Objectives: The numbers of computed tomography (CT) and magnetic resonance imaging (MRI) examinations per capita continue to increase in Sweden and in other parts of Europe. The appropriateness of CT and MRI examinations was audited using established European appropriateness criteria. Alternative modalities were also explored.
View Article and Find Full Text PDFIndividual monitoring of radiation workers is essential to ensure compliance with legal dose limits and to ensure that doses are As Low As Reasonably Achievable. However, large uncertainties still exist in personal dosimetry and there are issues with compliance and incorrect wearing of dosimeters. The objective of the PODIUM (Personal Online Dosimetry Using Computational Methods) project was to improve personal dosimetry by an innovative approach: the development of an online dosimetry application based on computer simulations without the use of physical dosimeters.
View Article and Find Full Text PDFRadiation dosimetry is central to virtually all radiation safety applications, optimization, and research. It relates to various individuals and population groups and to miscellaneous exposure situations-including planned, existing, and emergency situations. The International Commission on Radiological Protection (ICRP) has developed a new computational framework for internal dose estimations.
View Article and Find Full Text PDFDiatoms commonly set off the spring-bloom in temperate coastal environments. However, their temporal offset may change in regions subject to nutrient enrichment, and by peaking earlier, such populations can maintain their position in the vernal plankton succession. We tested whether the marine keystone diatom Skeletonema marinoi can accomplish this through thermal evolutionary adaptation.
View Article and Find Full Text PDFObjective: The purpose of this study was to explore the feasibility to determine regional diagnostic reference levels (RDRLs) for paediatric conventional and CT examinations using the European guidelines and to compare RDRLs derived from weight and age groups, respectively.
Methods: Data were collected from 31 hospitals in 4 countries, for 7 examination types for a total of 2978 patients. RDRLs were derived for each weight and age group, respectively, when the total number of patients exceeded 15.
Background: There is a continuous and dynamic discussion on artificial intelligence (AI) in present-day society. AI is expected to impact on healthcare processes and could contribute to a more sustainable use of resources allocated to healthcare in the future. The aim for this work was to establish a foundation for a Swedish perspective on the potential effect of AI on the medical physics profession.
View Article and Find Full Text PDFPurpose: To derive Regional Diagnostic Reference Levels (RDRL) for paediatric conventional and CT examinations using weight-based DRL curves and compare the outcome with DRL derived using the weight groups.
Methods: Data from 1722 examinations performed at 29 hospitals in four countries were included. DRL was derived for four conventional x-ray (chest, abdomen, pelvis, hips/joints) and two types of CT examinations (thorax, abdomen).
Unlabelled: The aim of this study is to implement lifetime attributable risk (LAR) predictions for radiation induced cancers for Swedish cohorts of patients of various age and sex, undergoing diagnostic investigations by nuclear medicine methods.
Methods: Calculations are performed on Swedish groups of patients with Paget's disease and with bone metastases from prostatic cancer and diagnosed with bone scintigraphy with an administration of 500 MBq 99mTc-phosphonate.
Results: The inclusion of patient survival rates into the calculations lowers the induced radiation cancer risk, as it takes into account that cohorts of patients have shorter predicted survival times than the general population.
Imaging optimisation can benefit from combining structured data with qualitative data in the form of audio and video recordings. Since video is complex to work with, there is a need to find a workable solution that minimises the additional time investment. The purpose of the paper is to outline a general workflow that can begin to address this issue.
View Article and Find Full Text PDFPurpose: Interventional radiology techniques cause radiation exposure both to patient and personnel. The radiation dose to the operator is usually measured with dosimeters located at specific points above or below the lead aprons. The aim of this study is to develop and validate two fast Monte Carlo (MC) codes for radiation transport in order to improve the assessment of individual doses in interventional radiology.
View Article and Find Full Text PDFThe present study focuses on introducing the concept of optimisation and proposing a model, including evaluation of image quality, to be used in the clinical routines where image-guided intervention is being performed. The overall aim of the study was to develop a model for evaluating the use of imaging in X-ray-guided interventional procedures and its possible implications on optimisation of radiation protection. In the search for an adequate evaluation model, data from endovascular interventions of the aorta (EVAR procedures) were used.
View Article and Find Full Text PDFExposure levels to staff in interventional radiology (IR) may be significant and appropriate assessment of radiation doses is needed. Issues regarding measurements using physical dosemeters in the clinical environment still exist. The objective of this work was to explore the prerequisites for assessing staff radiation dose, based on simulations only.
View Article and Find Full Text PDFEnzymes play important roles in many biological processes. Amino acid residues in the active site pocket of an enzyme, which are in direct contact with the substrate(s), are generally believed to be critical for substrate recognition and catalysis. Identifying and understanding how these "catalytic" residues help enzymes achieve enormous rate enhancement has been the focus of many structural and biochemical studies over the past several decades.
View Article and Find Full Text PDFAs a measure to prepare for long-term internal dose monitoring of workers at the European Spallation Source (ESS) in Lund, Sweden, operated by the European Research Infrastructure Consortium (ERIC), as well as to enhance emergency preparedness against accidental releases, a series of in vivo measurements were conducted using a high-resolution HPGe detector with a 123% relative efficiency (1.332 MeV). This study describes the whole-body counting set-up, calibration procedure, and subsequent validation measurements using conventional NaI(Tl)-scanning-bed geometry on a selection of workers from the ESS.
View Article and Find Full Text PDFThe present work explores challenges when assessing organ dose and effective dose concerning image-guided treatments. During these treatments considerable x-ray imaging is employed using technically advanced angiographic x-ray equipment. Thus, the radiation dose to organs and the related radiation risk are relatively difficult to assess.
View Article and Find Full Text PDFThis paper describes issues of concern for protecting foetuses and breast-fed children of occupationally exposed women in nuclear medicine from unnecessary exposure of ionising radiation. The protection principle is to ensure the same level of protection for the foetus and child as for the general public. Therefore international radiation protection standards recommend a dose constraint of 1mSv to a foetus during the remaining time of pregnancy after it is known/declared and a yearly dose constraint of 1mSv to a breast-fed child.
View Article and Find Full Text PDFWe studied changes in sea water pH, temperature and salinity with focus on two depth layers, along the Gulf of Finland (the Baltic Sea) using long-term monitoring data from 1979 to 2015. Data from the most frequently sampled monitoring stations between western and eastern Gulf of Finland were used. The main result of the study reveals that pH has decreased both in surface and deep-water in the western Gulf of Finland with values ranging between -0.
View Article and Find Full Text PDFRadiat Prot Dosimetry
November 2016
The overall purpose of this work was to explore how video recordings can contribute to the process of optimising occupational radiation protection in image-guided interventions. Video-recorded material from two image-guided interventions was produced and used to investigate to what extent it is conceivable to observe and assess dose-affecting actions in video recordings. Using the recorded material, it was to some extent possible to connect the choice of imaging techniques to the medical events during the procedure and, to a less extent, to connect these technical and medical issues to the occupational exposure.
View Article and Find Full Text PDFThe overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined.
View Article and Find Full Text PDFDoses to the eyes of interventional clinicians can exceed 20 mSv. Various protective devices can afford protection to the eyes with the final barrier being protective eyewear. The protection provided by lead glasses is difficult to quantify, and the majority of dosimeters are not designed to be worn under lead glasses.
View Article and Find Full Text PDFThe optimisation of occupational radiological protection is challenging and a variety of factors have to be considered. Physicians performing image-guided interventions are working in an environment with one of the highest radiation risk levels in healthcare. Appropriate knowledge about the radiation environment is a prerequisite for conducting the optimisation process.
View Article and Find Full Text PDFRadiat Prot Dosimetry
April 2015
Quality assurance has been identified as an important part of radiation protection and safety for a considerable time period. A rational expansion and improvement of quality assurance is to integrate radiation protection and safety in a management system. The aim of this study was to explore factors influencing the implementing strategy when introducing a management system including radiation protection and safety in hospitals and to outline benefits of such a system.
View Article and Find Full Text PDFDoses to the eyes of interventional radiologists and cardiologists could exceed the annual limit of 20 mSv proposed by the International Commission on Radiological Protection. Lead glasses of various designs are available to provide protection, but standard eye dosemeters will not take account of the protection they provide. The aim of this study has been to derive dose reduction factors (DRFs) equal to the ratio of the dose with no eyewear, divided by that when lead glasses are worn.
View Article and Find Full Text PDFOptimisation of radiological protection for operators working with fluoroscopically guided procedures has to be performed during the procedure, under varying and difficult conditions. The aim of the present study was to evaluate the impact of a system for real-time visualisation of radiation dose rate on optimisation of occupational radiological protection in fluoroscopically guided procedures. Individual radiation dose measurements, using a system for real-time visualisation, were performed in a cardiology laboratory for three cardiologists and ten assisting nurses.
View Article and Find Full Text PDF