Publications by authors named "Ali M Yehia"

Detection of erythromycin (ERY) residues in commercial milk samples is crucial for the safety assessment. Herein, a printed circuit board was patterned as a feasible miniaturized potentiometric sensor for ERY determination in dairy samples. The proposed chip design fits to a 3.

View Article and Find Full Text PDF

Chiral high performance liquid chromatographic technique usually employs polysaccharide-based stationary phases in a normal phase mode. This frequently generates large waste of organic solvents. Using shorter columns of 50 mm length as well as a mobile phase with a high water percentage are common approaches for greening this analytical technique.

View Article and Find Full Text PDF

Nutraceuticals are promoted and marketed with the stated label of being natural as well as safe herbal products. In order to enhance their effectiveness, nutraceuticals are usually adulterated with undeclared constituents. Slimming herbs may contain sibutramine (SBT) which is an FDA-banned ingredient due to its fatal outcomes.

View Article and Find Full Text PDF

The intensive use of antibiotics in livestock practice has a negative impact on human health and increases the antibiotic resistance. In this study feasible data interpretation algorithm along with efficient extraction protocol were combined for selective analysis of three antibiotics in milk samples. Trimethoprim, sulphamethoxazole and oxytetracycline are widely used antibiotics in veterinary pharmaceuticals.

View Article and Find Full Text PDF

Flunitrazepam is one of the frequently used hypnotic drugs to incapacitate victims for sexual assault. Appropriate diagnostic tools should be available to victims regarding the growing concern about "date-rape drugs" and their adverse impact on society. Miniaturized screen-printed potentiometric sensors offer crucial point-of-care devices that alleviate this serious problem.

View Article and Find Full Text PDF

Sinus and congestion mixture of three drugs and an impurity was studied for their spectral resolution using four multivariate algorithms. The studied drugs present in extremes of low and high concentrations. Low concentration levels of phenylephrine HCl and doxylamine succinate with high concentration of paracetamol along with its official impurity was a challenging mixture for pharmaceutical analysis.

View Article and Find Full Text PDF

Multiplex ion analyzers have been introduced recently for the assay of several inorganic ions, whilst electrochemists have extensively employed screen printed sensors for pharmaceutical analyses. This work aims to develop a USB pluggable sensor with a user-friendly design for multiplex analysis of oppositely charged co-formulated organic ions. The miniaturized screen-printed electrode was developed using silver ink on paper substrate.

View Article and Find Full Text PDF

Paper-based microfluidic device was designed with wax-printing to combine potentiometric, fluorimetric and colorimetric detection zones. This newly developed trimodal paper chip has been used for on-site determination of ketamine hydrochloride (KET) as a date rape drug in beverages. The device employed polyaniline nano-dispersion as conducting polymer in ion sensing paper electrodes designed to fit USB plug connector.

View Article and Find Full Text PDF

A sensitive accurate spectrofluorimetric technique was developed to detect cefadroxil and cefradine traces in water samples simultaneously, by applying a procedure based on the formation of hydrolysis products corresponding to these compounds by sodium hydroxide (1 N NaOH) treatment. The conventional and the synchronous fluorescence spectra of these hydrolyzed products were totally overlapped making resolving of this mixture impossible. The second-derivative constant-wavelength synchronous fluorescence spectra allowed their detection simultaneously in a single scan after experimental conditions optimization, which was measured at 390 nm and 379 nm for cefadroxil and cefradine, respectively at Δλ = 30.

View Article and Find Full Text PDF

Chiral stationary phases are conveniently used for enantiomeric separation of drugs by liquid chromatography. Consumption of large volumes of hazardous solvents is considered as a common challenge for the sustainability of this technique. To this end, a columnar chromatography has been adopted using 50-mm-length stationary phases.

View Article and Find Full Text PDF

Background: Chemometrics is a discipline that allows the spectral resolution of drugs in a complicated matrix (e.g., environmental water samples) as an alternative to chromatographic methods.

View Article and Find Full Text PDF

Inclusion complexes of β-cyclodextrin with Estradiol valerate (EST) or Norethisterone acetate (NOR) have been utilized for synchronous fluorescence spectrofluorimetry. β-cyclodextrin improves fluorescence intensity as well as water solubility of the studied drugs. Samples in aqueous medium adjusted with ammonia were used in synchronous fluorescence to resolve the overlapped emission spectra.

View Article and Find Full Text PDF

Chemometrics approaches have been used in this work to trace cephalosporins in aquatic system. Principal component regression (PCR), partial least squares (PLS), multivariate curve resolution-alternating least squares (MCR-ALS), and artificial neural networks (ANN) were compared to resolve the severally overlapped spectrum of three selected cephalosporins; cefprozil, cefradine and cefadroxil. The analytical performance of chemometric methods was compared in terms of errors.

View Article and Find Full Text PDF

Cesium-gold (Cs-Au) nanoparticles are shown to be analytically advantageous for the electroanalytical sensing of dapoxetine (DPX), a serotonin reuptake inhibitor used for the treatment of premature ejaculation. The Cs-Au nanoparticles are electrically wired and supported upon mass producible, economical screen-printed electrochemical sensing platforms and are characterized electrochemically (cyclic voltammetry and electrochemical impedance spectroscopy) and physiochemically (field emission scanning electron microscopy and energy dispersive X-ray analysis). The face-centered design was applied to optimize the significant experimental factors by using square wave voltammetry.

View Article and Find Full Text PDF

A strategy for trace-level carbon-based electrochemical sensors is investigated via exploring the interesting properties of BaNbO nanofibers (NFs). Utilizing adsorptive stripping square wave voltammetry (ASSWV), an electrochemical sensing platform was developed based on BaNbO nanofibers-modified carbon paste electrode (CPE) for the sensitive detection of lornoxicam (LOR). Different techniques were used to characterize the fabricated BaNbO perovskite NFs.

View Article and Find Full Text PDF

Fluoroquinolones are popular class of antibiotics with distinct chemical functionality. Most of them are ampholytes with one chiral center. Stereogeneic center is located either in the side ring of Gatifloxacin (GFLX) or in the quinolone core of Ofloxacin (OFLX).

View Article and Find Full Text PDF

Simple, smart and sensitive normal fluorescence and stability-indicating derivative synchronous spectrofluorimetric methods have been developed and validated for the determination of gliquidone in the drug substance and drug product. Normal spectrofluorimetric method of gliquidone was established in methanol at λ excitation 225nm and λ emission 400nm in concentration range 0.2-3μg/ml with LOD equal 0.

View Article and Find Full Text PDF

In the scientific context of membrane sensors and improved experimentation, we devised an experimentally designed protocol for sensor optimization. Two-step strategy was implemented for Umeclidinium bromide (UMEC) analysis which is a novel quinuclidine-based muscarinic antagonist used for maintenance treatment of symptoms accompanied with chronic obstructive pulmonary disease. In the first place, membrane components were screened for ideal ion exchanger, ionophore and plasticizer using three categorical factors at three levels in Taguchi design.

View Article and Find Full Text PDF
Article Synopsis
  • Scientists created a special sensor using materials like graphene oxide and carbon nanotubes to measure a medicine called omeprazole (OME) very accurately.
  • The new sensor worked much better than a regular one and could detect tiny amounts of OME in solutions.
  • It was tested successfully in different situations, like in medicine and blood samples, showing it can help with checking medicine quality and health tests.
View Article and Find Full Text PDF

A generally applicable high-performance liquid chromatographic method for the qualitative and quantitative determination of pharmaceutical preparations containing phenylephrine hydrochloride, paracetamol, ephedrine hydrochloride, guaifenesin, doxylamine succinate, and dextromethorphan hydrobromide is developed. Optimization of chromatographic conditions was performed for the gradient elution using different buffer pH values, flow rates and two C18 stationary phases. The method was developed using a Kinetex® C18 column as a core-shell stationary phase with a gradient profile using buffer pH 5.

View Article and Find Full Text PDF

Aspirin (ASP) and dipyridamole (DIP) in combination is widely used in the prevention of secondary events after stroke and transient ischemic attack. Salicylic acid is a well-known impurity of ASP, and the DIP extended-release formulation may contain ester impurities originating from the reaction with tartaric acid. UV spectral data analysis of the active ingredients in the presence of their main impurities is presented using multivariate approaches.

View Article and Find Full Text PDF
Article Synopsis
  • Green chemistry is becoming super important in medicine, with lots of companies focusing on eco-friendly methods for testing drugs.
  • A new green method was created to test three medicines (phenylephrine, paracetamol, and guaifenesin) all at once using safer solvents that are better for the environment.
  • This method is fast and produces less waste, making it a great alternative for checking these drugs without harming the planet.
View Article and Find Full Text PDF

Two novel cefquinome sulfate (CFQ)-selective electrodes were performed with dibutyl sebacate as a plasticizer using a polymeric matrix of polyvinyl chloride. Sensor 1 was prepared using sodium tetraphenylborate as a cation exchanger without incorporation of ionophore, whereas 2-hydroxy propyl β-cyclodextrin was used as ionophore in sensor 2. A stable, reliable, and linear response was obtained in concentration ranges 3.

View Article and Find Full Text PDF

Spectral resolution of cefquinome sulfate (CFQ) in the presence of its degradation products was studied. Three selective, accurate and rapid spectrophotometric methods were performed for the determination of CFQ in the presence of either its hydrolytic, oxidative or photo-degradation products. The proposed ratio difference, derivative ratio and mean centering are ratio manipulating spectrophotometric methods that were satisfactorily applied for selective determination of CFQ within linear range of 5.

View Article and Find Full Text PDF

Three advanced chemmometric-assisted spectrophotometric methods namely; Concentration Residuals Augmented Classical Least Squares (CRACLS), Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) and Principal Component Analysis-Artificial Neural Networks (PCA-ANN) were developed, validated and benchmarked to PLS calibration; to resolve the severely overlapped spectra and simultaneously determine; Paracetamol (PAR), Guaifenesin (GUA) and Phenylephrine (PHE) in their ternary mixture and in presence of p-aminophenol (AP) the main degradation product and synthesis impurity of Paracetamol. The analytical performance of the proposed methods was described by percentage recoveries, root mean square error of calibration and standard error of prediction. The four multivariate calibration methods could be directly used without any preliminary separation step and successfully applied for pharmaceutical formulation analysis, showing no excipients' interference.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session59v4cq6303jotocg9rrf35ib07kdq4a6): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once