Introduction: In patients with atrial fibrillation (AF), up to one third have recurrence after a first catheter ablation (CA). Epicardial adipose tissue (EAT) has been considered to be closely related to AF, with a potential role in its recurrence. We aimed to evaluate the association between the volume of EAT measured by cardiac computed tomography (CT) and AF recurrence after CA.
View Article and Find Full Text PDFInt J Cardiol Heart Vasc
April 2024
Introduction: Atrial fibrillation (AF) ablation represents a safe and effective procedure to restore sinus rhythm. The idea that post-procedural AF episodes - during the blanking period - are not considered treatment failure has been increasingly challenged. The E-Patch, a single-use adhesive electrode, facilitates extended continuous ECG monitoring for 120 h.
View Article and Find Full Text PDFFront Cardiovasc Med
November 2023
Background: An ablation catheter and a circular mapping catheter requiring a double transeptal puncture (TSP) for left atrial access have been conventionally used for atrial fibrillation (AF) ablation. Recently, different operators have combined a single transseptal puncture technique with 3D high-density mapping catheters for pulmonary vein isolation (PVI).
Objective: This study aims to compare two strategies, single vs.
J Interv Card Electrophysiol
April 2024
Background: Impaired left atrial (LA) strain predicts atrial fibrillation (AF) recurrence after catheter ablation (CA), but currently there is no cut-off to guide patient selection for CA. Integrated backscatter (IBS) is a promising tool for noninvasive quantification of myocardial fibrosis. The aim of this study was to compare LA strain and IBS between paroxysmal, persistent, and long-standing persistent AF and evaluate their association with AF recurrence after CA.
View Article and Find Full Text PDFObjective: This study aimed to assess whether atrial fibrillation (AF) occurrence or its corresponding daily mean burden (in minutes/day) during the mid to late blanking period after pulmonary vein isolation (PVI), predicts AF recurrence.
Methods: Analysis of consecutive first PVI ablation patients undergoing prolonged electrocardiogram (ECG) monitoring during the second and third months after PVI. The clinical variables, total AF burden, and their relationship with time to recurrence were studied.
Introduction: The outflow tract (OT) regions of the ventricles are a common location of origin for idiopathic ventricular arrhythmias (VA). Non-contact mapping (NCM) with a multi-electrode balloon catheter Ensite-Array enables three-dimensional reconstruction of the geometry of the cardiac chambers and accurate mapping of the propagation map, based on a single beat analysis, facilitating the ablation and contributing procedure success.
Objective: Assessment of the feasibility and long-term outcomes following NCM-guided OT VA ablation.
Aims: The present study analysed the patterns of physical activity pre-, during and post-lockdown measures for COVID-19 pandemic in patients with chronic heart failure (CHF) and cardiac implantable electronic devices (CIED) under remote monitoring (RM), and assessed the physical activity patterns during these periods.
Methods: The raw data from 95 patients with CHF (age 67,7 15,1 years, 71,5% male) corresponding to 2238 RM transmissions of the Medtronic Carelink™ network platform was obtained. The physical exercise profiles and the impact of the lockdown measures on the physical behaviour during and after the measures were analysed.
Introduction: Implantable cardioverter-defibrillator (ICD) monitoring zones (MZ) provide passive features that do not interfere with the functioning of active treatment zones. However, it is not known for certain whether programming an MZ affects arrhythmia detection by the ICD. The aim of the present study is to assess the clinical relevance of MZ in a population of patients with ICDs.
View Article and Find Full Text PDFPurpose: Recurrence of atrial fibrillation (AF) after catheter ablation is common, being clinically relevant to identify predictors of recurrence. The left atrial appendage (LAA) role as an AF trigger is scarcely explored. Our aim was to identify if LAA volume is an independent predictor of AF recurrence after catheter ablation.
View Article and Find Full Text PDFAims: There are conflicting data regarding the clinical benefits of device-based remote monitoring (RM). We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICDs).
Methods: We assessed the incidence of adverse cardiac events, overall mortality and device therapy efficacy and safety in a propensity score-matched cohort of patients under RM compared to patients under conventional follow-up.
Aims: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD).
View Article and Find Full Text PDFIntroduction: Left ventricular reverse remodeling (LVRR), defined as reduction of end-diastolic and end-systolic dimensions and improvement of ejection fraction, is associated with the prognostic implications of cardiac resynchronization therapy (CRT). The time course of LVRR remains poorly characterized. Nevertheless, it has been suggested that it occurs ≤6 months after CRT.
View Article and Find Full Text PDF