Publications by authors named "Alix O Paget-Brown"

Objective: In 2006 the apnea of prematurity (AOP) consensus group identified inaccurate counting of apnea episodes as a major barrier to progress in AOP research. We compare nursing records of AOP to events detected by a clinically validated computer algorithm that detects apnea from standard bedside monitors.

Study Design: Waveform, vital sign, and alarm data were collected continuously from all very low-birth-weight infants admitted over a 25-month period, analyzed for central apnea, bradycardia, and desaturation (ABD) events, and compared with nursing documentation collected from charts.

View Article and Find Full Text PDF

Background: Infants admitted to the neonatal intensive care unit (NICU), and especially those born with very low birth weight (VLBW; <1,500 g), are at risk for respiratory decompensation requiring endotracheal intubation and mechanical ventilation. Intubation and mechanical ventilation are associated with increased morbidity, particularly in urgent unplanned cases.

Methods: We tested the hypothesis that the systemic response associated with respiratory decompensation can be detected from physiological monitoring and that statistical models of bedside monitoring data can identify infants at increased risk of urgent unplanned intubation.

View Article and Find Full Text PDF

Apnea of prematurity is an important and common clinical problem, and is often the rate-limiting process in NICU discharge. Accurate detection of episodes of clinically important neonatal apnea using existing chest impedance (CI) monitoring is a clinical imperative. The technique relies on changes in impedance as the lungs fill with air, a high impedance substance.

View Article and Find Full Text PDF

Introduction: Measurement of pH is one of the simplest and most technically validated biomarkers studied in exhaled breath condensate (EBC). The pH of EBC has been found to be lower than controls in many respiratory disorders. Published data from normal control subjects have been reasonably consistent, but the data sets are not large.

View Article and Find Full Text PDF

Rationale And Objectives: The purpose of this study is to determine hyperpolarized helium 3 (HHe) magnetic resonance (MR) findings of the lung in patients with cystic fibrosis (CF) compared with healthy subjects and determine whether HHe MR can detect changes after bronchodilator therapy or mechanical airway mucus clearance treatment.

Materials And Methods: Thirty-one subjects, 16 healthy volunteers and 15 patients with CF, underwent HHe lung ventilation MR imaging and spirometry at baseline. Eight patients with CF then were treated with nebulized albuterol, after which a follow-up HHe MR scan was obtained.

View Article and Find Full Text PDF