This study elucidated the radiation response characteristics of a Gafchromic radiochromic film subjected to low photon doses of ≤50 mSv, which corresponds to the annual whole body effective dose limit for radiation workers in Canada. Radiochromic films are investigated for possible use as a complementary tool for the Canadian Armed Forces that can be worn in addition to their existing personal dosimetry to quickly assess personal radiation dose received from radiological hazards without reliance on electronics. The films were exposed to varying photon energies emanating from x-ray generators and radioisotopes, specifically cesium-137, cobalt-60, and americium-241.
View Article and Find Full Text PDFThis work investigates the low photon radiation dose (≤50 mSv) response of commercially available radiochromic films as a potential field dosimeter that could be used by the Canadian Armed Forces to complement their existing personal radiation dosimeters. The films were exposed to various photon energies from x-ray devices and radioisotopes (cesium-137, cobalt-60, and americium-241), and their radiation signal was read using three methods: net optical density, UV/visible spectroscopy, and Fourier transform infrared spectroscopy. A complimentary film dosimeter for field usage should, for military use, display a visual color change and detect doses ≤50 mSv.
View Article and Find Full Text PDFAim: Cancer treatments with radiation present a challenging physical toll for patients, which can be justified by the potential reduction in cancerous tissue with treatment. However, there remain patients for whom treatments do not yield desired outcomes. Radiomics involves using biomedical images to determine imaging features which, when used in tandem with retrospective treatment outcomes, can train machine learning (ML) classifiers to create predictive models.
View Article and Find Full Text PDFObjectives: Lanthanum (La) retention in bone has been shown to occur in individuals who are orally administered lanthanum carbonate (LaC), a drug to treat hyperphosphatemia. The breakdown of LaC in the gastrointestinal tract into La and carbonate ions results in residual quantities of La being deposited in bone. We previously reported on a non-invasive x-ray fluorescence (XRF) system that was developed to quantify bone La concentrations and applied it to a series of excised cadaver tibiae.
View Article and Find Full Text PDFPurpose: The current magnetic resonance imaging-computed tomography (MRI-CT) fusion-based workflow for postimplant dosimetry of low-dose-rate (LDR) prostate brachytherapy takes advantage of the superior soft tissue contrast of MRI, but still relies on CT for seed visualization and detection. Recently an MR-only workflow has been proposed that employs standard MR sequences and visualizes conventional implanted seed with positive contrast solely through MR postprocessing. In this work, the novel MR-only based workflow is compared with the clinical CT-MRI fusion approach.
View Article and Find Full Text PDFObjectives: Lanthanum (La) and gadolinium (Gd) are known to deposit in bone of exposed populations, namely those who are orally administered lanthanum carbonate (LaC, La(CO)) or are injected with Gd-based contrast agents, respectively. In this work, bone La and Gd concentrations from the environment and diet were measured using x-ray fluorescence in ten post-mortem human tibiae. As a secondary objective, bone barium (Ba) and iodine concentrations were estimated.
View Article and Find Full Text PDFPurpose: The lack of positive contrast from brachytherapy seeds in conventional MR images remains a major challenge toward an MRI-only workflow for postimplant dosimetry of low-dose-rate brachytherapy. In this work, the feasibility of our recently proposed MRI-only workflow in clinically relevant scenarios is investigated and the necessary modifications in image acquisition and processing pipeline are proposed for transition to the clinic.
Methods And Materials: Four prostate phantoms with a total of 321 I-125 implanted dummy seeds and three patients with a total of 168 implanted seeds were scanned using a gradient echo sequence on 1.
Purpose: In vivo x-ray fluorescence is a non-invasive analytical technique for determining trace and toxic element exposures. In this work we measure the dose for a portable handheld x-ray system (pXRF).
Materials And Methods: We used EBT3 radiochromic film calibrated with a clinical orthovoltage unit for absolute dose measurement.
Magnetic resonance-guided radiation therapy (MR-GRT) offers great potential to improve radiation treatment outcomes by providing more accurate and patient-tailored therapy. Despite superior soft tissue contrast in MRI, one of the challenges towards MRI-only workflows is that the process often requires some sort of 'MR-invisible' metal-based devices. In this study, the feasibility of quantitative susceptibility mapping (QSM) for visualization of some MR-invisible radiation therapy devices was studied.
View Article and Find Full Text PDFBackground And Purpose: Permanent seed brachytherapy is an established treatment option for localized prostate cancer. Currently, post-implant dosimetry is performed on CT images despite challenging target delineation due to limited soft tissue contrast. This work aims to develop an MRI-only workflow for post-implant dosimetry of prostate brachytherapy seeds.
View Article and Find Full Text PDFBackground: The clinical paradigm for spinal tumors with epidural involvement is challenging considering the rigid dose tolerance of the spinal cord. One effective approach involves open surgery for tumor resection, followed by stereotactic body radiotherapy (SBRT). Resection extent is often determined by the neurosurgeon's clinical expertise, without considering optimal subsequent post-operative SBRT treatment.
View Article and Find Full Text PDFPurpose: Dual-energy X-ray absorptiometry (DXA) is the gold standard technique to measure areal bone mineral density (aBMD) for the diagnosis of osteoporosis. Because DXA relies on the attenuation of photon to estimate aBMD, deposition of bone-seeking metallic elements such as strontium, lead, and aluminum that differ in atomic numbers from calcium can cause inaccurate estimation of aBMD. Quantitative ultrasound (QUS) is another technique available to assess bone health by measuring broadband ultrasound attenuation (BUA), speed of sound (SOS), and an empirically derived quantity called stiffness index (SI).
View Article and Find Full Text PDFObjective: Lanthanum (La) is commonly used in phosphate binders in the form of lanthanum carbonate in patients with end-stage kidney disease undergoing hemodialysis treatments. With this administration, there is the potential for La storage in the body with bone being the main site of concern. However, the long-term effects of residual La in the body on bone health are not yet known.
View Article and Find Full Text PDFObjective: The calibration of in vivo x-ray fluorescence systems of bone strontium quantification, based on I excitation, is dependent on a coherent normalization procedure. Application of this procedure with the use of plaster of Paris (poP) as a phantom material requires the application of a coherent conversion factor (CCF) to make the calibration functions transferable between the phantom material and human bone. In this work we evaluate, with the use of Monte Carlo simulation, the potential benefit of employing a newly developed hydroxyapatite phantom material into the calibration protocol.
View Article and Find Full Text PDFPurpose: Bone quantity, as determined by the current gold standard, dual energy X-ray absorptiometry (DXA), through measured areal bone mineral density (aBMD), is subject to positive biases if bone strontium levels are high. This is of particular concern for populations administered strontium-based compounds for the treatment of osteoporosis. This study investigated the dependence of bone mineral density (BMD) determinations, and associated ultrasound-determined indices, obtained by quantitative ultrasound (QUS), on bone strontium content using a new generation of trabecular bone-mimicking phantoms.
View Article and Find Full Text PDFAluminum, being the most abundant metal in the earth's crust, is widely distributed in the environment, and is routinely taken up by the human body through ingestion and inhalation. Aluminum is not considered an essential element and it can be toxic in high concentrations. Most of the body burden of aluminum is stored in the bones.
View Article and Find Full Text PDFTechnol Cancer Res Treat
August 2015
Purpose: To evaluate early perfusion changes in normal tissue following stereotactic radiosurgery (SRS).
Methods: Nineteen patients harboring twenty-two brain metastases treated with SRS were imaged with dynamic susceptibility magnetic resonance imaging (DSC MRI) at baseline, 1 week and 1 month post SRS. Relative cerebral blood volume and flow (rCBV and rCBF) ratios were evaluated outside of tumor within a combined region of interest (ROI) and separately within gray matter (GM) and white matter (WM) ROIs.
Ten female volunteers were recruited as part of the Ryerson and McMaster University Strontium (Sr) in Bone Research Study to have their bone Sr levels measured as they self-supplemented with Sr supplements of their choice. Of the ten volunteers, nine were suffering from osteopenia and/or osteoporosis. Non-invasive bone Sr measurements were performed using an in vivo x-ray fluorescence (IVXRF) I-125 based system.
View Article and Find Full Text PDFPlaster of Paris [poP, CaSO4·(1)/(2) H2O] is the standard phantom material used for the calibration of in vivo X-ray fluorescence (IVXRF)-based systems of bone metal quantification (i.e bone strontium and lead). Calibration of IVXRF systems of bone metal quantification employs the use of a coherent normalization procedure which requires the application of a coherent correction factor (CCF) to the data, calculated as the ratio of the relativistic form factors of the phantom material and bone mineral.
View Article and Find Full Text PDFStrontium ranelate is an approved pharmacotherapy for osteoporosis in Europe and Australia, but not in Canada or the United States. Strontium citrate, an alternative strontium salt, however, is available for purchase over-the-counter as a nutritional supplement. The effects of strontium citrate on bone are largely unknown.
View Article and Find Full Text PDFObjective: To find the best lead exposure assessment marker for children.
Methods: We recruited 11 children, calculated a cumulative blood lead index (CBLI) for the children, measured their concurrent BLL, assessed their development, and measured their bone lead level.
Results: Nine of 11 children had clinically significant neurodevelopment problems.
Background: There is a need for a diagnostic tool with the ability to measure cumulative exposure to manganese (Mn) in the workplace. Measuring bone Mn levels with in vivo neutron activation analysis (IVNAA) could serve as a biomarker of past exposure. Bone Mn levels of welders were measured and compared to the levels found in subjects without exposure to the element.
View Article and Find Full Text PDF