Publications by authors named "Alphons Tonino"

In total hip arthroplasty (THA) Technetium scintigraphy can help to diagnose a loose implant by detecting elevated osteoblastic activity. It has been used for timing the revision of cemented implants. In uncemented cups progressive radiological acetabular osteolysis can be present before loosening accurs, but it is probably unwise to await cup loosening before embarking on revision.

View Article and Find Full Text PDF

Unlabelled: Wear particle-induced osteolysis is a major cause of aseptic loosening in THA. Increasing wear resistance of polyethylene (PE) occurs by increasing the cross-link density and early reports document low wear rates with such implants. To confirm longer-term reductions in wear we compared cross-linked polyethylene (irradiation in nitrogen, annealing) with historical polyethylene (irradiation in air) in a prospective, randomized clinical study involving 48 patients who underwent THAs with a minimum followup of 7 years (mean, 8 years; range, 7-9 years).

View Article and Find Full Text PDF

Hydroxyapatite coatings for THA promote bone ongrowth, but bone and coating are exposed to stress shielding-driven osteoclastic resorption. We asked: (1) if the resorption of hydroxyapatite coating and bone ongrowth correlated with demographics; (2) if the resorption related to the stem level; and (3) what happens to the implant-bone interface when all hydroxyapatite coating is resorbed? We recovered 13 femoral components from cadaveric specimens 3.3 to 11.

View Article and Find Full Text PDF

This study describes our experience with a hydroxyapatite-coated uncemented hemispherical component used for revision of 72 patients with aseptic loosening of the acetabular component. Preoperative Paprosky classification of the acetabular defects was 1 type I, 35 type II, and 36 type III; according to American Academy of Orthopaedic Surgeons, 14 segmental, 10 cavitary, and 48 combined. The mean follow-up was 7.

View Article and Find Full Text PDF

Recently it was shown that the design changes from the ABG-I to ABG-II hip stem resulted in a better, although not significant, proximal bone preservation. Our hypothesis was that by matching patients for preoperative bone quality, statistical power would increase and that the trend of better proximal bone preservation in ABG-II might become significant. Twenty-four ABG-II patients were compared to two different ABG-I groups: (1) 25 patients from our earlier prospective study and (2) a group of 24 patients selected to perfectly match the ABG-II group regarding gender, age and preoperative bone quality.

View Article and Find Full Text PDF

Background: Polyethylene wear-induced osteolysis is a major cause of implant loosening in total hip arthroplasty. New crosslinked polyethylenes are presumed to give lower wear rates, but no long-term clinical results are available yet.

Patients And Methods: We compared basic material characteristics and MTS hip joint simulator wear rates of a crosslinked polyethylene (Duration) to those of conventional polyethylene.

View Article and Find Full Text PDF

Hypothetically, hydroxyapatite-coated anatomic-shaped femoral stems and hemispheric acetabular cups should improve biologic fixation of the implant and strength transmission to the bone, improving unsatisfactory results of the first cementless hip prosthesis focused on the stress-shielding phenomenon at the femur and failure of the threaded acetabular cups. A consecutive series of 312 patients who had primary Anatomique Benoist Giraud hip prostheses unilaterally implanted were followed up. We analyzed the clinical and radiographic results and report the outcomes 7-10 years after implantation.

View Article and Find Full Text PDF

We followed 100 consecutive primary total hip replacements with a proximal hydroxyapatite coating for 10 years. No patient was lost to follow-up. 29 patients (32 hips) died before the 10-year follow-up was done; none of their hips had been revised.