To redevelop a neutralizing antibody (NAb) assay to be much more drug tolerant, have a large dynamic range and have high inhibition when using high levels of positive control (PC). Early assay data suggested that typical biotin labeling of the capture reagent (Drug 1, produced in a human cell line) was blocking it from binding with the PC or the detection target, and that the detection target was out competing the PC. Methodical biotin labeling experiments were performed at several challenge ratios and an Fc linker was added to the detection target.
View Article and Find Full Text PDFThe measurement of antidrug antibodies (ADA) in nonclinical studies provides limited value because the formation and incidence of nonclinical ADA does not translate to clinical experience. The formation and presence of ADA in nonclinical species can, however, correlate to reduced drug exposure and safety observations including vasculitis and immune complex disease. Generic ADA methods for humanized monoclonal antibody biotherapeutics mitigate the need to develop bespoke ADA methods during nonclinical drug development.
View Article and Find Full Text PDF