A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) screening method was developed for the screening of 11 calcium channel blockers of the 1,4-dihydropyridine type in plasma samples for forensic and clinical cases. Plasma samples were extracted by automated solid-phase extraction. Analysis was performed using a reversed-phase C(18) column, gradient elution and a triple-quadrupole mass spectrometer with TurboIonSpray source in positive mode and multiple reaction monitoring.
View Article and Find Full Text PDF