Rapid and accurate quantification of metabolites in different bodily fluids is crucial for a precise health evaluation. However, conventional metabolite sensing methods, confined to centralized laboratory settings, suffer from time-consuming processes, complex procedures, and costly instrumentation. Introducing the MXene/nitrogen-doped electrochemically exfoliated graphene (MXene@N-EEG) nanocomposite as a novel biosensing platform in this work addresses the challenges associated with conventional methods, leveraging the concept of molecularly imprinted polymers (MIP) enables the highly sensitive, specific, and reliable detection of metabolites.
View Article and Find Full Text PDFMicromachines (Basel)
November 2023
The separation of rare cells from complex biofluids has attracted attention in biological research and clinical applications, especially for cancer detection and treatment. In particular, various technologies and methods have been developed for the isolation of circulating tumor cells (CTCs) in the blood. Among them, the induced-charge electrokinetic (ICEK) flow method has shown its high efficacy for cell manipulation where micro-vortices (MVs), generated as a result of induced charges on a polarizable surface, can effectively manipulate particles and cells in complex fluids.
View Article and Find Full Text PDFCentrifugal microfluidics holds the potential to revolutionize point-of-care (POC) testing by simplifying laboratory tests through automating fluid and cell manipulation within microfluidic channels. This technology can facilitate blood testing, the most frequent clinical test, at the POC. However, an integrated centrifugal microfluidic device for complete blood counting (CBC) has not yet been fully realized.
View Article and Find Full Text PDFJ Extracell Vesicles
September 2023
Small extracellular vesicles (EVs) have emerged as a focal point of EV research due to their significant role in a wide range of physiological and pathological processes within living systems. However, uncertainties about the nature of these vesicles have added considerable complexity to the already difficult task of developing EV-based diagnostics and therapeutics. Whereas small EVs have been shown to be negatively charged, their surface charge has not yet been properly quantified.
View Article and Find Full Text PDFElevated glial fibrillary acidic protein (GFAP) in the blood serum is one of the promising bodily fluid markers for the diagnosis of central nervous system (CNS) injuries, including traumatic brain injury (TBI), stroke, and spinal cord injury (SCI). However, accurate and point-of-care (POC) quantification of GFAP in clinical blood samples has been challenging and yet to be clinically validated against gold-standard assays and outcome practices. This work engineered and characterized a novel nanoporous carbon screen-printed electrode with significantly increased surface area and conductivity, as well as preserved stability and anti-fouling properties.
View Article and Find Full Text PDFThe widespread accessibility of commercial/clinically-viable electrochemical diagnostic systems for rapid quantification of viral proteins demands translational/preclinical investigations. Here, Covid-Sense (CoVSense) antigen testing platform; an all-in-one electrochemical nano-immunosensor for sample-to-result, self-validated, and accurate quantification of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid (N)-proteins in clinical examinations is developed. The platform's sensing strips benefit from a highly-sensitive, nanostructured surface, created through the incorporation of carboxyl-functionalized graphene nanosheets, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) conductive polymers, enhancing the overall conductivity of the system.
View Article and Find Full Text PDFStress affects cognition, behavior, and physiology, leading to lasting physical and mental illness. The ability to detect and measure stress, however, is poor. Increased circulating cortisol during stress is mirrored by cortisol release from sweat glands, providing an opportunity to use it as an external biomarker for monitoring internal emotional state.
View Article and Find Full Text PDFCurrent laboratory diagnostic approaches for virus detection give reliable results, but they require a lengthy procedure, trained personnel, and expensive equipment and reagents; hence, they are not a suitable choice for home monitoring purposes. This paper addresses this challenge by developing a portable impedimetric biosensing system for the identification of COVID-19 patients. This sensing system has two main parts: a throwaway two-working electrode (2-WE) strip and a novel read-out circuit, specifically designed for simultaneous signal acquisition from both working electrodes.
View Article and Find Full Text PDFThe development of robust biosensing strategies that can be easily implemented in everyday life remains a challenge for the future of modern biosensor research. While several reagentless approaches have attempted to address this challenge, they often achieve user-friendliness through sacrificing sensitivity or universality. While acceptable for certain applications, these trade-offs hinder the widespread adoption of reagentless biosensing technologies.
View Article and Find Full Text PDFElectrochemical immuno-biosensors are one of the most promising approaches for accurate, rapid, and quantitative detection of protein biomarkers. The two-working electrode strip is employed for creating a self-supporting system, as a tool for self-validating the acquired results for added reliability. However, the realization of multiplex electrochemical point-of-care testing (ME-POCT) requires advancement in portable, rapid reading, easy-to-use, and low-cost multichannel potentiostat readers.
View Article and Find Full Text PDFFuture point-of-care (PoC) and wearable electrochemical biosensors explore new technology solutions to eliminate the need for multistep electrode modification and functionalization, overcome the limited reproducibility, and automate the sensing steps. In this work, a new screen-printed immuno-biosensor strip is engineered and characterized using a hybrid graphene nanosheet intermixed with the conductive poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) polymers, all embedded within the base carbon matrix (GiPEC) of the screen-printing ink. This intermixed nanocomposite ink is chemically designed for self-containing the "carboxyl" functional groups as the most specific chemical moiety for protein immobilization on the electrodes.
View Article and Find Full Text PDFThe evaporation of particle-laden sessile droplets is associated with capillary-driven outward flow and leaves nonuniform coffee-ring-like particle patterns due to far-from-equilibrium effects. Traditionally, the surface energies of the drop and solid phases are tuned, or external forces are applied to suppress the coffee-ring; however, achieving a uniform and repeatable particle deposition is extremely challenging. Here, we report a simple, scalable, and noninvasive technique that yields uniform and exceptionally ordered particle deposits on a microscale surface area by placing the droplet on a near neutral-wet shadow mold attached to a hydrophilic substrate.
View Article and Find Full Text PDFThe integration of electrochemical biosensors into fluid handling units such as paper-based, centrifugal, and capillary microfluidic devices has been explored with the purpose of developing point-of-care platforms for quantitative detection of bodily fluid markers. However, the present fluidic device designs largely lack the capacity of full assay automation, needing manual loading of one or multiple reagents or requiring external devices for liquid manipulation. Such fluidic handing platforms also require universality for detecting various biomarkers.
View Article and Find Full Text PDFThere is a growing interest to understand if and how the gut microbiome is causally linked to the pathogenesis and/or progression of diseases. While in vitro cell line models are commonly used for studying specific aspects of the host-microbe interaction, gnotobiotic murine models are considered the preferred platform for studying causality in microbiome research. Nevertheless, findings from animal studies provide limited opportunity for delineating various areas of interest to the human gut microbiome research.
View Article and Find Full Text PDFThe widespread and long-lasting effect of the COVID-19 pandemic has called attention to the significance of technological advances in the rapid diagnosis of SARS-CoV-2 virus. This study reports the use of a highly stable buffer-based zinc oxide/reduced graphene oxide (bbZnO/rGO) nanocomposite coated on carbon screen-printed electrodes for electrochemical immuno-biosensing of SARS-CoV-2 nuelocapsid (N-) protein antigens in spiked and clinical samples. The incorporation of a salt-based (ionic) matrix for uniform dispersion of the nanomixture eliminates multistep nanomaterial synthesis on the surface of the electrode and enables a stable single-step sensor nanocoating.
View Article and Find Full Text PDFMultiplex electrochemical biosensors have been used for eliminating the matrix effect in complex bodily fluids or enabling the detection of two or more bioanalytes, overall resulting in more sensitive assays and accurate diagnostics. Many electrochemical biosensors lack reliable and low-cost multiplexing to meet the requirements of point-of-care detection due to either limited functional biosensors for multi-electrode detection or incompatible readout systems. We developed a new dual electrochemical biosensing unit accompanied by a customized potentiostat to address the unmet need for point-of-care multi-electrode electrochemical biosensing.
View Article and Find Full Text PDFThe realization of true point-of-care (PoC) systems profoundly relies on integrating the bioanalytical assays into "on-chip" fluid handing platforms, with autonomous performance, reproducible functionality, and capacity in scalable production. Specifically for electrochemical immuno-biosensing, the complexity of the procedure used for ultrasensitive protein detection using screen-printed biosensors necessitates a lab-centralized practice, hindering the path towards near-patient use. This work develops a self-powered microfluidic chip that automates the entire assay of electrochemical immuno-biosensing, enabling controlled and sequential delivery of the biofluid sample and the sensing reagents to the surface of the embedded electrochemical biosensor.
View Article and Find Full Text PDFAcoustophoretic microfluidic devices have been developed for accurate, label-free, contactless, and non-invasive manipulation of bioparticles in different biofluids. However, their widespread application is limited due to the need for the use of high quality microchannels made of materials with high specific acoustic impedances relative to the fluid (e.g.
View Article and Find Full Text PDFExosomes are cell-derived structures packaged with lipids, proteins, and nucleic acids. They exist in diverse bodily fluids and are involved in physiological and pathological processes. Although their potential for clinical application as diagnostic and therapeutic tools has been revealed, a huge bottleneck impeding the development of applications in the rapidly burgeoning field of exosome research is an inability to efficiently isolate pure exosomes from other unwanted components present in bodily fluids.
View Article and Find Full Text PDFPhysiologically relevant intracranial aneurysm (IA) models are crucially required to facilitate testing treatment options for IA. Herein, we report the development of a new in vitro tissue-engineered platform, which recapitulates the microenvironment, structure, and cellular complexity of native human IA. A new modified liquid-assisted injection molding technique was developed to fabricate a three-dimensional hollow IA model with clinically relevant IA dimensions within a mechanically tuned Gelatin Methacryloyl (GelMA) hydrogel.
View Article and Find Full Text PDFThis work develops a robust classifier for a COVID-19 pre-screening model from crowdsourced cough sound data. The crowdsourced cough recordings contain a variable number of coughs, with some input sound files more informative than the others. Accurate detection of COVID-19 from the sound datasets requires overcoming two main challenges (i) the variable number of coughs in each recording and (ii) the low number of COVID-positive cases compared to healthy coughs in the data.
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
July 2021
Investigating axonal myelination by Schwann cells (SCs) is crucial for understanding mechanisms underlying demyelination and remyelination, which may help gain insights into incurable disorders like neurodegenerative diseases. In this study, a gelatin-based hydrogel, gelatin methacryloyl (GelMA), was optimized to achieve the biocompatibility, porosity, mechanical stability, and degradability needed to provide high cell viability for dorsal root ganglia (DRG) neurons and SCs, and to enable their long-term coculture needed for myelination studies. The results of cell viability, neurite elongation, SC function and maturation, SC-axon interaction, and myelination were compared with two other commonly used substrates, namely collagen and Poly-d Lysine (PDL).
View Article and Find Full Text PDFDroplets produced within microfluidics have not only attracted the attention of researchers to develop complex biological, industrial and clinical testing systems but also played a role as a bit of data. The flow of droplets within a network of microfluidic channels by stimulation of their movements, trajectories, and interaction timing, can provide an opportunity for preparation of complex and logical microfluidic circuits. Such mechanical-based circuits open up avenues to mimic the logic of electrical circuits within microfluidics.
View Article and Find Full Text PDFMicrofluidic chemical gradient generators enable precise spatiotemporal control of chemotactic signals to study cellular behavior with high resolution and reliability. However, time and cost consuming preparation steps for cell adhesion in microchannels as well as requirement of pumping facilities usually complicate the application of the microfluidic assays. Here, we introduce a simple strategy for preparation of a reusable and stand-alone microfluidic gradient generator to study cellular behavior.
View Article and Find Full Text PDFThe complexity and heterogeneity of the three-dimensional (3D) tumor microenvironment have brought challenges to tumor studies and cancer treatment. The complex functions and interactions of cells involved in tumor microenvironment have led to various multidrug resistance (MDR) and raised challenges for cancer treatment. Traditional tumor models are limited in their ability to simulate the resistance mechanisms and not conducive to the discovery of multidrug resistance and delivery processes.
View Article and Find Full Text PDF