Publications by authors named "Alfred Albano"

Background: Atrial fibrillation (AF) increases stroke and mortality in patients with hypertrophic cardiomyopathy (HCM). Cardiac MRI (CMR) is increasingly used to detect late gadolinium enhancement (LGE) as a reliable indicator of left ventricular fibrosis, a potential predisposing factor of AF. Our research explored the correlation between left ventricular LGE and AF prevalence in HCM.

View Article and Find Full Text PDF

Background: The CONVERGE trial demonstrated that hybrid epicardial and endocardial ablation was more effective than catheter ablation for the treatment of persistent atrial fibrillation (AF) at 1 year. Long-term real-world outcome data are scarce.

Objective: We described a single-center experience by evaluating the long-term effectiveness and safety of hybrid epicardial-endocardial ablation.

View Article and Find Full Text PDF

Background: Detection of atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS) is challenging due to its paroxysmal nature. We sought to assess AF detection with an insertable cardiac monitor (ICM) and to perform cost analysis for various AF monitoring strategies post-ESUS We applied this cost analysis modeling to recently published Stroke AF and Per Diem trials.

Methods: Retrospective chart review was performed in consecutive hospitalized patients with ESUS who had ICM placed prior to discharge.

View Article and Find Full Text PDF

Background: The sudden death (SD) risk stratification algorithm in hypertrophic cardiomyopathy (HCM) has evolved, underscored recently by novel cardiac magnetic resonance (CMR)-based risk markers (left ventricular apical aneurysm, extensive late gadolinium enhancement, and end-stage disease with systolic dysfunction) incorporated into the 2020 American Heart Association (AHA)/American College of Cardiology (ACC) HCM guidelines.

Objective: The purpose of this study was to assess the specific impact of newer, predominantly CMR-based risk markers in a large multicenter HCM population that underwent primary prevention implantable cardioverter-defibrillator (ICD) implants.

Methods: Longitudinal study of 1149 consecutive HCM patients from 6 North American and European HCM centers prospectively judged to be at high SD risk based on ≥1 AHA/ACC individual risk markers and prophylactically implanted with an ICD was performed.

View Article and Find Full Text PDF

Background: It is common practice to observe patients during an overnight stay (ONS) following a catheter ablation procedure for the treatment of atrial fibrillation (AF).

Objectives: To investigate the safety and economic impact of a same-day discharge (SDD) protocol after cryoballoon ablation for treatment of AF in high-volume, geographically diverse US hospitals.

Methods: We retrospectively reviewed 2374 consecutive patients (1119 SDD and 1180 ONS) who underwent cryoballoon ablation for AF at three US centers.

View Article and Find Full Text PDF

Objectives: We aimed to estimate the prevalence and correlates of QT interval prolongation in rural Uganda.

Background: Major electrocardiographic abnormalities, including prolonged QT interval, have been shown to be independently predictive of adverse cardiovascular events among Western populations. Cardiovascular diseases are on the rise in sub-Saharan Africa with poorly characterized context-specific risk factors.

View Article and Find Full Text PDF

Objectives: Atrial fibrillation (AF) is a major risk factor for stroke, which is the leading cause of cardiovascular mortality in sub-Saharan Africa. However, there is limited population-based epidemiological data on AF in sub-Saharan Africa. We sought to estimate the prevalence and correlates of AF in rural Uganda.

View Article and Find Full Text PDF

Background: The incidence of sudden arrhythmic death is markedly increased in diabetics.

Objective: The purpose of this study was to develop a mouse model for postmyocardial infarction (post-MI) ventricular tachycardia (VT) in the diabetic heart and determine the mechanism of an antiarrhythmic effect of statins.

Methods: ECG transmitters were implanted in wild-type (WT), placebo, and pravastatin-treated type I diabetic Akita mice.

View Article and Find Full Text PDF

Although a reduction in the high-frequency (HF) component of heart rate variability (HRV) is a major complication of diabetes and a risk factor for sudden death, its relationship to ventricular tachycardia (VT) is unknown. We developed a mouse model for the study of VT and its relationship to changes in HRV in the Akita type 1 diabetic mouse. Programmed ventricular stimulation of anesthetized mice demonstrated that Akita mice were more inducible for VT compared with wild-type mice: 78.

View Article and Find Full Text PDF

Serial echocardiographic follow-up of patients with a bicuspid aortic valve (BAV), in addition to providing assessment of valve dysfunction, can help identify those at risk of aortic complications. However, currently there is no standardized echocardiographic method for measuring the ascending aorta. We examined the echocardiograms of 45 patients with a BAV and 45 matched controls to understand the effects of the measurement location (1, 2, and 3 cm above the sinotubular junction) and the point in the cardiac cycle (end-diastole, mid-systole, and end-systole) at which the ascending aortic measurements are made.

View Article and Find Full Text PDF

This new training method is based on developing a sound understanding of the sequence in which electrical excitation spreads through both the normal and the infarcted myocardium. The student is made aware of the cardiac electrical performance through a series of 3-dimensional pictures during the excitation process. The electrocardiogram 3D Heart 3-dimensional program contains a variety of different activation simulations.

View Article and Find Full Text PDF

A comparison was performed between the points measured using the Selvester QRS scoring system in 60 electrocardiograms (ECGs) displayed in both a standard format as well as a 4-fold magnified (quad-plot) format. Fifty criteria (a maximum possibility of 31 points) were evaluated in each ECG. The data indicate that in 50% of the ECGs, an identical number of points were measured.

View Article and Find Full Text PDF

Although the Selvester Scoring System for estimating the size of myocardial infarction from the standard 12-lead electrocardiogram (ECG) has potential clinical value, it has found limited application because of the difficulties in making precise and reproducible measurements. The objective of this study was to develop software to automate the Selvester Scoring System, thus allowing wider application of the technique. The study was carried out using a training set consisting of ECG data recorded from 705 individuals with and without previous myocardial infarction.

View Article and Find Full Text PDF

Background: Use of intravenous fibrinolytic agents and percutaneous coronary interventions produce the greatest benefit when they are implemented in the first 2 hours after symptom onset. Further delays in the time to treatment typically lead to reduced benefits and poorer outcomes.

Methods: Cabarrus County Emergency Medical Service personnel complete an acute myocardial infarction case report form and assess a 12-lead electrocardiogram (ECG) to determine if ST elevation of at least 1 mV in at least 2 contiguous leads is present and then to transmit the ECG wirelessly to the emergency department (ED).

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionov81rh1o7cepbeprf09t7dbo4e6vt4pe): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once