Purpose: Although 3D EPI is more susceptible to motion artifacts than 2D EPI, it presents some benefits for functional MRI, including the absence of spin-history artifacts, greater potential for parallel imaging acceleration, and better functional sensitivity in high-resolution imaging. Here we present a self-navigated 3D-EPI sequence suitable for prospective motion-corrected functional MRI without additional hardware or pulses.
Methods: For each volume acquisition, the first 24 of the 52 partitions being acquired are accumulated to a new feedback block that was added to the image reconstruction pipeline.
The role of ectopic fat, insulin secretion and clearance in the preservation ofβ-cell function in black African women with obesity who typically present with hyperinsulinaemia is not clear. We aim to examine the associations between disposition index (DI, an estimate of β-cell function), insulin secretion and clearance and ectopic fat deposition. This is a cross-sectional study of 43 black South African women (age 20-35 years) with obesity (BMI 30-40 kg/m2) and without type 2 diabetes that measured the following: DI, insulin sensitivity (SI), acute insulin response (AIRg), insulin secretion rate (ISR), hepatic insulin extraction and peripheral insulin clearance (frequently sampled i.
View Article and Find Full Text PDFBackground: Repeated glycoCEST MRI measurements on the same subject should produce similar results under the same environmental and experimental conditions. However, fluctuations in the static B field, which may occur between and within measurements due to heating of the shim iron or subject motion, may alter results and affect reproducibility. Here we investigate the repeatability and reproducibility of glycoCEST measurements and examine the effectiveness of a real-time shim- and motion navigated chemical exchange saturation transfer (CEST) sequence to improve reproducibility.
View Article and Find Full Text PDFSpectral editing allows direct measurement of low-concentration metabolites, such as GABA, glutathione (GSH) and lactate (Lac), relevant for understanding brain (patho)physiology. The most widely used spectral editing technique is MEGA-PRESS, which has been diversely implemented across research sites and vendors, resulting in variations in the final resolved edited signal. In this paper, we describe an effort to develop a new universal MEGA-PRESS sequence with HERMES functionality for the major MR vendor platforms with standardized RF pulse shapes, durations, amplitudes and timings.
View Article and Find Full Text PDFPurpose: CEST MRI allows for indirect detection of molecules with exchangeable protons, measured as a reduction in water signal because of continuous transfer of saturated protons. CEST requires saturation pulses on the order of a second, as well as repeated acquisitions at different offset frequencies. The resulting extended scan time makes CEST susceptible to subject motion, which introduces field inhomogeneity, shifting offset frequencies and causing distortions in CEST spectra that resemble true CEST effects.
View Article and Find Full Text PDFBackground: The pathogenesis of type 2 diabetes (T2D) in black African women is complex and differs from that in their white counterparts. However, earlier studies have been cross-sectional and provide little insight into the causal pathways. Exercise training is consistently used as a model to examine the mechanisms underlying insulin resistance and risk for T2D.
View Article and Find Full Text PDFBackground And Purpose: Fractional anisotropy in the frontal white matter, corpus callosum, and internal capsule is abnormal in human immunodeficiency virus-positive (HIV+) adults. We describe the distribution and nature of white matter abnormalities in a cohort of children who started antiretroviral therapy within the first year of life and the benefit of early treatment by using DTI measures (fractional anisotropy and mean, axial, and radial diffusion).
Materials And Methods: DTI was performed on children in a neurodevelopmental substudy from the Children with HIV Early Antiretroviral trial.
Diffusion tensor imaging (DTI) is susceptible to several artifacts due to eddy currents, echo planar imaging (EPI) distortion and subject motion. While several techniques correct for individual distortion effects, no optimal combination of DTI acquisition and processing has been determined. Here, the effects of several motion correction techniques are investigated while also correcting for EPI distortion: prospective correction, using navigation; retrospective correction, using two different popular packages (FSL and TORTOISE); and the combination of both methods.
View Article and Find Full Text PDFObjective: Measuring the pure form of GABA has become increasingly important because of its association with behaviour and certain pathologies. The aim of this study was to assess the reproducibility of GABA measurements using a shim and motion navigated MEGA-SPECIAL sequence with LCModel, jMRUI and GANNET software.
Materials And Methods: Motion and shim navigated MEGA-SPECIAL scans were acquired in 20 healthy subjects.
Mescher-Garwood (MEGA) editing with spin echo full intensity acquired localization (MEGA-SPECIAL, MSpc) is a technique to acquire γ-aminobutyric acid (GABA) without macromolecule (MM) contamination at a TE of 68 ms. However, due to the requirement of multiple shot-localization, it is often susceptible to subject motion and B0 inhomogeneity. A method is presented for real-time shim and motion correction (ShMoCo) using volumetric navigators to correct for motion and motion-related B0 inhomogeneity during MSpc acquisition.
View Article and Find Full Text PDFDiffusion tensor imaging (DTI) requires a set of diffusion weighted measurements in order to acquire enough information to characterize local structure. The MRI scanner automatically performs a shimming process by acquiring a field map before the start of a DTI scan. Changes in B0, which can occur throughout the DTI acquisition due to several factors (including heating of the iron shim coils or subject motion), cause significant signal distortions that result in warped diffusion tensor (DT) parameter estimates.
View Article and Find Full Text PDFFetal alcohol spectrum disorders (FASD) are characterized by a range of neurodevelopmental deficits that result from prenatal exposure to alcohol. These can include cognitive, behavioural, and neurological impairment, as well as structural and functional brain damage. Eyeblink conditioning (EBC) is among the most sensitive endpoints affected in FASD.
View Article and Find Full Text PDFPrenatal alcohol exposure (PAE) is known to have severe, long-term consequences for brain and behavioral development already detectable in infancy and childhood. Resulting features of fetal alcohol spectrum disorders include cognitive and behavioral effects, as well as facial anomalies and growth deficits. Diffusion tensor imaging (DTI) and tractography were used to analyze white matter (WM) development in 11 newborns (age since conception <45 weeks) whose mothers were recruited during pregnancy.
View Article and Find Full Text PDFPurpose: To evaluate the patterns of head motion in scans of young children and to examine the influence of corrective techniques, both qualitatively and quantitatively. We investigate changes that both retrospective (with and without diffusion table reorientation) and prospective (implemented with a short navigator sequence) motion correction induce in the resulting diffusion tensor measures.
Materials And Methods: Eighteen pediatric subjects (aged 5-6 years) were scanned using 1) a twice-refocused, 2D diffusion pulse sequence, 2) a prospectively motion-corrected, navigated diffusion sequence with reacquisition of a maximum of five corrupted diffusion volumes, and 3) a T1 -weighted structural image.
Purpose. To evaluate whether 3T clinical MRI with a small-animal coil and gradient-echo (GE) sequence could be used to characterize long-term left ventricular remodelling (LVR) following nonreperfused myocardial infarction (MI) using semi-automatic segmentation software (SASS) in a rat model. Materials and Methods.
View Article and Find Full Text PDFProspective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel technique using a three-dimensional-echo planar imaging navigator, of which the contrast is independent of the b-value, to perform prospective motion correction in diffusion weighted images, without having to reacquire volumes during which motion occurred, unless motion exceeded some preset thresholds.
View Article and Find Full Text PDF