted.

View Article and Find Full Text PDF

Objectives: To explore radiologists' opinions regarding the shift from in-person oncologic multidisciplinary team meetings (MDTMs) to online MDTMs. To assess the perceived impact of online MDTMs, and to evaluate clinical and technical aspects of online meetings.

Methods: An online questionnaire including 24 questions was e-mailed to all European Society of Oncologic Imaging (ESOI) members.

View Article and Find Full Text PDF

Objectives: Early tumor shrinkage (ETS) quantifies the objective response at the first assessment during systemic treatment. In metastatic colorectal cancer (mCRC), ETS gains relevance as an early available surrogate for patient survival. The aim of this study was to increase the predictive accuracy of ETS by using semi-automated volumetry instead of standard diametric measurements.

View Article and Find Full Text PDF

Purpose: The purpose of this study is to examine the effects of scribe use on physicians, nurses, and patients in an orthopaedic sports medicine clinic.

Methods: Surveys containing validated outcome measures relating to physician well-being and workplace satisfaction, among other variables, were used to assess the influence of medical scribes on clinic function. These surveys were collected for 8 months from all patients, nurses, and orthopaedic surgeons working in one orthopaedic sports medicine clinic.

View Article and Find Full Text PDF

The aim of this prospective explorative study was to evaluate the safety and the effectiveness of topical polyvinylpyrrolidone-iodine (PVP-I) administered during the time-to-results period for pathogen identification and susceptibility testing in patients with infectious keratitis (IK). A corneal swab (CS) for antimicrobial evaluation was performed at enrollment (T0) and topical 0.66%-PVP-I was administered until the laboratory results were available (T1).

View Article and Find Full Text PDF

The spleen is often involved in malignant lymphoma, which manifests on CT as either splenomegaly or focal, hypodense lymphoma lesions. This study aimed to investigate the diagnostic value of radiomics features of the spleen in classifying malignant lymphoma against non-lymphoma as well as the determination of malignant lymphoma subtypes in the case of disease presence-in particular Hodgkin lymphoma (HL), diffuse large B-cell lymphoma (DLBCL), mantle-cell lymphoma (MCL), and follicular lymphoma (FL). Spleen segmentations of 326 patients (139 female, median age 54.

View Article and Find Full Text PDF

Response evaluation criteria in solid tumours (RECIST) v1.1 are currently the reference standard for evaluating efficacy of therapies in patients with solid tumours who are included in clinical trials, and they are widely used and accepted by regulatory agencies. This expert statement discusses the principles underlying RECIST, as well as their reproducibility and limitations.

View Article and Find Full Text PDF

Circular RNA (circRNA) are a recently discovered class of RNA characterized by a covalently-bonded back-splice junction. As circRNAs are inherently more stable than other RNA species, they may be detected extracellularly in peripheral biofluids and provide novel biomarkers. While circRNA have been identified previously in peripheral biofluids, there are few datasets for circRNA junctions from healthy controls.

View Article and Find Full Text PDF