Acta Oncol
October 2024
Background And Purpose: Intensity Modulated Proton Therapy (IMPT) faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is an alternative to maintain target coverage, potentially improving organ at risk (OAR) sparing, reducing beam delivery time (BDT), and enhancing patient experience. We aim to perform a systematic plan comparison study between IMPT and energy layer (EL) and spot assignment algorithm - Proton Arc Therapy (ELSA-PAT) to assess its potential for lung cancer treatment.
View Article and Find Full Text PDFBackground: The reliable and efficient estimation of uncertainty in artificial intelligence (AI) models poses an ongoing challenge in many fields such as radiation therapy. AI models are intended to automate manual steps involved in the treatment planning workflow. We focus in this study on dose prediction models that predict an optimal dose trade-off for each new patient for a specific treatment modality.
View Article and Find Full Text PDFPurpose: Ethos proposes a template-based automatic dose planning (Etb) for online adaptive radiotherapy. This study evaluates the general performance of Etb for prostate cancer, as well as the ability to generate patient-optimal plans, by comparing it with another state-of-the-art automatic planning method, i.e.
View Article and Find Full Text PDFPurpose: Defining dosimetric rules to automatically detect patients requiring adaptive radiotherapy (ART) is not straightforward, and most centres perform ad-hoc ART with no specific protocol. This study aims to propose and analyse different steps to design a protocol for dosimetrically triggered ART of head and neck (H&N) cancer. As a proof-of-concept, the designed protocol was applied to patients treated in TomoTherapy units, using their available software for daily MVCT image and dose accumulation.
View Article and Find Full Text PDFBackground: In cancer care, determining the most beneficial treatment technique is a key decision affecting the patient's survival and quality of life. Patient selection for proton therapy (PT) over conventional radiotherapy (XT) currently entails comparing manually generated treatment plans, which requires time and expertise.
Purpose: We developed an automatic and fast tool, AI-PROTIPP (Artificial Intelligence Predictive Radiation Oncology Treatment Indication to Photons/Protons), that assesses quantitatively the benefits of each therapeutic option.
Purpose: Automated treatment planning strategies are being widely implemented in clinical routines to reduce inter-planner variability, speed up the optimization process, and improve plan quality. This study aims to evaluate the feasibility and quality of intensity-modulated proton therapy (IMPT) plans generated with four different knowledge-based planning (KBP) pipelines fully integrated into a commercial treatment planning system (TPS).
Materials/methods: A data set containing 60 oropharyngeal cancer patients was split into 11 folds, each containing 47 patients for training, five patients for validation, and five patients for testing.
Background And Purpose: This study aims to investigate how accurate our deep learning (DL) dose prediction models for intensity modulated radiotherapy (IMRT) and pencil beam scanning (PBS) treatments, when chained with normal tissue complication probability (NTCP) models, are at identifying esophageal cancer patients who are at high risk of toxicity and should be switched to proton therapy (PT).
Materials And Methods: Two U-Net were created, for photon (XT) and proton (PT) plans, respectively. To estimate the dose distribution for each patient, they were trained on a database of 40 uniformly planned patients using cross validation and a circulating test set.
To establish an open framework for developing plan optimization models for knowledge-based planning (KBP).Our framework includes radiotherapy treatment data (i.e.
View Article and Find Full Text PDFThe interest in machine learning (ML) has grown tremendously in recent years, partly due to the performance leap that occurred with new techniques of deep learning, convolutional neural networks for images, increased computational power, and wider availability of large datasets. Most fields of medicine follow that popular trend and, notably, radiation oncology is one of those that are at the forefront, with already a long tradition in using digital images and fully computerized workflows. ML models are driven by data, and in contrast with many statistical or physical models, they can be very large and complex, with countless generic parameters.
View Article and Find Full Text PDFPurpose: To integrate dose-averaged linear energy transfer (LET) into spot-scanning proton arc therapy (SPArc) optimization and to explore its feasibility and potential clinical benefits.
Methods: An open-source proton planning platform (OpenREGGUI) has been modified to incorporate LET into optimization for both SPArc and multi-beam intensity-modulated proton therapy (IMPT) treatment planning. SPArc and multi-beam IMPT plans with different beam configurations for a prostate patient were generated to investigate the feasibility of LET-based optimization using SPArc in terms of spatial LET distribution and plan delivery efficiency.
Artificial intelligence (AI) has recently become a very popular buzzword, as a consequence of disruptive technical advances and impressive experimental results, notably in the field of image analysis and processing. In medicine, specialties where images are central, like radiology, pathology or oncology, have seized the opportunity and considerable efforts in research and development have been deployed to transfer the potential of AI to clinical applications. With AI becoming a more mainstream tool for typical medical imaging analysis tasks, such as diagnosis, segmentation, or classification, the key for a safe and efficient use of clinical AI applications relies, in part, on informed practitioners.
View Article and Find Full Text PDFPurpose: To investigate the effect of data quality and quantity on the performance of deep learning (DL) models, for dose prediction of intensity-modulated radiotherapy (IMRT) of esophageal cancer.
Material And Methods: Two databases were used: a variable database (VarDB) with 56 clinical cases extracted retrospectively, including user-dependent variability in delineation and planning, different machines and beam configurations; and a homogenized database (HomDB), created to reduce this variability by re-contouring and re-planning all patients with a fixed class-solution protocol. Experiment 1 analysed the user-dependent variability, using 26 patients planned with the same machine and beam setup (E26-VarDB versus E26-HomDB).
Mach Learn Sci Technol
March 2021
Introduction: Pencil beam (PB) dose calculation is fast but inaccurate due to the approximations when dealing with inhomogeneities. Monte Carlo (MC) dose calculation is the most accurate method but it is time consuming. The aim of this study was to develop a deep learning model that can boost the accuracy of PB dose calculation to the level of MC dose by converting PB dose to MC dose for different tumor sites.
View Article and Find Full Text PDFPurpose: This work aims to study the generalizability of a pre-developed deep learning (DL) dose prediction model for volumetric modulated arc therapy (VMAT) for prostate cancer and to adapt the model, via transfer learning with minimal input data, to three different internal treatment planning styles and one external institution planning style.
Methods: We built the source model with planning data from 108 patients previously treated with VMAT for prostate cancer. For the transfer learning, we selected patient cases planned with three different styles, 14-29 cases per style, in the same institution and 20 cases treated in a different institution to adapt the source model to four target models in total.
Purpose: The purpose of this study was to address the dosimetric accuracy of synthetic computed tomography (sCT) images of patients with brain tumor generated using a modified generative adversarial network (GAN) method, for their use in magnetic resonance imaging (MRI)-only treatment planning for proton therapy.
Methods: Dose volume histogram (DVH) analysis was performed on CT and sCT images of patients with brain tumor for plans generated for intensity-modulated proton therapy (IMPT). All plans were robustly optimized using a commercially available treatment planning system (RayStation, from RaySearch Laboratories) and standard robust parameters reported in the literature.
Purpose: Robust optimization is a computational expensive process resulting in long plan computation times. This issue is especially critical for moving targets as these cases need a large number of uncertainty scenarios to robustly optimize their treatment plans. In this study, we propose a novel worst-case robust optimization algorithm, called dynamic minimax, that accelerates the conventional minimax optimization.
View Article and Find Full Text PDFIntroduction: Proton therapy is very sensitive to treatment uncertainties. These uncertainties can induce proton range variations and may lead to severe dose distortions. However, most commercial tools only offer a limited integration of these uncertainties during treatment planning.
View Article and Find Full Text PDFPurpose: The use of neural networks to directly predict three-dimensional dose distributions for automatic planning is becoming popular. However, the existing methods use only patient anatomy as input and assume consistent beam configuration for all patients in the training database. The purpose of this work was to develop a more general model that considers variable beam configurations in addition to patient anatomy to achieve more comprehensive automatic planning with a potentially easier clinical implementation, without the need to train specific models for different beam settings.
View Article and Find Full Text PDFPurpose: Monte Carlo (MC) dose calculation is generally superior to analytical dose calculation (ADC) used in commercial TPS to model the dose distribution especially for heterogeneous sites, such as lung and head/neck patients. The purpose of this study was to provide a validated, fast, and open-source MC code, MCsquare, to assess the impact of approximations in ADC on clinical pencil beam scanning (PBS) plans covering various sites.
Methods: First, MCsquare was validated using tissue-mimicking IROC lung phantom measurements as well as benchmarked with the general purpose Monte Carlo TOPAS for patient dose calculation.
Purpose: Analytical algorithms have a limited accuracy when modeling very heterogeneous tumor sites. This work addresses the performance of a hybrid dose optimizer that combines both Monte Carlo (MC) and pencil beam (PB) dose engines to get the best trade-off between speed and accuracy for proton therapy plans.
Methods: The hybrid algorithm calculates the optimal spot weights (w) by means of an iterative optimization process where the dose at each iteration is computed by using a precomputed dose influence matrix based on the conventional PB plus a correction term c obtained from a MC simulation.