We investigated the morphology and intracellular motility of mammary epithelial cell (MCF10DCIS.com) spheroids cultured in 3D artificial extracellular matrix under perfluorooctanoic acid (PFOA) exposure. Dynamic optical coherence tomography (OCT) was employed for real-time, non-invasive imaging of these spheroids longitudinally over 12 days under PFOA exposures up to 500 µM.
View Article and Find Full Text PDFSignificance: Optical coherence tomography has great utility for capturing dynamic processes, but such applications are particularly data-intensive. Samples such as biological tissues exhibit temporal features at varying time scales, which makes data reduction challenging.
Aim: We propose a method for capturing short- and long-term correlations of a sample in a compressed way using non-uniform temporal sampling to reduce scan time and memory overhead.
Significance: Assessing the nanostructure of polymer solutions and biofluids is broadly useful for understanding drug delivery and disease progression and for monitoring therapy.
Aim: Our objective is to quantify bronchial mucus solids concentration (wt. %) during hypertonic saline (HTS) treatment via nanostructurally constrained diffusion of gold nanorods (GNRs) monitored by polarization-sensitive optical coherence tomography (PS-OCT).
An ultrasound-based system capable of both imaging thrombi against a dark field and performing quantitative elastometry could allow for fast and cost-effective thrombosis diagnosis, staging, and treatment monitoring. This study investigates a contrast-enhanced approach for measuring the Young's moduli of thrombus-mimicking phantoms.Magnetomotive ultrasound (MMUS) has shown promise for lending specific contrast to thrombi by applying a temporally modulated force to magnetic nanoparticle (MNP) contrast agents and measuring resulting tissue displacements.
View Article and Find Full Text PDFPlasmonic nanoparticles that can be manipulated with magnetic fields are of interest for advanced optical applications, diagnostics, imaging, and therapy. Alignment of gold nanorods yields strong polarization-dependent extinction, and use of magnetic fields is appealing because they act through space and can be quickly switched. In this work, cationic polyethyleneimine-functionalized superparamagnetic Fe O nanoparticles (NPs) are deposited on the surface of anionic gold nanorods coated with bovine serum albumin.
View Article and Find Full Text PDFObjectives/hypothesis: To establish the utility of anatomic optical coherence tomography (aOCT) in evaluating internal nasal valve (INV).
Study Design: Anatomic specimen imaging study.
Methods: Fresh-harvested human specimen heads were evaluated using both computed tomography (CT) imaging as well as using aOCT.
Endoscopic optical coherence tomography of large airways poses unique challenges. A hybrid lens is described that consists of a section of coreless fiber and graded index fiber (GIF), followed by a ball lens section. This design produces low numerical aperture beams better suited for large airway imaging.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2021
Magnetomotive Ultrasound (MMUS) is an emerging imaging modality, in which magnetic nanoparticles (MNPs) are used as contrast agents. MNPs are driven by a time-varying magnetic force, and the resulting movement of the surrounding tissue is detected with a signal processing algorithm. However, there is currently no analytical model to quantitatively predict this magnetically-induced displacement.
View Article and Find Full Text PDFJ Mammary Gland Biol Neoplasia
June 2021
Basal-like breast cancers (BBC) exhibit subtype-specific phenotypic and transcriptional responses to stroma, but little research has addressed how stromal-epithelial interactions evolve during early BBC carcinogenesis. It is also unclear how common genetic defects, such as p53 mutations, modify these stromal-epithelial interactions. To address these knowledge gaps, we leveraged the MCF10 progression series of breast cell lines (MCF10A, MCF10AT1, and MCF10DCIS) to develop a longitudinal, tissue-contextualized model of p53-deficient, pre-malignant breast.
View Article and Find Full Text PDFQuantitative methods for assessing the severity of inhalation (burn) injury are needed to aid in treatment decisions. We hypothesize that it is possible to assess the severity of injuries on the basis of differences in the compliance of the airway wall. Here, we demonstrate the use of a custom-built, endoscopic, anatomic optical coherence elastography (aOCE) system to measure airway wall compliance.
View Article and Find Full Text PDF3D paper-based cultures (PBCs) are easy-to-use and provide a biologically representative microenvironment. By stacking a sheet of cell-laden paper below sheets containing cell-free hydrogel, we form an assay capable of segmenting cells by the distance they invaded from the original cell-seeded layer. These invasion assays are limited to end-point analyses with fluorescence-based readouts due to the highly scattering nature of the paper scaffolds.
View Article and Find Full Text PDFBackground: An understanding of how the mammary gland responds to toxicant and drug exposures can shed light on mechanisms of breast cancer initiation/progression and therapeutic effectiveness, respectively. In this study, we employed noninvasive, label-free and high-throughput optical coherence tomography speckle fluctuation spectroscopy (OCT-SFS) to track exposure-response relationships in three-dimensional (3D) mammary epithelial organoid models.
Methods: OCT-SFS is sensitive to relatively high speed (~0.
We describe an elastographic method to circumferentially-resolve airway wall compliance using endoscopic, anatomic optical coherence tomography (aOCT) combined with an intraluminal pressure catheter. The method was first demonstrated on notched silicone phantoms of known elastic modulus under respiratory ventilation, where localized compliance measurements were validated against those predicted by finite element modeling. Then, ex vivo porcine tracheas were scanned, and the pattern of compliance was found to be consistent with histological identification of the locations of (stiff) cartilage and (soft) muscle.
View Article and Find Full Text PDFMagnetomotive ultrasound (MMUS) contrasts superparamagnetic iron-oxide nanoparticles (SPIOs) that undergo submicrometer-scale displacements in response to a magnetic gradient force applied to an imaging sample. Typically, MMUS signals are defined in a way that is proportional to the medium displacement, rendering an indirect measure of the density distribution of SPIOs embedded within. Displacement-based MMUS, however, suffers from 'halo effects' that extend into regions without SPIOs due to their inherent mechanical coupling with the medium.
View Article and Find Full Text PDFIt is hypothesized that the local, viscoelastic (time-dependent) properties of the airway are important to accurately model and ultimately predict dynamic airway collapse in airway obstruction. Toward this end, we present a portable, endoscopic, swept-source anatomical optical coherence tomography (aOCT) system combined with a pressure catheter to capture local airway dynamics in vivo during respiration. aOCT scans were performed in the airways of a mechanically ventilated pig under paralysis with dynamic and static ventilation protocols.
View Article and Find Full Text PDFIdentification and treatment of obstructive airway disorders (OADs) are greatly aided by imaging of the geometry of the airway lumen. Anatomical optical coherence tomography (aOCT) is a promising high-speed and minimally invasive endoscopic imaging modality for providing micrometer-resolution scans of the upper airway. Resistance to airflow in OADs is directly caused by the reduction in luminal cross-sectional area (CSA).
View Article and Find Full Text PDFIn magnetomotive ultrasound (MMUS) imaging, an oscillating external magnetic field displaces tissue loaded with super-paramagnetic iron oxide (SPIO) particles. The induced motion is on the nanometer scale, which makes its detection and its isolation from background motion challenging. Previously, a frequency and phase locking (FPL) algorithm was used to suppress background motion by subtracting magnetic field off ( -off) from on ( -on) data.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2018
Direct ultrasonic imaging of arterial and venous thrombi could aid in diagnosis and treatment planning by providing rapid and cost-effective measurements of thrombus volume and elastic modulus. Toward this end, it was demonstrated that open-air magnetomotive ultrasound (MMUS) provides specific contrast to superparamagnetic iron oxide-labeled model thrombi embedded in gelatin-based blood vessel-mimicking flow phantoms. MMUS was performed on model thrombi in the presence of pulsatile flow that mimics cardiac-induced motion found in real vasculature.
View Article and Find Full Text PDFPurpose: To evaluate the presence and length of microcracks in resin-based materials finished with different techniques, using optical coherence tomography (OCT).
Methods: Standardized Class V preparations (3x2x2mm) were made in the facial and lingual surfaces of 20 recently-extracted human third molars. 20 preparations were restored with a resin-based composite material (RBC; Filtek Supreme Ultra) and the other 20 with a resin-modified glass-ionomer material (RMGI; Ketac Nano).
In situ measurements of diffusive particle transport provide insight into tissue architecture, drug delivery, and cellular function. Analogous to diffusion-tensor magnetic resonance imaging (DT-MRI), where the anisotropic diffusion of water molecules is mapped on the millimeter scale to elucidate the fibrous structure of tissue, here we propose diffusion-tensor optical coherence tomography (DT-OCT) for measuring directional diffusivity and flow of optically scattering particles within tissue. Because DT-OCT is sensitive to the sub-resolution motion of Brownian particles as they are constrained by tissue macromolecules, it has the potential to quantify nanoporous anisotropic tissue structure at micrometer resolution as relevant to extracellular matrices, neurons, and capillaries.
View Article and Find Full Text PDFThe ability to assess toxicant exposures of 3D in vitro mammary models that recapitulate the tissue microenvironment can aid in our understanding of environmental exposure risk over time. Longitudinal studies of 3D model systems, however, are cumbersome and suffer from a lack of high-throughput toxicological assays. In this study, we establish a noninvasive and label-free optical coherence tomography (OCT)-based imaging platform for tracking exposure-response relationships in 3D human mammary epithelial organoid models.
View Article and Find Full Text PDFProc SPIE Int Soc Opt Eng
February 2017
We describe a novel, multi-modal imaging protocol for validating quantitative dynamic airway imaging performed using anatomical Optical Coherence Tomography (aOCT). The aOCT system consists of a catheter-based aOCT probe that is deployed via a bronchoscope, while a programmable ventilator is used to control airway pressure. This setup is employed on the bed of a Siemens Biograph CT system capable of performing respiratory-gated acquisitions.
View Article and Find Full Text PDFQuantification of airway compliance can aid in the diagnosis and treatment of obstructive airway disorders by detecting regions vulnerable to collapse. Here we evaluate the ability of a swept-source anatomic optical coherence tomography (SSaOCT) system to quantify airway cross-sectional compliance (CC) by measuring changes in the luminal cross-sectional area (CSA) under physiologically relevant pressures of 10-40 cmHO. The accuracy and precision of CC measurements are determined using simulations of non-uniform rotation distortion (NURD) endemic to endoscopic scanning, and experiments performed in a simplified tube phantom and porcine tracheas.
View Article and Find Full Text PDFThe three most important metrics in optical coherence tomography (OCT) are resolution, speed, and sensitivity. Because there is a complex interplay between these metrics, no previous work has obtained the best performance in all three metrics simultaneously. We demonstrate that a high-power supercontinuum source, in combination with parallel spectral-domain OCT, achieves an unparalleled combination of resolution, speed, and sensitivity.
View Article and Find Full Text PDFMucus hydration (wt%) has become an increasingly useful metric in real-time assessment of respiratory health in diseases like cystic fibrosis and COPD, with higher wt% indicative of diseased states. However, available rheological techniques are lacking. Gold nanorods (GNRs) are attractive biological probes whose diffusion through tissue is sensitive to the correlation length of comprising biopolymers.
View Article and Find Full Text PDF