Despite the high prevalence of low birth weight infants in sub-Saharan Africa and the associated poor outcomes, weight change during the newborn period has not been well characterized for this population. We prospectively assessed growth over the first 30 days among 120 infants born < 2000 g (g) in Guinea-Bissau and Uganda, and compared it to a similar cohort of 420 infants born ≥ 2000 g. Among those born < 2000 g, mean birth weight was 1747 ± 164 g, and initial weight loss was 8.
View Article and Find Full Text PDFRes Pract Thromb Haemost
February 2024
Background: Tranexamic acid (TXA) is an antifibrinolytic agent that reduces bleeding in a multitude of clinical settings from postpartum hemorrhage to trauma. TXA may have clinical effects unrelated to bleeding; plasminogen, the target of TXA, alters immune responses, and TXA appears to decrease the risk of infection in patients undergoing cardiac surgery, as well as joint arthroplasty.
Objectives: To address whether TXA alters rates of infection and inflammatory outcomes in patients with hematologic malignancies.
Background: Randomized controlled trials in Guinea-Bissau and Uganda have revealed that the intensive promotion of exclusive breastfeeding (EBF) impairs growth in early infancy. When newborn growth is impaired, small amounts of formula may be combined with breastfeeding to promote growth.
Methods: To determine if breastfeeding combined with once-daily formula supplementation improves growth among at-risk newborns, we conducted a pilot randomized controlled trial in Bissau, Guinea-Bissau and Kampala, Uganda.
Lancet Glob Health
December 2023
Background: Pulse oximeters are not routinely available in outpatient clinics in low- and middle-income countries. We derived clinical scores to identify hypoxemic child pneumonia.
Methods: This was a retrospective pooled analysis of two outpatient datasets of 3-35 month olds with World Health Organization (WHO)-defined pneumonia in Bangladesh and Malawi.
Growth impairment is common in low- and middle-income countries (LMIC) and may begin during early infancy, increasing morbidity and mortality. To ensure healthy infant growth, healthcare providers in high-income countries (HIC) track newborn weight change using tools developed and validated in HIC. To understand the utility of these tools for LMIC, we conducted a secondary analysis to compare weight trajectories in the first 5 days of life among newborns born in our LMIC cohort to an existing HIC newborn weight tool designed to track early weight change.
View Article and Find Full Text PDFBackground: Despite its associated benefits which include better long-term pulmonary and neurodevelopmental outcome, the use of caffeine for apnoea of prematurity (AoP) has been limited in low- and middle-income countries (LMIC).
Aim: To better understand current caffeine use, the barriers and facilitators to its use and perceptions and practices in LMIC which have a disproportionately high burden of prematurity.
Methods: An anonymous online global survey was conducted, targeting healthcare providers working and training in paediatrics and/or neonatology in LMIC.
Background: Apnoea of prematurity (AOP) is a common condition among preterm infants. Methylxanthines, such as caffeine and aminophylline/theophylline, can help prevent and treat AOP. Due to its physiological benefits and fewer side effects, caffeine citrate is recommended for the prevention and treatment of AOP.
View Article and Find Full Text PDFJ Empir Res Hum Res Ethics
October 2023
Background: Hypoxaemic pneumonia mortality risk in low-income and middle-income countries is high in children who have been hospitalised, but unknown among outpatient children. We sought to establish the outpatient burden, mortality risk, and prognostic accuracy of death from hypoxaemia in children with suspected pneumonia in Bangladesh.
Methods: We conducted a prospective community-based cohort study encompassing three upazila (subdistrict) health complex catchment areas in Sylhet, Bangladesh.
Accurate clinical sensors and devices are essential to support optimal medical decision-making, and accuracy can be demonstrated through the conduct of clinical validation studies using validated reference sensors and/or devices for comparison. Typically unmeasurable, the true reference value can be substituted with an accepted physiological measurement with an associated uncertainty. We describe a basic model of measurement uncertainty that specifies the factors that may degrade the accuracy of an observed measurement value from a sensor, and we detail validation study design strategies that may be used to quantify and minimize these uncertainties.
View Article and Find Full Text PDFBackground: This study assessed safety and immunogenicity of Serum Institute of India Pvt Ltd (SIIPL)'s tetanus toxoid (TT), diphtheria toxoid (DT), and acellular pertussis booster vaccine (Tdap).
Research Design And Methods: In this Phase II/III, multicenter, randomized, active-controlled, open-label study, 1500 healthy individuals, aged 4-65 years, were randomized to receive a single dose of SIIPL Tdap or comparator Tdap vaccine (Boostrix®; GlaxoSmithKlines, India). Adverse events (AEs) during initial 30 minutes, 7-day, 30-day post-vaccination were assessed.
Point-of-care ultrasound has the potential to help inform assessment, diagnosis, and management of illness in low- and middle-income countries (LMIC). To better understand current ultrasound use, barriers and facilitators to use, and perceptions and practices in LMIC, we conducted an anonymous online global survey targeting healthcare providers training and using ultrasound in LMIC. A total of 241 respondents representing 62 countries participated and most were physicians working in publicly-funded urban tertiary hospitals in LMIC.
View Article and Find Full Text PDFIn low- and middle-income countries (LMIC), growth impairment is common; however, the trajectory of growth over the course of the first month has not been well characterised. To describe newborn growth trajectory and predictors of growth impairment, we assessed growth frequently over the first 30 days among infants born ≥2000 g in Guinea-Bissau, Nepal, Pakistan and Uganda. In this cohort of 741 infants, the mean birth weight was 3036 ± 424 g.
View Article and Find Full Text PDFClinically feasible multiparameter continuous physiological monitoring technologies are needed for use in resource-constrained African healthcare facilities to allow for early detection of critical events and timely intervention for major morbidities in high-risk neonates. We conducted a prospective clinical feasibility study of a novel multiparameter continuous physiological monitoring technology in neonates at Pumwani Maternity Hospital in Nairobi, Kenya. To assess feasibility, we compared the performance of Sibel's Advanced Neonatal Epidermal (ANNE) technology to reference technologies, including Masimo's Rad-97 pulse CO-oximeter with capnography technology for heart rate (HR), respiratory rate (RR), and oxygen saturation (SpO) measurements and Spengler's Tempo Easy non-contact infrared thermometer for temperature measurements.
View Article and Find Full Text PDFBackground: Neonatal multiparameter continuous physiological monitoring (MCPM) technologies assist with early detection of preventable and treatable causes of neonatal mortality. Evaluating accuracy of novel MCPM technologies is critical for their appropriate use and adoption.
Methods: We prospectively compared the accuracy of Sibel's Advanced Neonatal Epidermal (ANNE) technology with Masimo's Rad-97 pulse CO-oximeter with capnography and Spengler's Tempo Easy reference technologies during four evaluation rounds.
Accurate measurement of respiratory rate (RR) in neonates is challenging due to high neonatal RR variability (RRV). There is growing evidence that RRV measurement could inform and guide neonatal care. We sought to quantify neonatal RRV during a clinical study in which we compared multiparameter continuous physiological monitoring (MCPM) devices.
View Article and Find Full Text PDFAmoxicillin is recommended as first-line antibiotic treatment for community-acquired pneumonia, the leading infectious cause of mortality in children aged less than 5 years. We conducted a double-blind, randomized controlled non-inferiority trial comparing 3- to 5-day amoxicillin treatment for non-severe chest-indrawing pneumonia in HIV-negative children aged 2 to 59 months in Malawi. In a secondary analysis, we assessed the frequency of serious adverse events (SAEs) during the trial to evaluate the safety of treatment with amoxicillin.
View Article and Find Full Text PDFMultiparameter continuous physiological monitoring (MCPM) technologies are critical in the clinical management of high-risk neonates; yet, these technologies are frequently unavailable in many African healthcare facilities. We conducted a prospective clinical feasibility study of EarlySense's novel under-mattress MCPM technology in neonates at Pumwani Maternity Hospital in Nairobi, Kenya. To assess feasibility, we compared the performance of EarlySense's technology to Masimo's Rad-97 pulse CO-oximeter with capnography technology for heart rate (HR) and respiratory rate (RR) measurements using up-time, clinical event detection performance, and accuracy.
View Article and Find Full Text PDFChildhood undernutrition is a major health burden worldwide that increases childhood morbidity and mortality and causes impairment in infant growth and developmental delays that can persist into adulthood. The first weeks and months after birth are critical to the establishment of healthy growth and development during childhood. The World Health Organization recommends immediate and exclusive breastfeeding (EBF).
View Article and Find Full Text PDF