We develop a novel hyperspectral imaging system using structured illumination in an SLM-based Michelson interferometer. In our design, we use a reflective SLM as a mirror in one of the arms of a Michelson interferometer and scan the interferometer by varying the phase across the SLM display. For achieving the latter, we apply a checkerboard phase mask on the SLM display where the gray value varies between 0-255, thereby imparting a dynamic phase of up to 262° to the incident light beam.