Purpose: Image-based computational fluid dynamics (CFD) is widely used to predict intracranial aneurysm wall shear stress (WSS), particularly with the goal of improving rupture risk assessment. Nevertheless, concern has been expressed over the variability of predicted WSS and inconsistent associations with rupture. Previous challenges, and studies from individual groups, have focused on individual aspects of the image-based CFD pipeline.
View Article and Find Full Text PDFWith the increased availability of computational resources, the past decade has seen a rise in the use of computational fluid dynamics (CFD) for medical applications. There has been an increase in the application of CFD to attempt to predict the rupture of intracranial aneurysms, however, while many hemodynamic parameters can be obtained from these computations, to date, no consistent methodology for the prediction of the rupture has been identified. One particular challenge to CFD is that many factors contribute to its accuracy; the mesh resolution and spatial/temporal discretization can alone contribute to a variation in accuracy.
View Article and Find Full Text PDFIntroduction: The American Heart Association (AHA)/American College of Cardiology (ACC) guidelines for the classification of heart failure (HF) are descriptive but lack precise and objective measures which would assist in categorising such patients. Our aim was two fold, firstly to demonstrate quantitatively the progression of HF through each stage using a meta-analysis of existing left ventricular (LV) pressure-volume (PV) loop data and secondly use the LV PV loop data to create stage specific HF models.
Methods And Results: A literature search yielded 31 papers with PV data, representing over 200 patients in different stages of HF.
This study presents a numerical simulation of cardiovascular response in the heart failure condition under the support of a Berlin Heart INCOR impeller pump-type ventricular assist device (VAD). The model is implemented using the CellML modelling language. To investigate the potential of using the Berlin Heart INCOR impeller pump to produce physiologically meaningful arterial pulse pressure within the various physiological constraints, a series of VAD-assisted cardiovascular cases are studied, in which the pulsation ratio and the phase shift of the VAD motion profile are systematically changed to observe the cardiovascular responses in each of the studied cases.
View Article and Find Full Text PDFState of the art simulations of aortic haemodynamics feature full fluid-structure interaction (FSI) and coupled 0D boundary conditions. Such analyses require not only significant computational resource but also weeks to months of run time, which compromises the effectiveness of their translation to a clinical workflow. This article employs three computational fluid methodologies, of varying levels of complexity with coupled 0D boundary conditions, to simulate the haemodynamics within a patient-specific aorta.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
August 2012
Left ventricular assist devices (LVADs) are carefully designed, but the significance of the implantation configuration and interaction with the vasculature is complex and not fully determined. The present study employs computational fluid dynamics to investigate the importance of applying a realistic LVAD profile when evaluating assisted aortic flow fields and subsequently compares a number of potential anastomosis locations in a patient-specific aortic geometry. The outflow profile of the Berlin Heart INCOR® device was provided by Berlin Heart GmbH (Berlin, Germany) and the cannula was attached at a number of locations on the aorta.
View Article and Find Full Text PDF