Ventricular fibrillation (VF)-induced cardiac arrest frequently complicates ST-segment elevation myocardial infarction (STEMI). Although larger infarct sizes (IS) correlate with a higher risk of VF, the influence of VF itself on IS has remained poorly investigated. To address this knowledge gap, we analyzed the effect of VF on IS in patients and two experimental models.
View Article and Find Full Text PDFBackground: We hypothesized that the lack of benefit of setting a low versus a high PEEP in patients with ARDS may be due in part to differences in the dynamic behavior of the expiratory valve in ventilators. We tested this hypothesis by conducting a bench comparison of the dynamic behavior of expiratory valves on ICU ventilators currently in use.
Methods: We attached 7 ICU ventilators (C5, C6, Carescape, PB980, ServoU, V500, and V680) to the ASL 5000 lung model (passive condition with compliance 20 mL/cm HO and resistance 5 cm HO/L/s) and set in volume controlled mode (tidal volume 0.