The surface composition and microstructure of an up to 5 µm thick multilayer on a knee implant were investigated. When the implant was explanted after approximately two years of clinical use due to failure from aseptic loosening, the topmost ZrN layer was found to be oxidized. Interestingly, only the non-articulating area was visibly oxidized (color change).
View Article and Find Full Text PDFThis study aims to evaluate and compare the properties of a biomedical clinically established zirconium nitride (ZrN) multilayer coating prepared using two different techniques: pulsed magnetron sputtering and cathodic arc deposition. The investigation focuses on the crystalline structure, grain size, in-vitro oxidation behaviour and tribological performance of these two coating techniques. Experimental findings demonstrate that the sputter deposition process resulted in a distinct crystalline structure and smaller grain size compared to the arc deposition process.
View Article and Find Full Text PDFBackground: Early total knee arthroplasty failures continue to surface in the literature. Cementation technique and implant design are two of the most important scenarios that can affect implant survivorship. Our objectives were to develop a more suitable preclinical test to evaluate the endurance of the implant-cement-bone interface under anterior shear and internal-external (I/E) torsional shear testing condition in a biomechanical sawbones.
View Article and Find Full Text PDFThe long term performance of total knee arthroplasty (TKA) with regards to the bearing materials is related to the aging behaviour of these materials. The use of highly crosslinked materials in hip arthroplasty improved the clinical outcome. Nevertheless, the outcome for these materials compared to conventional UHMWPE (ultra-high molecular weight polyethylene) remains controversial in TKA and alternative bearing materials may be advantageous to improve its outcome in the second and third decade.
View Article and Find Full Text PDFTotal knee arthroplasty is a well established treatment for degenerative joint disease, which is also performed as a treatment in younger and middle-aged patients who have a significant physical activity and high life expectancy. However, complications may occur due to biological responses to wear particles, as well as local and systemic hypersensitivity reactions triggered by metal ions and particles such as cobalt, chromium and molybdenum. The purpose of the study was to perform a highly demanding activities (HDA) knee wear simulation in order to compare the wear characteristics and metal ion release barrier function of a zirconium nitride (ZrN) coated knee implant, designed for patients with suspected metal ion hypersensitivity, against an uncoated knee implant made out of CoCrMo.
View Article and Find Full Text PDFBackside wear due to micromotion and poor conformity between the liner and its titanium alloy shell may contribute to the high rates of retroacetabular osteolysis and consequent aseptic loosening. The purpose of our study was to understand the wear process on the backside of polyethylene liners from two acetabular cup systems, whose locking mechanism is based on a press-fit cone in combination with a rough titanium conical inner surface on the fixation area. A direct comparison between in vitro wear simulator tests (equivalent to 3 years of use) and retrieved liners (average 13.
View Article and Find Full Text PDFIn vivo during the day, intervertebral discs are loaded mainly in compression causing fluid and height losses that are subsequently fully recovered overnight due to fluid inflow under smaller compression. However, in vitro, fluid flow through the endplates, in particular fluid imbibition, is hampered possibly by blood clots formed post mortem. Despite earlier in vitro studies, it remains yet unclear if and how fluid flow conditions in vitro could properly emulate those in vivo.
View Article and Find Full Text PDF