Objective: To assess the agreement in detecting and monitoring occlusal caries over thirty months using conventional visual and radiographic assessment and an intraoral scanner system which supports automated caries scoring.
Methods: Ninety-one young participants aged 12-19 years were included in the study. All occlusal surfaces were examined visually, radiographically (when indicated), and scanned with the TRIOS 4 intraoral scanner.
The aim of this study was to compare the assessment of tooth wear performed on digital models with the one conducted at the clinical examination. Seventy-eight volunteers (29 males and 49 females, age range 20-30 years) with at least 24 teeth, normal oral function, and a neutral transverse relationship were examined. During the clinical examination, dental wear was registered according to the Basic Erosive Wear Examination (BEWE) index.
View Article and Find Full Text PDFObjectives: To examine the dimensional changes of endodontic sealers during 18 months using three-dimensional (3D) surface scanning and subtraction radiography in a novel in vitro sealer-extrusion model.
Material And Methods: Fifty endodontically instrumented acrylic teeth were randomly allocated to five groups (n = 10) filled with Apexit Plus, AH Plus, BioRoot RCS, TubliSeal EWT, and gutta-percha (control). Freshly mixed sealers were intentionally extruded during obturation.
Biomater Investig Dent
September 2022
Purpose: To evaluate the marginal and internal fit of lithium disilicate and zirconia crowns using two optical coherence tomography (OCT) systems in order to estimate inter-system variations.
Materials And Methods: Ten lithium disilicate and 10 cubic stabilized zirconia crowns were placed on prepared artificial teeth without cement. Marginal discrepancy and internal cement gap of the crowns were assessed on images obtained using a swept source OCT (SS-OCT) and a spectral domain OCT (SD-OCT).
The use of 3D intraoral scanners (IOS) and software that can support automated detection and objective monitoring of oral diseases such as caries, tooth wear or periodontal diseases, is increasingly receiving attention from researchers and industry. This study clinically validates an automated caries scoring system for occlusal caries detection and classification, previously defined for an IOS system featuring fluorescence (TRIOS 4, 3Shape TRIOS A/S, Denmark). Four algorithms (ALG1, ALG2, ALG3, ALG4) are assessed for the IOS; the first three are based only on fluorescence information, while ALG4 also takes into account the tooth color information.
View Article and Find Full Text PDFObjectives: To assess the validity of an intraoral scanner system featuring near-infrared (NIR) transillumination to aid the detection of proximal caries lesions, and to compare the diagnostic performance of this system with that of conventional caries detection methods and with that of an intraoral camera featuring NIR transillumination (DIAGNOcam).
Methods: Ninety-five permanent posterior teeth were examined using a prototype tip functioning with TRIOS 4 intraoral scanner system (3Shape TRIOS A/S, Denmark) and emitting NIR light, DIAGNOcam, and visual and radiographic examination employing ICDAS criteria. One or two approximal surfaces per tooth, sound or with caries lesions at different stages, were examined (N=158).
Objectives: To develop an automated fluorescence-based caries scoring system for an intraoral scanner and totest the performance of the system compared to state-of-the-art methods.
Methods: Seventy-three permanent posterior teeth were scanned with a three-dimensional (3D) intraoral scanner prototype which emitted light at 415 nm. An overlay representing the fluorescence signal from the tissue was mapped onto 3D models of the teeth.
Objectives: To assess the feasibility of detecting and monitoring early erosive tooth wear using a 3D intraoral scanner (IOS) aided by specific software.
Methods: Extracted sound permanent teeth were assembled in two shortened artificial dental arches and scanned at different intervals with an IOS (3Shape TRIOS® 3) before and after an erosion/abrasion protocol (i.e.
Biomater Investig Dent
December 2019
Adhesion and marginal adaptation of a claimed bioactive restorative material (ACTIVA BioACTIVE Restorative) to human teeth were compared with those of a resin-modified glass ionomer cement (Fuji II LC) and a control resin composite (Ceram X Mono). Shear bond strength and marginal adaptation to enamel and dentine were assessed after no pretreatment of the hard tissues or after etching with phosphoric acid (ACTIVA BioACTIVE Restorative and Ceram X Mono) or polyacrylic acid (Fuji II LC). For ACTIVA BioACTIVE Restorative, the effect of applying a self-etch adhesive (Xeno Select, Dentsply Sirona) was also investigated.
View Article and Find Full Text PDFObjective: To systematically review the quality of evidence of available in vitro solubility studies on endodontic sealers according to prespecified evidence criteria.
Material And Methods: This systematic review was based on the PRISMA guidelines and the AMSTAR measurement tool. A systematic duplicate search of the literature on endodontic sealer solubility studies was conducted in PubMed and Embase databases (until 18 October 2017).
Background: The potential of non-invasive optical coherence tomography (OCT) as a tool for assessment of fit of indirect reconstructions is not fully explored.
Objectives: The objectives were to investigate the feasibility and validity of OCT, and to measure the internal and marginal fit of acrylic bridges fabricated using direct and indirect digitalisation.
Methods: The accuracy of the employed swept source OCT (wavelength: 1310 nm) was assessed by comparing with an object with known dimensions.
Objective: To investigate the relationship between physicochemical interactions of resin luting cements with dentine and retention of fibre posts in root canals.
Methods: Retention of fibre posts (RelyX Fiber Post) was assessed by the pull-out method. The diffusion zone of the cements and their chemical interaction with dentine were estimated by micro-Raman spectroscopy.
ACS Appl Mater Interfaces
March 2018
Hydrogen dynamics in a time range from hundreds of femtoseconds to nanoseconds can be directly analyzed using neutron spectroscopy, where information on the inelastic and quasi-elastic scattering, hereafter INS and QENS, can be obtained. In this study, we applied these techniques to understand how the nanoscale mobility of the aqueous solution of polyacrylic acid (PAA) used in conventional glass ionomer cements (GICs) changes under confinement. Combining the spectroscopic analysis with calorimetric results, we were able to separate distinct motions within both the liquid and the GICs.
View Article and Find Full Text PDFStatement Of Problem: Despite the increasing demand for a digital workflow in the fabrication of indirect restorations, information on the accuracy of the resulting definitive casts is limited.
Purpose: The purpose of this in vitro study was to compare the accuracy of definitive casts produced with digital scans and conventional impressions.
Material And Methods: Chamfer preparations were made on the maxillary right canine and second molar of a typodont.
Background: Cobalt release from dental prostheses has been shown to elicit allergic reactions in cobalt-allergic patients. It is therefore important to investigate whether these prostheses are possible sources of sensitization.
Objectives: To assess (i) cobalt release from dental prostheses and (ii) allergic reactions to components of dental prostheses, and (iii) to investigate the oral mucosa for inflammation 1-5 years after insertion of the prostheses.
Objective: To investigate the use of a three-dimensional (3D) digital scanning method in determining the accuracy of the wear performance parameters of resin-based composites (RBCs) determined using a two-dimensional (2D) analogue methodology following in-vitro testing in an Academisch Centrum for Tandheelkunde Amsterdam (ACTA) wear machine.
Methods: Specimens compatible with the compartments of the ACTA wear machine specimen wheel (n=10) were prepared from one commercial and four experimental RBCs. The RBC specimens were rotated against an antagonist wheel in a food-like slurry for 220,000 wear cycles.
The development of dental materials with improved properties and increased longevity can save costs and minimize discomfort for patients. Due to their good biocompatibility, glass ionomer cements are an interesting restorative option. However, these cements have limited mechanical strength to survive in the challenging oral environment.
View Article and Find Full Text PDFPurpose: To assess in situ the enamel mineralization level and susceptibility to coffee staining after in-office bleaching.
Materials And Methods: Thirty-six human dental fragments assembled into intraoral devices were bleached with 35% hydrogen peroxide and treated as follows: (group 1) no contact with coffee; (group 2) immersion in a coffee solution for 30 minutes daily for 7 days, starting 1 week after bleaching; and (group 3) immersion in a coffee solution for 30 minutes daily for 14 days, starting immediately after bleaching. Enamel mineralization and color were assessed before bleaching (T1), immediately after bleaching (T2), and after 7 (T3) and 14 days (T4).
Objective: To investigate how the modulus of elasticity of resin composites influences marginal quality in restorations submitted to thermocyclic and mechanical loading.
Methods: Charisma, Filtek Supreme XTE and Grandio were selected as they were found to possess different moduli of elasticity but quite similar polymerization contraction. MOD cavities (n=30) were prepared in extracted premolars, restored and then subjected to thermocyclic and mechanical loading.
Objectives: To investigate the effect of prolonged chemical challenges on colour stability, staining susceptibility, and roughness of a silorane composite material when compared to methacrylate-based composites.
Methods: Initial colour and roughness were registered for specimens fabricated from methacrylate or silorane composites. Specimens were individually stored at 37°C in 0.
The aim of this cross-sectional study was to assess the factors associated with the impact of oral health on the quality of life in a sample of 504 Brazilian independent elderly. Data collection included oral examinations and structured interviews. The simplified form of the Oral Health Impact Profile (OHIP-14) was used to measure OHRQoL.
View Article and Find Full Text PDFThe purpose of this study was to provide the physicochemical interactions at the interfaces between two commercial etch-&-rinse adhesives and human dentin in a simulated moist bond technique. Six dentin specimens were divided into two groups (n=3) according to the use of two different adhesive systems: (a) 2-hydroxyethylmethacrylate (HEMA) and 4-methacryloxyethyl trimellitate anhydrate (4-META), and (b) HEMA. The Fourier transform infrared photoacoustic spectroscopy was performed before and after dentin treatment with 37% phosphoric acid, with adhesive systems and also for the adhesive systems alone.
View Article and Find Full Text PDFObjective. To investigate the accuracy of dies obtained from single-step and 2-step double-mix impressions. Material and Methods.
View Article and Find Full Text PDF