Publications by authors named "Alfredo Garcia Arieta"

In the European Union, bioequivalence (BE) for narrow therapeutic index (NTI) drugs is currently demonstrated when the 90% confidence interval for the ratio of the population geometric means of the test and reference products for AUC, and in some cases for Cmax, falls within the acceptance range of 90.00% to 111.11%.

View Article and Find Full Text PDF

The characterization of the time course of ibuprofen enantiomers can be useful in the selection of the most sensitive analyte in bioequivalence studies. Physiologically based pharmacokinetic (PBPK) modelling and simulation represents the most efficient methodology to virtually assess bioequivalence outcomes. In this work, we aim to develop and verify a PBPK model for ibuprofen enantiomers administered as a racemic mixture with different immediate release dosage forms to anticipate bioequivalence outcomes based on different particle size distributions.

View Article and Find Full Text PDF

Bioequivalence (BE) studies are considered the standard for demonstrating that the performance of a generic drug product in the human body is sufficiently similar to that of its comparator product. The objective of this article is to describe the recommendations from participating Bioequivalence Working Group for Generics (BEWGG) members of the International Pharmaceutical Regulators Programme (IPRP) regarding the conduct and acceptance criteria for BE studies of immediate release solid oral dosage forms. A survey was conducted among BEWGG members regarding their BE recommendations and requirements related to study subjects, study design, sample size, single or multiple dose administration, study conditions (fasting or fed), analyte to be measured, selection of product strength, drug content, handling of endogenous substances, BE acceptance criteria, and additional design aspects.

View Article and Find Full Text PDF

The development of second-entry topical products is hampered by several factors. The excipient composition should be similar to the reference product because excipients may also contribute to efficacy. Conventional pharmacokinetic bioequivalence studies were not considered acceptable because drug concentrations are measured downstream after the site of action.

View Article and Find Full Text PDF

(1) Background: this article investigates which PK metrics in a single-dose study (concentration at the end of posology interval, C, partial areas under the curve, pAUCs, or half-value duration, HVD) are more sensitive and less variable for predicting the failure of a prolonged-release product at steady-state that was the bioequivalent for C, AUC and AUC, in the single-dose study; (2) Methods: a cross-over study was performed in 36 subjects receiving desvenlafaxine 100 mg prolonged-release tablets. Conventional (C, AUC and AUC) and additional (C, pAUCs and HVD) PK metrics were considered after single-dose conditions. Predicted PK metrics at steady state (AUC, C, and C) were derived using a population PK model approach; (3) Results: the existing differences in the shape of the concentration-time curves precluded to show equivalence for C in the simulated study at steady state.

View Article and Find Full Text PDF

Some years ago, excipients were considered inert substances irrelevant in the absorption process. However, years of study have demonstrated that this belief is not always true. In this study, the reasons for a bioequivalence failure between two formulations of silodosin are investigated.

View Article and Find Full Text PDF

Bioequivalence (BE) of products containing narrow therapeutic index (NTI) drugs in the European Union is currently established by demonstrating that the 90% confidence interval for the ratio of the population geometric means of the test compared to the reference product’s AUC, and in certain cases Cmax, is included within the tighter acceptance range of 90.00−111.11%.

View Article and Find Full Text PDF

Atorvastatin is the most prescribed 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitor used to lower cardiovascular risk and constitutes one of the best-selling drugs world-wide. Several physiologically based pharmacokinetic (PBPK) models have been developed to assess its non-straightforward pharmacokinetics (PK) as well as that of its metabolites and have been only applied to assess drug-drug interactions (DDI). Here we present a full PBPK model for atorvastatin and its metabolites able to predict within a 2-fold error their PK after the administration of a solid oral dosage form containing the calcium salt of atorvastatin in single and multiple dosing schedules at 20, 40, and 80 mg and 10 mg dose levels, respectively.

View Article and Find Full Text PDF

The safety and efficacy of a generic product are partly based on demonstrating bioequivalence to the innovator product; however, when the innovator product is no longer available as a comparator product, a survey conducted within the Bioequivalence Working Group for Generics (BEWGG) of the International Pharmaceutical Regulators Programme (IPRP) indicated that the criteria for selecting an alternative comparator product varies. For most members of the BEWGG, an existing marketed generic that was approved based on a comparison with the locally registered innovator product can be used, contingent on criteria that ranges from allowing any generic to be used, to allowing only specific criteria-defined generics to be used. Notwithstanding the acceptability of a generic as an alternative comparator, it is not always the preferred comparator for several jurisdictions.

View Article and Find Full Text PDF

This article describes an overview of waivers of in vivo bioequivalence studies for additional strengths in the context of the registration of modified release generic products and is a follow-up to the recent publication for the immediate release solid oral dosage forms. The current paper is based on a survey among the participating members of the Bioequivalence Working Group for Generics (BEWGG) of the International Pharmaceutical Regulators Program (IPRP) regarding this topic. Most jurisdictions consider the extrapolation of bioequivalence results obtained with one (most sensitive) strength of a product series as less straightforward for modified release products than for immediate release products.

View Article and Find Full Text PDF

The current regulatory criterion for bioequivalence of narrow therapeutic index (NTI) drugs in the European Union requires that the 90% confidence interval for the ratio of the population geometric means of the test product compared with the reference for area under the plasma concentration-time curve (AUC), and in certain cases maximum plasma drug concentration (C ), to be included within the tighter acceptance range of 90.00-111.11%.

View Article and Find Full Text PDF

Background And Objectives: The most widely used method to compare dissolution profiles is the similarity factor f. When this method is not applicable, the confidence interval of f using bootstrap methodology has been recommended instead. As neither details of the estimator nor the types of confidence intervals are described in the guidelines, the suitability of five estimators and fourteen types of confidence intervals were investigated in this study by simulation.

View Article and Find Full Text PDF

Atorvastatin (ATS) is the gold-standard treatment worldwide for the management of hypercholesterolemia and prevention of cardiovascular diseases associated with dyslipidemia. Physiologically based pharmacokinetic (PBPK) models have been positioned as a valuable tool for the characterization of complex pharmacokinetic (PK) processes and its extrapolation in special sub-groups of the population, leading to regulatory recognition. Several PBPK models of ATS have been published in the recent years, addressing different aspects of the PK properties of ATS.

View Article and Find Full Text PDF

Albendazole is a benzimidazole carbamate drug with anthelmintic and antiprotozoal activity against intestinal and tissue parasites. It has been described that the administration with meals increases albendazole absorption. Our aim was to compare the systemic exposure in healthy volunteers of two albendazole formulations after a single oral dose under fed conditions and to evaluate the effect of breakfast composition on albendazole and albendazole sulfoxide bioavailability.

View Article and Find Full Text PDF

The purpose of this study was to predict in vivo performance of three oral products of Etoricoxib ( as reference and two generic formulations in development) by conducting in vivo predictive dissolution with GIS (Gastro Intestinal Simulator) and computational analysis. Those predictions were compared with the results from previous bioequivalence (BE) human studies. Product dissolution studies were performed using a computer-controlled multicompartmental dissolution device (GIS) equipped with three dissolution chambers, representing stomach, duodenum, and jejunum, with integrated transit times and secretion rates.

View Article and Find Full Text PDF
Article Synopsis
  • The text discusses the criteria for waiving in vivo bioequivalence studies for various oral and injectable dosage forms based on the Biopharmaceutics Classifications System (BCS) and highlights that biowaivers can be accepted under certain conditions.
  • It summarizes the findings from the Bioequivalence Working Group for Generics (BEWGG) regarding the requirements for oral solutions, suspensions, soft gelatin capsules, and various types of injectable products.
  • The paper notes a trend towards regulatory convergence, especially for less complex dosage forms, although significant differences in guidelines and acceptability of changes among jurisdictions still exist.
View Article and Find Full Text PDF

Inter- and intra-batch variability of the quality attributes contribute to the uncertainty for demonstrating equivalent microstructure of post-approval changes and generic/hybrids of semisolid topical products. Selecting a representative sample size to describe accurately the in vitro properties of semisolids and to reach enough statistical power to demonstrate similarity between two semisolid topical products is currently challenging. The objective of this work is to establish the number of batches and units per batch to be compared based on different inter-batch and intra-batch variability to demonstrate equivalence in the physical characteristics of the products that ensure a similar microstructure of the semisolid.

View Article and Find Full Text PDF

The main objective of this investigation was to develop an in vitroin vivo correlation (IVIVC) for immediate release candesartan cilexetil formulations by designing an in vitro dissolution test to be used as development tool. The IVIVC could be used to reduce failures in future bioequivalence studies. Data from two bioequivalence studies were scaled and combined to obtain the dataset for the IVIVC.

View Article and Find Full Text PDF

According to the Ibuprofen Product-Specific Bioequivalence Guidance of the European Medicines Agency, achiral bioanalytical methods are considered acceptable for demonstration of bioequivalence of ibuprofen-containing products. The aim of this investigation is to compare the bioequivalence outcomes obtained with individual R and S ibuprofen enantiomers and the sum of both enantiomers from bioequivalence studies in which new intravenous ibuprofen products were compared with oral ibuprofen products. Bioequivalence was assessed for S and R enantiomers of ibuprofen and the sum of both enantiomers, which was calculated to represent the results that would have been obtained with an achiral assay.

View Article and Find Full Text PDF

The purpose of this work is to explore the predictive ability of the biopharmaceutics classification system (BCS) biowaiver based on the dissolution methods for two pravastatin test products, where one of them showed bioequivalence (BE) while the other test failed (non-bioequivalence, or NBE), and to explore the reasons for the BE failure. Experimental solubility and permeability data confirmed that pravastatin is a BCS class III compound. The permeability experiments confirmed that the NBE formulation significantly increased pravastatin permeability, and could explain its higher absorption rate and higher C.

View Article and Find Full Text PDF

The bioequivalence of a new ibuprofen 600-mg film-coated tablet obtained by roller compaction was studied in a crossover study with 22 healthy volunteers. Bioequivalence was analyzed based on (a) the S-enantiomer, (b) the R-enantiomer, and (c) the sum of both enantiomers (representing the results of an achiral assay). The bioequivalence conclusion for ibuprofen products should be based not only on AUC and Cmax but also on tmax since tmax is related to the onset of action.

View Article and Find Full Text PDF

Demonstration of similar microstructure is essential for demonstrating the equivalence of generic topical products since the microstructure of semisolids may affect the drug release. The objective of this study was to compare the microstructure-defining physical parameters of different batches of a reference ointment containing calcipotriol and betamethasone (Daivobet 50 µg/0.5 mg/g) in order to define the acceptance range that allows concluding equivalence between these batches.

View Article and Find Full Text PDF