Publications by authors named "Alexandre Houdouin"

Article Synopsis
  • There is currently one clinically approved high-intensity focused ultrasound device for transcranial brain surgery that uses a multielement phased array to correct phase distortions caused by the skull.
  • The study assesses the performance of this device's phase correction methods against a full-wave simulation and an invasive hydrophone-based correction for 5 skulls and 2 targets per skull.
  • Results show that both the clinical software and full-wave simulation achieve similar pressure restoration metrics, but performance declines for off-center targets and when the incident angles of the ultrasound beam exceed 20°.
View Article and Find Full Text PDF

Clinicians have long been interested in functional brain monitoring, as reversible functional losses often precedes observable irreversible structural insults. By characterizing neonatal functional cerebral networks, resting-state functional connectivity is envisioned to provide early markers of cognitive impairments. Here we present a pioneering bedside deep brain resting-state functional connectivity imaging at 250-μm resolution on human neonates using functional ultrasound.

View Article and Find Full Text PDF

Aims: Pulsed cavitational ultrasound therapy (thombotripsy) allows the accurate fractionation of a distant thrombus. We aimed to evaluate the efficacy and safety of non-invasive thrombotripsy using a robotic assisted and high frequency ultrasound approach to recanalize proximal deep venous thrombosis (DVT) in a swine model.

Methods: Occlusive thrombosis was obtained with a dual jugular and femoral endoveinous approach.

View Article and Find Full Text PDF

The phase correction necessary for transcranial ultrasound therapy requires numerical simulation to noninvasively assess the phase shift induced by the skull bone. Ideally, the numerical simulations need to be fast enough for clinical implementation in a brain therapy protocol and to provide accurate estimation of the phase shift to optimize the refocusing through the skull. In this article, we experimentally performed transcranial ultrasound focusing at 900 kHz on N = 5 human skulls.

View Article and Find Full Text PDF

For successful brain therapy, transcranial focused ultrasound must compensate for the time shifts induced locally by the skull. The patient-specific phase profile is currently generated by multi-element arrays which, over time, have tended toward increasing element count. We recently introduced a new approach, consisting of a single-element transducer coupled to an acoustic lens of controlled thickness.

View Article and Find Full Text PDF

Cavitation activity induced by ultrasound may occur during high intensity focused ultrasound (HIFU) treatment, due to bubble nucleation under high peak negative pressure, and during blood-brain-barrier (BBB) disruption, due to injected ultrasound contrast agents (UCAs). Such microbubble activity has to be monitored to assess the safety and efficiency of ultrasonic brain treatments. In this study, we aim at assessing whether cavitation occurs within cerebral tissue by binary discriminating cavitation activity originating from the inside or the outside of the skull.

View Article and Find Full Text PDF

The development of multi-element arrays for better control of the shape of ultrasonic beams has opened the way for focusing through highly aberrating media, such as the human skull. As a result, the use of brain therapy with transcranial-focused ultrasound has rapidly grown. Although effective, such technology is expensive.

View Article and Find Full Text PDF