Evaluation of the current status, significance and availability of multiparametric prostate MRI and MRI-guided biopsy in Germany.A voluntary web-based questionnaire with 26 distinct items was emailed to members of the German Radiological Society (DRG) and the Professional Association of German Radiologists (BDR). The questions referred to personal qualification, acquisition, quality, and management of prostate MRI, and assessment of the importance of the method.
View Article and Find Full Text PDFPurpose: To characterize the diffusion time (Δ) dependence of apparent diffusion coefficient (ADC) and intravoxel incoherent motion-related parameters in the human kidney at 3 T.
Methods: Sixteen healthy volunteers underwent an MRI examination at 3 T including diffusion-weighted imaging at different Δ ranging from 24.1 to 104.
Purpose: Development of a color scheme representation to facilitate the interpretation of tri-exponential DWI data from abdominal organs, where multi-exponential behavior is more pronounced.
Methods: Multi-exponential analysis of DWI data provides information about the microstructure of the tissue under study. The tri-exponential signal analysis generates numerous parameter images that are difficult to analyze individually.
Unlabelled:
Background: Despite the availability of vaccines, there is an increasing number of SARS-CoV-2-breakthrough-infections.
Objective: The aim of this study was to determine whether there is a radiological difference in lung parenchymal involvement between infected vaccinated and unvaccinated patients. Additionally, we aimed to investigate whether vaccination has an impact on the course of illness and the need for intensive care.
Diffusion measurements in the kidney are affected not only by renal microstructure but also by physiological processes (i.e., glomerular filtration, water reabsorption, and urine formation).
View Article and Find Full Text PDFAlthough iso-centric patient positioning is enormously important in computed tomography (CT), it is complicated in thoracoabdominal imaging by the varying dimensions of the body. Patient positioning can affect the appearance of the patient on the localiser. Positioned too close to the x-ray tube, a patient appears considerably more voluminous.
View Article and Find Full Text PDFAnalysis of chemical exchange saturation transfer (CEST) MRI data requires sophisticated methods to obtain reliable results about metabolites in the tissue under study. CEST generates z-spectra with multiple components, each originating from individual molecular groups. The individual lines with Lorentzian line shape are mostly overlapping and disturbed by various effects.
View Article and Find Full Text PDFHepatic encephalopathy (HE) is a common neurological manifestation of liver cirrhosis and is characterized by an increase of ammonia in the brain accompanied by a disrupted neurotransmitter balance, including the GABAergic and glutamatergic systems. The aim of this study is to investigate metabolic abnormalities in the cerebello-thalamo-cortical system of HE patients using GABA-edited MRS and links between metabolite levels, disease severity, critical flicker frequency (CFF), motor performance scores, and blood ammonia levels. GABA-edited MRS was performed in 35 participants (16 controls, 19 HE patients) on a clinical 3 T MRI system.
View Article and Find Full Text PDFPurpose: To improve the reliability of intravoxel incoherent motion (IVIM) model parameter estimation for the DWI in the kidney using a novel image downsampling expedited adaptive least-squares (IDEAL) approach.
Methods: The robustness of IDEAL was investigated using simulated DW-MRI data corrupted with different levels of Rician noise. Subsequently, the performance of the proposed method was tested by fitting bi- and triexponential IVIM model to in vivo renal DWI data acquired on a clinical 3 Tesla MRI scanner and compared to conventional approaches (fixed D* and segmented fitting).
Deep-learning (DL) noise reduction techniques in computed tomography (CT) are expected to reduce the image noise while maintaining the clinically relevant information in reduced dose acquisitions. This study aimed to assess the size, attenuation, and objective image quality of reno-ureteric stones denoised using DL-software in comparison to traditionally reconstructed low-dose abdominal CT-images and evaluated its clinical impact. In this institutional review-board-approved retrospective study, 45 patients with renal and/or ureteral stones were included.
View Article and Find Full Text PDFBased on in silico, in vitro, in situ, and in vivo evaluations, this study aims to establish and optimize the chemical exchange saturation transfer (CEST) imaging of lactate (Lactate-CEST—LATEST). To this end, we optimized LATEST sequences using Bloch−McConnell simulations for optimal detection of lactate with a clinical 3 T MRI scanner. The optimized sequences were used to image variable lactate concentrations in vitro (using phantom measurements), in situ (using nine human cadaveric lower leg specimens), and in vivo (using four healthy volunteers after exertional exercise) that were then statistically analyzed using the non-parametric Friedman test and Kendall Tau-b rank correlation.
View Article and Find Full Text PDFPurpose: To assess whether it is possible to reliably detect patients with strong suspicion of COVID-19 despite initially negative quantitative polymerase-chain-reaction (qPCR) tests by means of computed tomography (CT).
Materials And Methods: 437 patients with suspected COVID-19 but initially negative qPCR and subsequent chest CT between March 13 and November 30, 2020 were included in this retrospective study. CT findings were compared to results of successive qPCR tests (minimum of 3 qPCR tests if CT suggested infection) to determine the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT for diagnosing COVID-19.
Purpose: To assess the performance of two point (2-pt) Dixon-based chemical exchange saturation transfer (CEST) imaging for fat suppression in renal transplant patients.
Methods: The 2-pt Dixon-based CEST MRI was validated in an egg-phantom and in fourteen renal transplant recipients (5 females and 9 males; age range: 23-78 years; mean age: 51 ± 16.8).
Purpose: Classifications were created to facilitate radiological evaluation of the novel coronavirus disease 2019 (COVID-19) on computed tomography (CT) images. The categorical CT assessment scheme (CO-RADS) categorizes lung parenchymal changes according to their likelihood of being caused by SARS-CoV-2 infection. This study investigates the diagnostic accuracy of diagnosing COVID-19 with CO-RADS compared to the Thoracic Imaging Section of the German Radiological Society (DRG) classification and Radiological Society of North America (RSNA) classification in an anonymized patient cohort.
View Article and Find Full Text PDFContrast-induced nephropathy (CIN) resembles an important complication of radiographic contrast medium (XCM) displayed by a rise in creatinine levels 48-72 h after XCM administration. The purpose of the current study was to evaluate microstructural renal changes due to CIN in high-risk patients by diffusion weighted (DWI) and diffusion tensor imaging (DTI). Fifteen patients (five CIN and ten non-CIN) scheduled for cardiological intervention were included in the study.
View Article and Find Full Text PDFThe specialized function of the kidney is reflected in its unique structure, characterized by juxtaposition of disorganized and ordered elements, including renal glomerula, capillaries, and tubules. The key role of the kidney in blood filtration, and changes in filtration rate and blood flow associated with pathological conditions, make it possible to investigate kidney function using the motion of water molecules in renal tissue. Diffusion-weighted imaging (DWI) is a versatile modality that sensitizes observable signal to water motion, and can inform on the complexity of the tissue microstructure.
View Article and Find Full Text PDFPurpose: To assess the feasibility of measuring tubular and vascular signal fractions in the human kidney using nonnegative least-square (NNLS) analysis of intravoxel incoherent motion data collected in healthy volunteers and patients with renal pathologies.
Methods: MR imaging was performed at 3 Tesla in 12 healthy subjects and 3 patients with various kidney pathologies (fibrotic kidney disease, failed renal graft, and renal masses). Relative signal fractions f and mean diffusivities of the diffusion components in the cortex, medulla, and renal lesions were obtained using the regularized NNLS fitting of the intravoxel incoherent motion data.
Objective: To evaluate the feasibility of in-vivo quantitative susceptibility mapping (QSM) of the human kidney.
Methods: An axial single-breath-hold 3D multi-echo sequence (acquisition time 33 s) was completed on a 3 T-MRI-scanner (Magnetom Prisma, Siemens Healthineers, Erlangen, Germany) in 19 healthy volunteers. Graph-cut-based unwrapping combined with the T*-IDEAL approach was performed to remove the chemical shift of fat and to quantify QSM of the upper abdomen.
Background: Motion correction is mandatory for the functional Fourier decomposition magnetic resonance imaging (FD-MRI) of the lungs. Therefore, it is important to evaluate the quality of various image-registration algorithms for pulmonary FD-MRI and to determine their impact on FD-MRI outcome.
Purpose: To evaluate different image-registration algorithms for FD-MRI in functional lung imaging.
Objective: To establish and optimize a stable 3 Tesla (T) glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging protocol for assessing the articular cartilage of the tibiotalar joint in healthy volunteers and patients after a sustained injury to the ankle.
Methods: Using Bloch-McConnell simulations, we optimized the sequence protocol for a 3 T MRI scanner for maximum gagCEST effect size within a clinically feasible time frame of less than 07:30 min. This protocol was then used to analyze the gagCEST effect of the articular cartilage of the tibiotalar joint of 17 healthy volunteers and five patients with osteochondral lesions of the talus following ankle trauma.
Objective: To measure sodium relaxation times and concentrations in human wrists on a clinical magnetic resonance imaging (MRI) scanner with a density-adapted radial sequence.
Materials And Methods: Sodium MRI of human wrists was conducted on a 3T MR system using a dual-tuned H/Na surface coil. We performed two studies with 10 volunteers each investigating either sodium T (study 1) or sodium T* (study 2) relaxation times in the radiocarpal joint (RCJ) and midcarpal joint (MCJ).