Optoacoustic (OA) tomography is a powerful noninvasive preclinical imaging tool enabling high resolution whole-body visualization of biodistribution and dynamics of molecular agents. The technique yet lacks endogenous soft-tissue contrast, which often hampers anatomical navigation. Herein, we devise spiral volumetric optoacoustic and ultrasound (SVOPUS) tomography for concurrent OA and pulse-echo ultrasound (US) imaging of whole mice.
View Article and Find Full Text PDFNoninvasive monitoring of cardiac development can potentially prevent cardiac anomalies in adulthood. Mouse models provide unique opportunities to study cardiac development and disease in mammals. However, high-resolution noninvasive functional analyses of murine embryonic cardiac models are challenging because of the small size and fast volumetric motion of the embryonic heart, which is deeply embedded inside the uterus.
View Article and Find Full Text PDFOptoacoustic (OA) imaging has achieved tremendous progress with state-of-the-art systems providing excellent functional and molecular contrast, centimeter scale penetration into living tissues, and ultrafast imaging performance, making it highly suitable for handheld imaging in the clinics. OA can greatly benefit from efficient integration with ultrasound (US) imaging, which remains the routine method in bedside clinical diagnostics. However, such integration has not been straightforward since the two modalities typically involve different image acquisition strategies.
View Article and Find Full Text PDFTendon injuries resulting from accidents and aging are increasing globally. However, key tendon functional parameters such as microvascularity and oxygen perfusion remain inaccessible via the currently available clinical diagnostic tools, resulting in disagreements on optimal treatment options. Here, a new noninvasive method for anatomical and functional characterization of human tendons based on multispectral optoacoustic tomography (MSOT) is reported.
View Article and Find Full Text PDFSignificance: An array of techniques for targeted neuromodulation is emerging, with high potential in brain research and therapy. Calcium imaging or other forms of functional fluorescence imaging are central solutions for monitoring cortical neural responses to targeted neuromodulation, but often are confounded by thermal effects that are inter-mixed with neural responses.
Aim: Here, we develop and demonstrate a method for effectively suppressing fluorescent thermal transients from calcium responses.
IEEE Trans Med Imaging
October 2022
Optoacoustic tomography (OAT) has recently been advanced toward ultrafast volumetric imaging frame rates in the kilohertz range. As a result, excessive data processing and storage capacity requirements are increasingly being imposed on the imaging systems. OAT data commonly exhibit significant sparsity across the spatial, temporal or spectral domains, which facilitated the development of compressed sensing algorithms exploiting various sparse acquisition and under-sampling schemes to reduce data rates.
View Article and Find Full Text PDFUnderstanding the physiological impact of transcranial ultrasound in rodent brains may offer an important preclinical model for human scale magnetic resonance–guided focused ultrasound methods. However, precision tools for high-resolution transcranial ultrasound targeting and real-time in vivo tracking of its effects at the mouse brain scale are currently lacking. We report a versatile bidirectional hybrid fluorescence-ultrasound (FLUS) system incorporating a 0.
View Article and Find Full Text PDFSpherical matrix arrays represent an advantageous tomographic detection geometry for non-invasive deep tissue mapping of vascular networks and oxygenation with volumetric optoacoustic tomography (VOT). Hybridization of VOT with ultrasound (US) imaging remains difficult with this configuration due to the relatively large inter-element pitch of spherical arrays. We suggest a new approach for combining VOT and US contrast-enhanced 3D imaging employing injection of clinically-approved microbubbles.
View Article and Find Full Text PDFPropagation of electromechanical waves in excitable heart muscles follows complex spatiotemporal patterns holding the key to understanding life-threatening arrhythmias and other cardiac conditions. Accurate volumetric mapping of cardiac wave propagation is currently hampered by fast heart motion, particularly in small model organisms. Here we demonstrate that ultrafast four-dimensional imaging of cardiac mechanical wave propagation in entire beating murine heart can be accomplished by sparse optoacoustic sensing with high contrast, ∼115-µm spatial and submillisecond temporal resolution.
View Article and Find Full Text PDFImages rendered with common optoacoustic system implementations are often afflicted with distortions and poor visibility of structures, hindering reliable image interpretation and quantification of bio-chrome distribution. Among the practical limitations contributing to artifactual reconstructions are insufficient tomographic detection coverage and suboptimal illumination geometry, as well as inability to accurately account for acoustic reflections and speed of sound heterogeneities in the imaged tissues. Here we developed a convolutional neural network (CNN) approach for enhancement of optoacoustic image quality which combines training on both time-resolved signals and tomographic reconstructions.
View Article and Find Full Text PDFIEEE Trans Med Imaging
August 2021
Wide-scale adoption of optoacoustic imaging in biology and medicine critically depends on availability of affordable scanners combining ease of operation with optimal imaging performance. Here we introduce LightSpeed: a low-cost real-time volumetric handheld optoacoustic imager based on a new compact software-defined ultrasound digital acquisition platform and a pulsed laser diode. It supports the simultaneous signal acquisition from up to 192 ultrasound channels and provides a hig-bandwidth direct optical link (2x 100G Ethernet) to the host-PC for ultra-high frame rate image acquisitions.
View Article and Find Full Text PDFOptoacoustic (OA) imaging has the capacity to effectively bridge the gap between macroscopic and microscopic realms in biological imaging. High-resolution OA microscopy has so far been performed via point-by-point scanning with a focused laser beam, thus greatly restricting the achievable imaging speed and/or field of view. Herein we introduce multifocal structured illumination OA microscopy (MSIOAM) that attains real-time 3D imaging speeds.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
January 2021
Ultrasound can be delivered transcranially to ablate brain tissue, open the blood-brain barrier, or affect neural activity. Transcranial focused ultrasound in small rodents is typically done with low-frequency single-element transducers, which results in unspecific targeting and impedes the concurrent use of fast neuroimaging methods. In this article, we devised a wide-angle spherical array bidirectional interface for high-resolution parallelized optoacoustic imaging and transcranial ultrasound (POTUS) delivery in the same target regions.
View Article and Find Full Text PDFOptoacoustic image formation is conventionally based upon ultrasound time-of-flight readings from multiple detection positions. Herein, we exploit acoustic scattering to physically encode the position of optical absorbers in the acquired signals, thus reducing the amount of data required to reconstruct an image from a single waveform. This concept is experimentally tested by including a random distribution of scatterers between the sample and an ultrasound detector array.
View Article and Find Full Text PDFState-of-the-art optoacoustic tomographic imaging systems have been shown to attain three-dimensional (3D) frame rates of the order of 100 Hz. While such a high volumetric imaging speed is beyond reach for other bio-imaging modalities, it may still be insufficient to accurately monitor some faster events occurring on a millisecond scale. Increasing the 3D imaging rate is usually hampered by the limited throughput capacity of the data acquisition electronics and memory used to capture vast amounts of the generated optoacoustic (OA) data in real time.
View Article and Find Full Text PDFThe recently demonstrated control over light distribution through turbid media based on real-time three-dimensional optoacoustic feedback has offered promising prospects to interferometrically focus light within scattering objects. Nevertheless, the focusing capacity of the feedback-based approach is strongly conditioned by the number of optical modes (speckle grains) enclosed in the volume that can be resolved with the optoacoustic imaging system. In this Letter, we experimentally tested the light intensity enhancement achieved with optoacoustic feedback measurements from different sizes of absorbing microparticles.
View Article and Find Full Text PDFOptoacoustic tomography provides a unique possibility for ultra-high-speed 3-D imaging by acquiring complete volumetric datasets from interrogation of tissue by a single nanosecond-duration laser pulse. Yet, similarly to ultrasound, optoacoustics is a time-resolved imaging method, thus, fast 3-D imaging implies real-time acquisition and processing of high speed data from hundreds of detectors simultaneously, which presents significant technological challenges. Herein we present a highly efficient graphical processing unit (GPU) framework for real-time reconstruction and visualization of 3-D tomographic optoacoustic data.
View Article and Find Full Text PDFObjective: Brucella endocarditis is a rare complication of Brucella infection; however, it is the major cause of deaths in those infected with this disease. In this study, we aim to discuss the results of seven cases who underwent surgery for Brucella endocarditis in our clinic using the knowledge gathered through the literature.
Methods: We reviewed seven patients with Brucella endocarditis, who underwent surgery in our department between October 1990 and April 2007.