Publications by authors named "Amilcar C Freitas Junior"

To evaluate the stress behavior of ceramic fragment restoration, varying the thickness of the cement layer and intraoral temperature variation. A solid model of a upper lateral incisor was obtained and a defect at enamel distal/incisal edge was restored with a ceramic fragment. Based on this initial model, 4 different models (M) were built: M1 - absence of cement layer (CL) (0 μm of thickness); M2 - CL with an uniform thickness of 50 μm; M3 - CL with 50 μm at the margin of ceramics and 100 μm in the inner area far from margins; M4 - CL with 50 μm at the margin of ceramics and 200 μm in the inner area far from margins.

View Article and Find Full Text PDF

Objective: The aim of the present study was to analyze the influence of root canal and glass fiber post diameters on the biomechanical behavior of the dentin/cement/post interface of a root-filled tooth using 3D finite element analysis.

Material And Methods: Six models were built using micro-CT imaging data and SolidWorks 2007 software, varying the root canal (C) and the glass fiber post (P) diameters: C1P1-C=1 mm and P=1 mm; C2P1-C=2 mm and P=1 mm; C2P2-C=2 mm and P=2 mm; C3P1-C=3 mm and P=1 mm; C3P2-C=3 mm and P=2 mm; and C3P3-C=3 mm and P=3 mm. The numerical analysis was conducted with ANSYS Workbench 10.

View Article and Find Full Text PDF

Purpose: This study compared the biomechanical behavior of tilted long implant and vertical short implants to support fixed prosthesis in an atrophic maxilla.

Materials And Methods: The maxilla model was built based on a tomographic image of the patient. Implant models were based on micro-computer tomography imaging of implants.

View Article and Find Full Text PDF

Objectives: The non-homogenous aspect of periodontal ligament (PDL) has been examined using finite element analysis (FEA) to better simulate PDL behavior. The aim of this study was to assess, by 2-D FEA, the influence of non-homogenous PDL on the stress distribution when the free-end saddle removable partial denture (RPD) is partially supported by an osseointegrated implant.

Material And Methods: Six finite element (FE) models of a partially edentulous mandible were created to represent two types of PDL (non-homogenous and homogenous) and two types of RPD (conventional RPD, supported by tooth and fibromucosa; and modified RPD, supported by tooth and implant [10.

View Article and Find Full Text PDF

Step-stress accelerated life testing (SSALT) and fractographic analysis were performed to evaluate the reliability and failure modes of dental implant fabricated by machining (surface treated with alumina blasting/acid etching) or laser sintering for anterior single-unit replacements. Forty-two dental implants (3.75 × 10 mm) were divided in two groups (n=21 each): laser sintered (LS) and alumina blasting/acid etching (AB/AE).

View Article and Find Full Text PDF

Objectives: The aim of this study was to assess the effect of abutment's diameter shifting on reliability and stress distribution within the implant-abutment connection for internal and external hexagon implants. The postulated hypothesis was that platform-switched implants would result in increased stress concentration within the implant-abutment connection, leading to the systems' lower reliability.

Methods: Eighty-four implants were divided in four groups (n=21): REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively).

View Article and Find Full Text PDF

Objective: Biological and mechanical implant-abutment connection complications and failures are still present in clinical practice, frequently compromising oral function. The purpose of this study was to evaluate the reliability and failure modes of anterior single-unit restorations in internal conical interface (ICI) implants using step-stress accelerated life testing (SSALT).

Materials And Methods: Forty-two ICI implants were distributed in two groups (n = 21 each): group AT-OsseoSpeed(™) TX (Astra Tech, Waltham, MA, USA); group SV-Duocon System Line, Morse Taper (Signo Vinces Ltda.

View Article and Find Full Text PDF

Objectives: This study evaluated the reliability and failure modes of implants with a microthreaded or smooth design at the crestal region, restored with screwed or cemented crowns. The postulated null hypothesis was that the presence of microthreads in the implant cervical region would not result in different reliability and strength to failure than smooth design, regardless of fixation method, when subjected to step-stress accelerated life-testing (SSALT) in water.

Materials And Methods: Eighty four dental implants (3.

View Article and Find Full Text PDF

The alveolar ridge shape plays an important role in predicting the demand on the support tooth and alveolar bone in the removable partial denture (RPD) treatment. However, these data are unclear when the RPD is associated with implants. This study evaluated the influence of the alveolar ridge shape on the stress distribution of a free-end saddle RPD partially supported by implant using 2-dimensioanl finite element analysis (FEA).

View Article and Find Full Text PDF

The reliability and failure modes of molar crowns supported by three different implant-supported designs were tested according to the following groups: group 1, one standard-diameter implant (3.75 mm); group 2, one narrow-diameter implant (3 mm); and group 3, two narrow-diameter implants (3 mm). Loads were applied as mouth-motion cycles using a step-stress accelerated life-testing method.

View Article and Find Full Text PDF

Objectives: To evaluate the reliability and failure modes of regular and horizontal mismatched platforms for implant-abutment connection varying the implant diameter.

Material And Methods: Regular (REG, n = 21, 4.0-mm-diameter implant) and horizontal mismatched (HM, n = 21, 4.

View Article and Find Full Text PDF

Restoring a misaligned tooth with an inadequate contact point is a challenge to the practitioner. In some instances, teeth that could be repositioned and adequately restored are extracted. Thus, the aim of this article was to describe a treatment using orthodontic and prosthetic techniques to restore esthetics and function in a patient with a distally drifted maxillary lateral incisor.

View Article and Find Full Text PDF

The teeth most commonly affected by trauma are the maxillary central incisors. The most frequent types of traumatic dental injuries to permanent teeth are enamel fractures, enamel and dentine fractures, and enamel and dentine fractures with pulp involvement. This article describes three clinical cases with different levels of traumatized maxillary incisors and several cosmetic approaches for recovery of the esthetics and the masticatory function, as well as the social/psychological aspects of treatment.

View Article and Find Full Text PDF

The aim of this study was to evaluate the influence of the high values of insertion torques on the stress and strain distribution in cortical and cancellous bones. Based on tomography imaging, a representative mathematical model of a partial maxilla was built using Mimics 11.11 and Solid Works 2010 softwares.

View Article and Find Full Text PDF

The aim of this study was to analyze the main aspects that influence the aesthetics of single immediate implant-supported restorations through a literature review on the MEDLINE database. It was observed that immediate implant-supported restorations present clinical success with aesthetic predictability demonstrated by the literature. Proper patient selection and diagnostic and multidisciplinary planning are essential and should be associated to technical ability of professional and knowledge concerning the biology of periimplant tissues.

View Article and Find Full Text PDF

Unlabelled: The presence of porosities at the dentin/adhesive interface has been observed with the use of new generation dentin bonding systems. These porosities tend to contradict the concept that etching and hybridization processes occur equally and simultaneously. Therefore, the aim of this study was to evaluate the micromechanical behavior of the hybrid layer (HL) with voids based on a self-etching adhesive system using 3-D finite element (FE) analysis.

View Article and Find Full Text PDF