Publications by authors named "Amir Asif"

Deep learning-based Hand Gesture Recognition (HGR) via surface Electromyogram (sEMG) signals have recently shown considerable potential for development of advanced myoelectric-controlled prosthesis. Although deep learning techniques can improve HGR accuracy compared to their classical counterparts, classifying hand movements based on sparse multichannel sEMG signals is still a challenging task. Furthermore, existing deep learning approaches, typically, include only one model as such can hardly extract representative features.

View Article and Find Full Text PDF

Recent advancements in Electroencephalographic (EEG) sensor technologies and signal processing algorithms have paved the way for further evolution of Brain Computer Interfaces (BCI) in several practical applications, ranging from rehabilitation systems to smart consumer technologies. When it comes to Signal Processing (SP) for BCI, there has been a surge of interest on Steady-State motion Visual Evoked Potentials (SSmVEP), where motion stimulation is used to address key issues associated with conventional light flashing/flickering. Such benefits, however, come with the price of being less accurate and having a lower Information Transfer Rate (ITR).

View Article and Find Full Text PDF

Deep learning for ultrasound image formation is rapidly garnering research support and attention, quickly rising as the latest frontier in ultrasound image formation, with much promise to balance both image quality and display speed. Despite this promise, one challenge with identifying optimal solutions is the absence of unified evaluation methods and datasets that are not specific to a single research group. This article introduces the largest known international database of ultrasound channel data and describes the associated evaluation methods that were initially developed for the challenge on ultrasound beamforming with deep learning (CUBDL), which was offered as a component of the 2020 IEEE International Ultrasonics Symposium.

View Article and Find Full Text PDF

This work is motivated by the recent advances in Deep Neural Networks (DNNs) and their widespread applications in human-machine interfaces. DNNs have been recently used for detecting the intended hand gesture through the processing of surface electromyogram (sEMG) signals. Objective: Although DNNs have shown superior accuracy compared to conventional methods when large amounts of data are available for training, their performance substantially decreases when data are limited.

View Article and Find Full Text PDF

Background And Objective: Beamforming in coherent plane-wave compounding (CPWC) is an essential step in maintaining high resolution, contrast and framerate. Adaptive methods have been designed to achieve this goal by estimating the apodization weights from echo traces acquired by several transducer elements.

Methods: Herein, we formulate plane-wave beamforming as a blind source separation problem, where the output of each transducer element is considered as a non-independent observation of the field.

View Article and Find Full Text PDF

Ultrasound elastography (USE) is an emerging noninvasive imaging technique in which pathological alterations can be visualized by revealing the mechanical properties of the tissue. Estimating tissue displacement in all directions is required to accurately estimate the mechanical properties. Despite capabilities of elastography techniques in estimating displacement in both axial and lateral directions, estimation of axial displacement is more accurate than lateral direction due to higher sampling frequency, higher resolution, and having a carrier signal propagating in the axial direction.

View Article and Find Full Text PDF

Ultrasound elastography is a non-invasive technique for detecting pathological alterations in tissue. It is known that pathological alteration of tissue often has a direct impact on its elastic modulus, which can be revealed using elastography. For estimating elastic modulus, we need to estimate both axial and lateral displacement accurately.

View Article and Find Full Text PDF

In ultrasound imaging, there is a trade-off between imaging depth and axial resolution because of physical limitations. Increasing the center frequency of the transmitted ultrasound wave improves the axial resolution of resulting image. However, High Frequency (HF) ultrasound has a shallower depth of penetration.

View Article and Find Full Text PDF

Motivated by the inconceivable capability of human brain in simultaneously processing multi-modal signals and its real-time feedback to the outer world events, there has been a surge of interest in establishing a communication bridge between the human brain and a computer, which are referred to as Brain-computer Interfaces (BCI). To this aim, monitoring the electrical activity of brain through Electroencephalogram (EEG) has emerged as the prime choice for BCI systems. To discover the underlying and specific features of brain signals for different mental tasks, a considerable number of research works are developed based on statistical and data-driven techniques.

View Article and Find Full Text PDF

This article proposes a resilient framework for optimized consensus using a dynamic event-triggering (DET) scheme, where the multiagent system (MAS) is subject to denial-of-service (DoS) attacks. When initiated by an adversary, DoS blocks the local and neighboring communication channels in the network. A distributed DET scheme is utilized to limit transmissions between the neighboring agents.

View Article and Find Full Text PDF

Free-hand palpation ultrasound elastography is a noninvasive approach for detecting pathological alteration in tissue. In this method, the tissue is compressed by a handheld probe and displacement of each sample is estimated, a process which is also known as time-delay estimation (TDE). Even with the simplifying assumption that ignores out of plane motion, TDE is an ill-posed problem requiring estimation of axial and lateral displacements for each sample from its intensity.

View Article and Find Full Text PDF

This paper introduces a novel technique to estimate tissue displacement in quasi-static elastography. A major challenge in elastography is estimation of displacement (also referred to time-delay estimation) between pre-compressed and post-compressed ultrasound data. Maximizing normalized cross correlation (NCC) of ultrasound radio-frequency (RF) data of the pre- and post-compressed images is a popular technique for strain estimation due to its simplicity and computational efficiency.

View Article and Find Full Text PDF

A major challenge of free-hand palpation ultrasound elastography (USE) is estimating the displacement of RF samples between pre- and post-compressed RF data. The problem of displacement estimation is ill-posed since the displacement of one sample by itself cannot be uniquely calculated. To resolve this problem, two categories of methods have emerged.

View Article and Find Full Text PDF

Ultrasound elastography is a convenient and affordable method for imaging mechanical properties of tissue, which are often correlated with pathologies. An emerging novel elastography technique applies an external acoustic radiation force to generate a shear wave in the tissue and uses ultrasound imaging to track the shear wave. Accurate tracking of the small tissue motion is a critical step in shear-wave elastography (SWE), but it is challenging due to various sources of noise in the ultrasound data.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionjogt1qs06q82brvc8ivqrj1lc0gnuipi): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once