Publications by authors named "Amir Pourmorteza"

Photon-counting computed tomography (PCCT) marks a significant advancement over conventional energy-integrating detector (EID) CT systems. This review highlights PCCT's superior spatial and contrast resolution, reduced radiation dose, and multi-energy imaging capabilities, which address key challenges in radiotherapy, such as accurate tumor delineation, precise dose calculation, and treatment response monitoring. PCCT's improved anatomical clarity enhances tumor targeting while minimizing damage to surrounding healthy tissues.

View Article and Find Full Text PDF

Background Photon-counting CT (PCCT) represents a recent advancement in CT, offering improved spatial resolution and spectral separability. By using multiple adjustable energy bins, PCCT enables K-edge imaging, allowing mixed contrast agent distinction. Deep-silicon is a new type of photon-counting detector with different characteristics compared with cadmium photon-counting detectors.

View Article and Find Full Text PDF

Contained within this volume are the scholarly contributions presented in both oral and poster formats at Fully3D 2023: The 17th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine. This conference convened from July 16-21, 2023, at Stony Brook University in New York. For ease of reference, all papers are organized alphabetically according to the last names of the primary authors.

View Article and Find Full Text PDF

Recent advancements in diagnostic CT detector technology have made it possible to resolve anatomical features smaller than 20 LP/cm, referred to as ultra-high-resolution (UHR) CT. Subtle biological motions that did not affect standard-resolution (SR) CT may not be neglected in UHR. This study aimed to quantify the cardiac-induced motion of the pancreas and simulate its impact on the image quality of UHR-CT.

View Article and Find Full Text PDF

CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal.

View Article and Find Full Text PDF

Background: Recent improvements in CT detector technology have led to smaller detector pixels resolving frequencies beyond 20 lp/cm and enabled ultra-high-resolution CT. Silicon-based photon-counting detector (PCD) CT is one such technology that promises improved spatial and spectral resolution. However, when the detector pixel sizes are reduced, the impact of cardiac motion on CT images becomes more pronounced.

View Article and Find Full Text PDF

Photon-counting computed tomography (PCCT) is an emerging technology promising to substantially improve cardiovascular imaging. Recent engineering and manufacturing advances by several vendors are expected to imminently launch this new technology into clinical reality. Photon-counting detectors (PCDs) have multiple potential advantages over conventional energy integrating detectors (EIDs) such as the absence of electronic noise, multi-energy capability, and increased spatial resolution.

View Article and Find Full Text PDF

Impending major hardware advances in cardiac CT include three areas: ultra-high-resolution (UHR) CT, photon-counting CT, and phase-contrast CT. Cardiac CT is a particularly demanding CT application that requires a high degree of temporal resolution, spatial resolution, and soft-tissue contrast in a moving structure. In this review, cardiac CT is used to highlight the strengths of these technical advances.

View Article and Find Full Text PDF

To evaluate the performance of photon-counting detector (PCD) computed tomography (CT) for coronary artery calcium (CAC) score imaging at standard and reduced radiation doses compared to conventional energy-integrating detector (EID) CT. A dedicated cardiac CT phantom, ten ex vivo human hearts, and ten asymptomatic volunteers underwent matched EID and PCD CT scans at different dose settings without ECG gating. CAC score, contrast, and contrast-to-noise ratio (CNR) were calculated in the cardiac CT phantom.

View Article and Find Full Text PDF

Purpose: To evaluate the performance and clinical feasibility of 0.25 mm resolution mode of a dual-energy photon-counting detector (PCD) computed tomography (CT) system for coronary stent imaging and to compare the results to state-of-the-art dual-energy energy-integrating detector (EID) CT.

Materials And Methods: Coronary stents with different diameters (2.

View Article and Find Full Text PDF

Photon-counting CT is an emerging technology with the potential to dramatically change clinical CT. Photon-counting CT uses new energy-resolving x-ray detectors, with mechanisms that differ substantially from those of conventional energy-integrating detectors. Photon-counting CT detectors count the number of incoming photons and measure photon energy.

View Article and Find Full Text PDF

Background: CT SQUEEZ is a new automated technique to evaluate regional endocardial strain by tracking features on the endocardium from 4D cine CT data. The objective of this study was to measure the range of endocardial regional strain (RS) values obtained with CT SQUEEZ in the normal human left ventricle (LV) from standard clinical 4D coronary CTA exams.

Methods: RS was measured over the heart cycle in 25 humans with normal LV function using cine CT from three vendors.

View Article and Find Full Text PDF

Recent improvements in cardiac computed tomography (CCT) allow for whole-heart functional studies to be acquired at low radiation dose (<2mSv) and high-temporal resolution (<100ms) in a single heart beat. Although the extraction of regional functional information from these images is of great clinical interest, there is a paucity of research into the quantification of regional function from CCT, contrasting with the large body of work in echocardiography and cardiac MR. Here we present the Simultaneous Subdivision Surface Registration (SiSSR) method: a fast, semi-automated image analysis pipeline for quantifying regional function from contrast-enhanced CCT.

View Article and Find Full Text PDF

Purpose: The aim of this study was to assess the clinical feasibility, image quality, and radiation dose implications of 0.25-mm imaging mode in a cohort of humans, achieved by dividing the photon-counting detector (PCD) size in half compared with standard-resolution photon-counting computed tomography (CT) (0.5 mm).

View Article and Find Full Text PDF

Resting regional wall motion abnormality (RWMA) has significant prognostic value beyond the findings of computed tomography (CT) coronary angiography. Stretch quantification of endocardial engraved zones (SQUEEZ) has been proposed as a measure of regional cardiac function. The purpose of the work reported here was to determine the effect of lowering the radiation dose on the precision of automatic SQUEEZ assessments of RWMA.

View Article and Find Full Text PDF

Purpose: To determine whether the type of VHL gene pathogenic variant influences the growth rate or CT enhancement values of renal lesions in VHL patients.

Materials And Methods: Thirty-two VHL patients (19 male) were selected from a prospectively maintained imaging database for patients that underwent surgical tumor resection between 2014 and 2016. One hundred and eleven VHL lesions were marked for resection and pathology analysis.

View Article and Find Full Text PDF

Purpose: To determine whether objective volumetric whole-lesion apparent diffusion coefficient (ADC) distribution analysis improves upon the capabilities of conventional subjective small region-of-interest (ROI) ADC measurements for prediction of renal cell carcinoma (RCC) subtype.

Methods: This IRB-approved study retrospectively enrolled 55 patients (152 tumors). Diffusion-weighted imaging DWI was acquired at b values of 0, 250, and 800 s/mm on a 1.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs).

Methods: In this institutional review board-approved study, 16 asymptomatic subjects (7 men) provided informed consent and received both PCD and EID contrast-enhanced CT scans of the head and neck (mean age, 58 years; range, 46-75 years). Tube settings were (EID: 120 kVp/160 mA vs PCD: 140 kVp/108 mA) for all volunteers.

View Article and Find Full Text PDF

Purpose To investigate whether photon-counting detector (PCD) technology can improve dose-reduced chest computed tomography (CT) image quality compared with that attained with conventional energy-integrating detector (EID) technology in vivo. Materials and Methods This was a HIPAA-compliant institutional review board-approved study, with informed consent from patients. Dose-reduced spiral unenhanced lung EID and PCD CT examinations were performed in 30 asymptomatic volunteers in accordance with manufacturer-recommended guidelines for CT lung cancer screening (120-kVp tube voltage, 20-mAs reference tube current-time product for both detectors).

View Article and Find Full Text PDF

Background: Optimal lead positioning is an important determinant of cardiac resynchronization therapy (CRT) response.

Objective: The purpose of this study was to evaluate cardiac computed tomography (CT) selection of the optimal epicardial vein for left ventricular (LV) lead placement by targeting regions of late mechanical activation and avoiding myocardial scar.

Methods: Eighteen patients undergoing CRT upgrade with existing pacing systems underwent preimplant electrocardiogram-gated cardiac CT to assess wall thickness, hypoperfusion, late mechanical activation, and regions of myocardial scar by the derivation of the stretch quantifier for endocardial engraved zones (SQUEEZ) algorithm.

View Article and Find Full Text PDF

Purpose: To demonstrate the feasibility of spectral imaging using photon-counting detector (PCD) x-ray computed tomography (CT) for simultaneous material decomposition of three contrast agents in vivo in a large animal model.

Methods: This Institutional Animal Care and Use Committee-approved study used a canine model. Bismuth subsalicylate was administered orally 24-72 h before imaging.

View Article and Find Full Text PDF