Publications by authors named "Alexandre Urzhumtsev"

Three-dimensional cryo electron microscopy reconstructions are obtained by extracting information from a large number of projections of the object. These projections correspond to different 'views' or 'orientations', directions in which these projections show the reconstructed object. Uneven distribution of these views and the presence of dominating preferred orientations may distort the reconstructed spatial images.

View Article and Find Full Text PDF

A flat mask-based model is almost universally used in macromolecular crystallography to account for disordered (bulk) solvent. This model assumes any voxel of the crystal unit cell that is not occupied by the atomic model is occupied by the solvent. The properties of this solvent are assumed to be exactly the same across the whole volume of the unit cell.

View Article and Find Full Text PDF

The bulk solvent is a major component of biomacromolecular crystals that contributes significantly to the observed diffraction intensities. Accurate modelling of the bulk solvent has been recognized as important for many crystallographic calculations. Owing to its simplicity and modelling power, the flat (mask-based) bulk-solvent model is used by most modern crystallographic software packages to account for disordered solvent.

View Article and Find Full Text PDF

In X-ray crystallography and cryo-EM, experimental maps can be heterogeneous, showing different level of details in different regions. In this work we interpret heterogeneity in terms of two parameters, assigned individually for each atom, combining the conventional atomic displacement parameter with the resolution of the atomic image in the map. We propose a local real-space procedure to estimate the values of these heterogeneity parameters, assuming that a fragment of the density map and atomic positions are given.

View Article and Find Full Text PDF

Diffraction intensities from a crystallographic experiment include contributions from the entire unit cell of the crystal: the macromolecule, the solvent around it and eventually other compounds. These contributions cannot typically be well described by an atomic model alone, i.e.

View Article and Find Full Text PDF

This work addresses the problem of the calculation of limited-resolution maps from an atomic model in cryo-electron microscopy and in X-ray and neutron crystallography, including cases where the resolution varies from one molecular region to another. Such maps are necessary in real-space refinement for comparison with the experimental maps. For an appropriate numeric comparison, the calculated maps should reproduce not only the structural features contained in the experimental maps but also the principal map distortions.

View Article and Find Full Text PDF

Refinement of macromolecular atomic models versus experimental maps in crystallography and cryo-electron microscopy is a critical step in structure solution. For an appropriate comparison, model maps should mimic the imperfections in the experimental maps, mainly atomic disorder and limited resolution, which are often inhomogeneous over the molecular region. In the suggested method, these model maps are calculated as the sum of atomic contributions expressed through a specifically designed function describing a solitary spherical wave.

View Article and Find Full Text PDF

High-quality atomic models providing structural information are the results of their refinement versus diffraction data (reciprocal-space refinement), or versus experimental or experimentally based maps (real-space refinement). A proper real-space refinement can be achieved by comparing such a map with a map calculated from the atomic model. Similar to density distributions, the maps of a limited and even inhomogeneous resolution can also be calculated as sums of terms, known as atomic images, which are three-dimensional peaky functions surrounded by Fourier ripples.

View Article and Find Full Text PDF

A fundamental prerequisite for implementing new procedures of atomic model refinement against neutron diffraction data is the efficient handling of hydrogen atoms. The riding hydrogen model, which constrains hydrogen atom parameters to those of the non-hydrogen atoms, is a plausible parameterization for refinements. This work describes the implementation of the riding hydrogen model in the Computational Crystallography Toolbox and in Phenix.

View Article and Find Full Text PDF

Three-dimensional structure models refined using low-resolution data from crystallographic or electron cryo-microscopy experiments can benefit from high-quality restraints derived from quantum-chemical methods. However, nonperiodic atom-centered quantum-chemistry codes do not inherently account for nearest-neighbor interactions of crystallographic symmetry-related copies in a satisfactory way. Here, these nearest-neighbor effects have been included in the model by expanding to a super-cell and then truncating the super-cell to only include residues from neighboring cells that are interacting with the asymmetric unit.

View Article and Find Full Text PDF

Diffraction (X-ray, neutron and electron) and electron cryo-microscopy are powerful methods to determine three-dimensional macromolecular structures, which are required to understand biological processes and to develop new therapeutics against diseases. The overall structure-solution workflow is similar for these techniques, but nuances exist because the properties of the reduced experimental data are different. Software tools for structure determination should therefore be tailored for each method.

View Article and Find Full Text PDF

A new type of mask-selection criterion is suggested for mask-based phasing. In this phasing approach, a large number of connected molecular masks are randomly generated. Structure-factor phases corresponding to a trial mask are accepted as an admissible solution of the phase problem if the mask satisfies some specified selection rules that are key to success.

View Article and Find Full Text PDF

Recent advances in the field of electron cryomicroscopy (cryo-EM) have resulted in a rapidly increasing number of atomic models of biomacromolecules that have been solved using this technique and deposited in the Protein Data Bank and the Electron Microscopy Data Bank. Similar to macromolecular crystallography, validation tools for these models and maps are required. While some of these validation tools may be borrowed from crystallography, new methods specifically designed for cryo-EM validation are required.

View Article and Find Full Text PDF

TLS modelling was developed by Schomaker and Trueblood to describe atomic displacement parameters through concerted (rigid-body) harmonic motions of an atomic group [Schomaker & Trueblood (1968), Acta Cryst. B24, 63-76]. The results of a TLS refinement are T, L and S matrices that provide individual anisotropic atomic displacement parameters (ADPs) for all atoms belonging to the group.

View Article and Find Full Text PDF

This article describes the implementation of real-space refinement in the phenix.real_space_refine program from the PHENIX suite. The use of a simplified refinement target function enables very fast calculation, which in turn makes it possible to identify optimal data-restraint weights as part of routine refinements with little runtime cost.

View Article and Find Full Text PDF

Aminoglycosides are chemically diverse, broad-spectrum antibiotics that target functional centers within the bacterial ribosome to impact all four principle stages (initiation, elongation, termination, and recycling) of the translation mechanism. The propensity of aminoglycosides to induce miscoding errors that suppress the termination of protein synthesis supports their potential as therapeutic interventions in human diseases associated with premature termination codons (PTCs). However, the sites of interaction of aminoglycosides with the eukaryotic ribosome and their modes of action in eukaryotic translation remain largely unexplored.

View Article and Find Full Text PDF

After gradually moving away from preparation methods prone to artefacts such as plastic embedding and negative staining for cell sections and single particles, the field of cryo electron microscopy (cryo-EM) is now heading off at unprecedented speed towards high-resolution analysis of biological objects of various sizes. This 'revolution in resolution' is happening largely thanks to new developments of new-generation cameras used for recording the images in the cryo electron microscope which have much increased sensitivity being based on complementary metal oxide semiconductor devices. Combined with advanced image processing and 3D reconstruction, the cryo-EM analysis of nucleoprotein complexes can provide unprecedented insights at molecular and atomic levels and address regulatory mechanisms in the cell.

View Article and Find Full Text PDF

Researcher feedback has indicated that in Urzhumtsev et al. [(2015) Acta Cryst. D71, 1668-1683] clarification of key parts of the algorithm for interpretation of TLS matrices in terms of elemental atomic motions and corresponding ensembles of atomic models is required.

View Article and Find Full Text PDF

A Monte Carlo-type approach for low- and medium-resolution phasing of single-particle diffraction data is suggested. Firstly, the single-particle phase problem is substituted with the phase problem for an imaginary crystal. A unit cell of this crystal contains a single isolated particle surrounded by a large volume of bulk solvent.

View Article and Find Full Text PDF

Improvements in structural biology methods, in particular crystallography and cryo-electron microscopy, have created an increased demand for the refinement of atomic models against low-resolution experimental data. One way to compensate for the lack of high-resolution experimental data is to use information about model geometry that can be utilized in refinement in the form of stereochemical restraints or constraints. Here, the definition and calculation of the restraints that can be imposed on planar atomic groups, in particular the angle between such groups, are described.

View Article and Find Full Text PDF

The translation-libration-screw model first introduced by Cruickshank, Schomaker and Trueblood describes the concerted motions of atomic groups. Using TLS models can improve the agreement between calculated and experimental diffraction data. Because the T, L and S matrices describe a combination of atomic vibrations and librations, TLS models can also potentially shed light on molecular mechanisms involving correlated motions.

View Article and Find Full Text PDF

Identifying the intramolecular motions of proteins and nucleic acids is a major challenge in macromolecular X-ray crystallography. Because Bragg diffraction describes the average positional distribution of crystalline atoms with imperfect precision, the resulting electron density can be compatible with multiple models of motion. Diffuse X-ray scattering can reduce this degeneracy by reporting on correlated atomic displacements.

View Article and Find Full Text PDF

Crystallographic molecular replacement method is the key tool to define an atomic structure of nucleic acids. Frequently nucleic acids are packed forming continuous helices in the crystal. This arrangement of individual molecules in "infinite" pseudo helical structures in crystal may be the reason why the molecular replacement fails to find a unique position of the search atomic model as the method requires.

View Article and Find Full Text PDF

A method is presented that modifies a 2mFobs - DFmodel σA-weighted map such that the resulting map can strengthen a weak signal, if present, and can reduce model bias and noise. The method consists of first randomizing the starting map and filling in missing reflections using multiple methods. This is followed by restricting the map to regions with convincing density and the application of sharpening.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessiono57o84cpdgvmfpj48q0p81orvkfcl3o4): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once