Left subclavian artery (LSA) revascularization is recommended during elective thoracic endovascular aortic aneurysm repair (TEVAR) when coverage is required for adequate proximal seal. Reported method for LSA revascularization includes open bypass, covered stent placement using chimney technique, and in situ laser fenestration. We reported a novel technique using percutaneous Outback reentry device for LSA revascularization in a 68-year-old male patient who underwent TEVAR for a 9-cm thoracic aortic aneurysm.
View Article and Find Full Text PDFObjectives: Extracranial carotid artery true aneurysm is extremely uncommon, and definite treatment has traditionally involved open surgical repair. Although successful management of the internal carotid artery aneurysms using endovascular stenting and embolization has recently been reported, only a limited number of cases have been reported.
Methods: We present a case of symptomatic carotid true aneurysm repaired with covered stent and coil embolization of the external carotid artery.
Lower extremity deep venous thrombosis (DVT) is uncommon in the pediatric population, but it can be associated with severe symptoms and potential long-term morbidity secondary to post-thrombotic syndrome. Inferior vena cava (IVC) atresia can predispose a patient to the development of extremity DVT. There is no clear consensus on optimal management of extensive extremity DVT in pediatric patients, especially in patients with IVC anomalies.
View Article and Find Full Text PDFObjectives: This study was conducted to investigate the progression of lower extremity ischemia following kidney transplantation to iliac artery in patients with peripheral arterial disease.
Methods: A retrospective chart review of all renal transplant patients completed at a university teaching medical center from January 2006 to December of 2011 was performed. A total of 219 patients underwent successful kidney transplantation to the common, external, or internal iliac artery.
Until recently, the Cook Zenith aortic endograft (Cook Medical Inc, Bloomington, Ind) was the only device used for physician-modified fenestration because its constraining wire allowed physicians to reconstrain the device after modifications. Although the Cook Zenith fenestrated endograft has been approved by the Food and Drug Administration, it is currently not available in the majority of the hospitals and is not applicable to the patients who need urgent or emergent aneurysm repair. With the redesign of the Gore C3 delivery system, the Gore Excluder aortic stent graft (W.
View Article and Find Full Text PDFPopliteal vein aneurysms (PVAs) can have serious consequences, including pulmonary embolism and death. We report a case of PVA in a previously healthy 58-year-old female with a history of pain in her right popliteal fossa for the past 3 years. Patient had no history of trauma or claudication of the right leg.
View Article and Find Full Text PDF