Background: The advantages of patent foramen ovale (PFO) closure as protection from a recurrence of stroke remains controversial compared to drug therapy, especially in patients over 60 years.
Hypothesis: The aim of the study is to compare recurrence of stroke in patients over 60 years old with PFO closure versus drug therapy alone.
Methods: We included 342 patients over 60 years who suffered a crytopgenic stroke, and were also accepted for a PFO closure.
: The benefits of sutureless compared to conventional aortic valve prosthesis replacement remain controversial. Supposed advantages of sutureless aortic valve replacement include shortened cross-clamp and implantation time, as well as improved overall safety and good post-operative performance. We aimed to compare the early outcomes and performance of sutureless aortic valve replacement (su-AVR) with the sutureless Perceval (Corcym, Milan, Italy) vs.
View Article and Find Full Text PDFPurpose: Perceval sutureless valves have gained popularity. Whether this implant performs superior to the traditional sutured prosthesis remains unclear. This meta- analysis compared the Perceval implants versus the sutured conventional valves for aortic valve replacement (AVR).
View Article and Find Full Text PDFSeveral studies investigated the effectiveness and the safety of different doses of pregabalin in fibromyalgia. However, the optimal protocol remains controversial. A Bayesian network meta-analysis comparing 300, 450, and 600 mg/daily of pregabalin for fibromyalgia was conducted.
View Article and Find Full Text PDFObjectives: The goal of this analysis of the Perceval aortic bioprosthesis was to investigate the ovalization/deformation of the Perceval prosthesis stent after implantation and its propensity for cusp dysfunction, fluttering, fibrosis and blockage.
Methods: Between August 2014 and May 2019, a total of 134 patients (52% female) underwent aortic valve replacement with the Perceval bioprosthesis. We reconstructed three-dimensional models of the Perceval stent using thorax computed tomography scans for 16 patients employing the software Mimics (Materialise NV, Leuven, Belgium) and analysed the ovality of the stents.
Background: Current guidelines recommend interventional closure of patent foramen ovale (PFO) in patients with cryptogenic ischemic stroke who are under 60 years of age.
Hypothesis: The hypothesis of this study was to compare follow-up results of PFO closure in patients over 60 years of age to those of patients under 60 years of age in order to determine whether the procedure is safe and effective for both age groups.
Methods: We included 293 patients who had a cryptogenic ischemic stroke and a PFO confirmed by transesophageal echocardiography (TEE) and who were scheduled for percutaneous closure of the PFO between 2014 and 2019.
Interact Cardiovasc Thorac Surg
September 2020
Continuous heart rhythm monitoring with cardiac event recorders is increasing in clinical practice and may be helpful in diagnosing a wide range of disorders and pathologies. This case study describes the case of an 80-year-old female patient with a medical history of previous cardiac surgery in which a cardiac event recorder had to be retrieved from the left main pulmonary artery.
View Article and Find Full Text PDFAnn Thorac Cardiovasc Surg
February 2021
Purpose: Deep sternal wound infection (DSWI) and mediastinitis are devastating complications after median sternotomy. Previous studies demonstrated an effective prevention of sternal wound infection (SWI) using an external sternal corset in high-risk cardiac surgery patients. The aim of this study is to assess the preventive effect of the Stern-E-Fix corset in high-risk poststernotomy female patients.
View Article and Find Full Text PDFInteract Cardiovasc Thorac Surg
November 2018
Objectives: Sutureless aortic valve prostheses are gaining popularity due to the substantial reduction in cross-clamp time. In this study, we report our observations on the cusp-fluttering phenomenon of the Perceval bioprosthesis (LivaNova, London, UK) using a combination of technical and medical perspectives.
Methods: Between August 2014 and December 2016, a total of 108 patients (69% women) with a mean age of 78 years had aortic valve replacement using the Perceval bioprosthesis (34 combined procedures).
Background: Bedside non-invasive techniques, such as radial artery tonometry, to estimate hemodynamic parameters have gained increased relevance as an attractive alternative and efficient method to measure hemodynamics in outpatient departments. For our pilot study, we sought to compare cardiac output (CO), and stroke volume (SV) estimated from a radial artery tonometry blood pressure pulse analyzer (BPPA) (DMP-Life, DAEYOMEDI Co., Gyeonggi-do, South Korea) to pulsed-wave Doppler (PWD) echocardiography derived parameters.
View Article and Find Full Text PDFObjectives: Right heart failure (RHF) after the implantation of a left ventricular assist device (LVAD) remains a dreaded postoperative complication. Using 2D speckle-tracking echocardiography, it is possible to acquire right ventricular global and regional function. The aim of our study was to assess whether speckle-tracking echocardiography values will better predict the RHF post-continuous-flow LVAD implantation.
View Article and Find Full Text PDFObjectives: Acquired von Willebrand syndrome (AvWS) is associated with postoperative bleeding complications in patients with continuous flow left ventricular assist devices (CF-LVADs). The aim of this study is to analyze the perioperative vWF profile comparing an axial pump (HMII) to a centrifugal pump (HVAD) regarding the correlation between perioperative occurrence of AvWS, early- and late-postoperative bleeding events.
Methods: From July 2013 until March 2015 blood samples of 33 patients (12 HMII/ 8 HVAD/ 13 controls) were prospectively collected at 12 different time points and analyzed for the vWF antigen (vWF:Ag), its activity (vWF:Ac) and the vWF:Ac/vWF:Ag-ratio (vWF:ratio).
Interact Cardiovasc Thorac Surg
March 2017
Objectives: In patients with a small aortic annulus, aortic valve replacement (AVR) is frequently associated with high residual pressure gradients. Supra-annular pericardial aortic prostheses are gaining popularity due to the increased effective orifice areas (EOA) and resulting lower gradients. This study reports the clinical and echocardiographic results following implantation of the new supra-annular pericardial aortic prosthesis Dokimos Plus (Labcor, Belo Horizonte, Brazil).
View Article and Find Full Text PDFObjective: Disturbances of interatrial conduction have been proposed as one of the contributing mechanisms of postoperative atrial fibrillation (AF). P-wave dispersion has been recognized as a sensitive tool for detecting interatrial conduction disturbances. Doppler myocardial imaging (DMI) has been validated as a non-invasive tool to indirectly reflect electrical atrial activation and therefore is used in this study to detect possible interatrial electromechanical disturbances after cardiac surgery.
View Article and Find Full Text PDF