Liquid chromatography-mass spectrometry (LC-MS) has emerged as a powerful analytical technique for analyzing complex biological samples. Among various chromatographic stationary phases, porous graphitic carbon (PGC) columns have attracted significant attention due to their unique properties-such as the ability to separate both polar and non-polar compounds and their stability through all pH ranges and to high temperatures-besides the compatibility with LC-MS. This review discusses the applicability of PGC for SPE and separation in LC-MS-based analyses of human biological samples, highlighting the diverse applications of PGC-LC-MS in analyzing endogenous metabolites, pharmaceuticals, and biomarkers, such as glycans, proteins, oligosaccharides, sugar phosphates, and nucleotides.
View Article and Find Full Text PDFIntroduction: Pollution has emerged as a significant threat to humanity, necessitating a thorough evaluation of its impacts. As a result, various methods for human biomonitoring have been proposed as vital tools for assessing, managing, and mitigating exposure risks. Among these methods, urine stands out as the most commonly analyzed biological sample and the primary matrix for biomonitoring studies.
View Article and Find Full Text PDFPreparative liquid chromatography is a technique for separating complex samples or isolating pure compounds from complex extracts. It involves eluting samples through a packed column and selectively collecting or isolating the separated bands in a sequence of fractions. Depending on the column length and the sample complexity, a large number of fractions may be obtained, making fraction collection a laborious and time-consuming process.
View Article and Find Full Text PDFAn automated microextraction by packed sorbent followed by liquid chromatography-tandem mass spectrometry (MEPS-LC-MS/MS) method was developed for the determination of four endocrine disruptors-parabens, benzophenones, and synthetic phenolic antioxidants-in wastewater samples. The method utilizes a lab-made repackable MEPS device and a multi-syringe robotic platform that provides flexibility to test small quantities (2 mg) of multiple extraction phases and enables high-throughput capabilities for efficient method development. The overall performance of the MEPS procedure, including the investigation of influencing variables and the optimization of operational parameters for the robotic platform, was comprehensively studied through univariate and multivariate experiments.
View Article and Find Full Text PDFElectrophoresis
August 2022
Dynamic single-drop microextraction (SDME) was automatized employing an Arduino-based lab-made Cartesian robot and implemented to determine parabens in wastewater samples in combination with liquid chromatography-tandem mass spectrometry. A dedicated Arduino sketch controls the auto-performance of all the stages of the SDME process, including syringe filling, drop exposition, solvent recycling, and extract collection. Univariate and multivariate experiments investigated the main variables affecting the SDME performance, including robot-dependent and additional operational parameters.
View Article and Find Full Text PDFCannabinoids are pharmacologically active compounds present in cannabis plants, which have become important research topics in the modern toxicological and medical research fields. Not only is cannabis the most used drug globally, but also cannabinoids have a growing use to treat a series of diseases. Therefore, new, fast, and efficient analytical methods for analyzing these substances in different matrices are demanded.
View Article and Find Full Text PDFAn original, selective and automated method, for the microextraction by packed sorbent (MEPS) of Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH), and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) from human urine, was developed by using (i) a catechin-molded molecularly imprinted polymer (MIP), (ii) a new lab-made MEPS device easily repackable with any commercial or lab-made sorbent, and (iii) a lab-made multi syringe autosampler. Analyses were performed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the developed method proved to be precise, accurate and showed good linearity. Determination coefficients ranged from 0.
View Article and Find Full Text PDFThe present paper describes an original method for the online preconcentration and analysis of ring-substituted amphetamines in urine samples, used on the integration of robot-assisted hollow fiber liquid-phase microextraction (HF-LPME), high-performance liquid chromatography (HPLC), and fluorescence detection (FLD). A lab-made autosampler, actuating a 100-μL syringe and equipped with a three-way solenoid microvalve, allowed the acceptor phase to flow through and be withdrawn from the lumen fiber, enabling the automated online transference of the enriched acceptor phase for chromatographic analysis, through a six-port switching valve. The developed online HF-LPME-LC/FLD method demonstrated high analytical throughput and confidence, facilitating the efficient extraction and determination of the target analytes, with minimal solvent consumption and sample manipulation, in a straightforward way.
View Article and Find Full Text PDFBy proper design of an innovative extraction device, a lab-made multipurpose autosampler was exploited in the automated performance of the dynamic large drops based microextraction. The pluses of this new analytical strategy were demonstrated in the determination of sulfonamides and fluoroquinolones in surface water samples, by direct immersion single drop microextraction (SDME) and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis. Operational autosampler features and critical experimental factors influencing SDME, including the extraction mode (static or dynamic), extraction, stirring rate, salt addition, drop size, number of cycles and drop exposition time, were comprehensively investigated using both univariate and multivariate optimization.
View Article and Find Full Text PDFA high-throughput and innovative setup has been developed to automate the online integration of single drop microextraction (SDME), liquid chromatography (LC) and high-resolution mass spectrometry (QqToF). SDME and LC were online hyphenated for the first time. SDME was carried out by a lab-made cartesian robot actuating a 100 μL syringe, equipped with a three-way solenoid microvalve that allowed the online transference of the enriched extract to the chromatographic system, through a six-port switching valve.
View Article and Find Full Text PDFIn this work, the dispersive liquid-liquid microextraction technique based on the solidification of the organic phase (DLLME-SFO) has been automated for the first time. DLLME-SFO is automated by hyphenating a sequential injection analysis (SIA) system with a custom-made robotic phase separator. Automated in-syringe DLLME is followed by phase separation in a 3D printed device integrating a Peltier cell set, mounted on a multi-axis robotic arm.
View Article and Find Full Text PDFAnalyst
November 2015
Molecularly imprinting polymers (MIPs) can be modified with external layers in order to obtain restricted access molecularly imprinted polymers (RAMIPs) able to exclude macromolecules and retain low weight compounds. These modifications have been frequently achieved using hydrophilic monomers, chemically bound on the MIP surface. Recently, our group proposed a new biocompatible RAMIP based on the formation of a bovine serum albumin coating on the surface of MIP particles.
View Article and Find Full Text PDFMolecularly imprinted polymers for the determination of triazines were synthesized by precipitation using atrazine as template, methacrylic acid as functional monomer, ethylene glycol dimethacrylate as crosslinker, and 2,2'-azobisisobutrynitrile as initiator. The polymers were characterized by infrared spectroscopy and scanning electron microscopy and packed in a device for microextraction by packed sorbent aiming for the preconcentration/cleanup of herbicides, such as atrazine, simazine, simetryn, ametryn, and terbutryn in corn samples. Liquid chromatography coupled with time-of-flight mass spectrometry was used for the separation and determination of the herbicides.
View Article and Find Full Text PDFAnal Bioanal Chem
September 2013
A new restricted access molecularly imprinted polymer coated with bovine serum albumin (RAMIP-BSA) was developed, characterized, and used for direct analysis of chlorpromazine in human plasma samples. The RAMIP-BSA was synthesized using chlorpromazine, methacrylic acid, and ethylene glycol dimethacrylate as template, functional monomer, and cross-linker, respectively. Glycerol dimethacrylate and hydroxy methyl methacrylate were used to promote a hydrophilic surface (high density of hydroxyl groups).
View Article and Find Full Text PDFA two-phase liquid phase microextraction using a hollow fiber combined with injection port derivatization and gas chromatographic analysis was developed for extracting and detecting fluoxetine (FLU) and norfluoxetine (NOR) in human plasma. Simultaneous extraction in a multiple tube shaker was used and, afterward, the organic phase was simply injected together with the derivatizing agent n-methyl-bis(trifluoroacetamide) (MBTFA). Factors influencing injection port derivatization, and several extraction parameters were optimized.
View Article and Find Full Text PDFJ Sep Sci
February 2011
This paper presents the development of a procedure, which enables the analysis of nine pharmaceutical drugs in wastewater using gas chromatography-mass spectrometry (GC-MS) associated with solid-phase microextraction (SPME) for the sample preparation. Experimental design was applied to optimize the in situ derivatization and the SPME extraction conditions. Ethyl chloroformate (ECF) was employed as derivatizing agent and polydimethylsiloxane-divinylbenzene (PDMS-DVB) as the SPME fiber coating.
View Article and Find Full Text PDFSolid-phase microextraction (SPME)-liquid chromatography (LC) is used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. Extraction conditions are optimized using a 2(3) factorial design plus a central point to evaluate the influence of the time, temperature, and matrix pH. A Polydimethylsiloxane-divinylbenzene (60-mum film thickness) fiber is selected after the assessment of different types of coating.
View Article and Find Full Text PDF