Since its invention over a hundred years ago, histological analysis using coloured dye staining remains the gold standard for histopathology. While these stains provide critical information for a variety of diagnostic purposes, they offer limited two-dimensional histological information. Extending classical histological analysis to three dimensions requires novel imaging approaches such as multiphoton microscopy.
View Article and Find Full Text PDFHuman vocal folds (VFs) possess a unique anatomical structure and mechanical properties for human communication. However, VFs are prone to scarring as a consequence of overuse, injury, disease or surgery. Accumulation of scar tissue on VFs inhibits proper phonation and leads to partial or complete loss of voice, with significant consequences for the patient's quality of life.
View Article and Find Full Text PDFDespite global efforts aimed at its elimination, malaria is still a significant health concern in many countries across the world. The disease is caused by blood-borne parasites, Plasmodium species, and is transmitted by female Anopheles mosquitoes and presents with generic febrile symptoms that are challenging to diagnose clinically. To adequately tackle this issue, an effective detection method is required for screening potential malaria patients for infection.
View Article and Find Full Text PDFLight sheet microscopy techniques have expanded with designs to address many new applications. Due to rapid advancements in computing power, camera/detector technologies, and tissue clearing techniques, light sheet methods are becoming increasingly popular for biomedical imaging applications at the cellular and tissue levels. Light sheet imaging modalities couple rapid imaging rates, low-levels of phototoxicity, and excellent signal to noise ratios, contributing to their popularity for experimental biology.
View Article and Find Full Text PDFA novel, easy to prototype hydrocarbon gel-based active valve was developed for use in centrifugal microfluidic devices. The valve has been demonstrated to restrict flow by an additional 1000 revolutions per minute (RPM) when compared to a passive capillary valve of the same size located at the same radius. Opening of the valve is accomplished in a contactless manner using a stream of focused compressed air.
View Article and Find Full Text PDFAn image segmentation based method was developed to perform volumetric measurements of liquid aliquots in centrifugal microfluidic platforms in motion. The method was designed to be as automated as possible to allow its applicability to the large variety of available design features that tend to be included on such platforms. Experiments have indicated a relative standard deviation (RSD) of 0.
View Article and Find Full Text PDFIn this technical note, a liquid-liquid extraction technique was performed using pneumatic liquid recirculation on a centrifugal microfluidic device. Non-contact pneumatic pumping enabled a multi-cycle liquid-liquid extraction process using aqueous iodine in a potassium iodide solution and hexadecane while requiring a minimal amount of space on the device. The extraction process was completely automated on the device following sample introduction and required only 50 s for each extraction cycle.
View Article and Find Full Text PDF