Objective: To study the feasibility and safety of removing retrievable Günther-Tulip vena cava filters (GTFs) 90 days after their implantation in an ovine model.
Material And Methods: Thirty GTFs were implanted in 30 ewes and retrieval was attempted at 90 days. Conventional cavography was performed in all cases before and after retrieval in order to evaluate inferior vena cava patency and record dimensions.
Objectives: The use of nanoparticules for drug transport is one of the topics with priority interest within the field of biomedical research. Our objective is to show the initial results of an innovative method to focalize drug carrier ferro-carbon nanoparticules to solid organs. We obtained and characterized various types of ferrous magnetic nanoparticules and studied their behaviour in vitro and in vivo in laboratory animals with intrarenal magnetic targets laparoscopically implanted.
View Article and Find Full Text PDFPurpose: To compare in a pilot study, the retrievability and inferior vena cava (IVC) wall reaction elicited by uncoated and paclitaxel-coated Günther-Tulip filters in the animal model.