Introduction: The purpose of this study is to assess the ability of two new ECG markers (Regional Repolarisation Instability Index (R2I2) and Peak Electrical Restitution Slope) to predict sudden cardiac death (SCD) or ventricular arrhythmia (VA) events in patients with ischaemic cardiomyopathy undergoing implantation of an implantable cardioverter defibrillator for primary prevention indication.
Methods And Analysis: Multicentre Investigation of Novel Electrocardiogram Risk markers in Ventricular Arrhythmia prediction is a prospective, open label, single blinded, multicentre observational study to establish the efficacy of two ECG biomarkers in predicting VA risk. 440 participants with ischaemic cardiomyopathy undergoing routine first time implantable cardioverter-defibrillator (ICD) implantation for primary prevention indication are currently being recruited.
We report the first leadless pacemaker (L-PM) providing atrioventricular synchronous pacing implanted into a heart transplant patient receiving chronic immunosuppressive therapy. The patient presented with syncope corresponding to sinus rhythm with high-grade atrioventricular block. Previously, L-PMs provided only single-chamber ventricular sensing and pacing.
View Article and Find Full Text PDFIdentifying targets for catheter ablation remains challenging in persistent atrial fibrillation (persAF). The dominant frequency (DF) of atrial electrograms during atrial fibrillation (AF) is believed to primarily reflect local activation. Highest DF (HDF) might be responsible for the initiation and perpetuation of persAF.
View Article and Find Full Text PDFObjective: There are large geographical differences in implantable cardioverter defibrillator (ICD) implantation rates for reasons not completely understood. In an increasingly multiethnic population, we sought out to investigate whether ethnicity influenced ICD implantation rates.
Methods: This was a retrospective, cohort study of new ICD implantation or upgrade to ICD from January 2006 to February 2019 in recipients of Caucasian or South Asian ethnicity at a single tertiary centre in the UK.
Purpose: Implantable cardioverter defibrillator (ICD) implantation rates remain variable despite established guideline recommendations. This study aims to assess whether being managed by a cardiologist has an impact on whether patients are considered for an ICD for primary prevention of sudden cardiac death.
Design/methods: Single-centre, retrospective, observational study of patients identified to have severe left ventricular systolic dysfunction (LVSD) on echocardiography (n = 129) between 1 and 30 June 2016 with cross-sectional assessment at 1 year.
Sudden cardiac death (SCD) is a major cause of mortality presenting a significant unmet clinical need. Patients at risk of SCD are implanted with implantable cardioverter-defibrillators (ICDs) according to international guidelines based on clinical trial evidence. Implantable cardioverter-defibrillators are not inexpensive and not without problem in terms of inappropriate shocks and infection risk.
View Article and Find Full Text PDF