Background: Smart devices that are able to measure blood pressure (BP) are valuable for hypertension or heart failure management using digital technology. Data regarding their diagnostic accuracy in comparison to standard noninvasive measurement in accordance to Riva-Rocci are sparse. This study compared a wearable watch-type oscillometric BP monitor (Omron HeartGuide), a wearable watch-type infrared BP monitor (Smart Wear), a conventional ambulatory BP monitor, and auscultatory sphygmomanometry.
View Article and Find Full Text PDFIntroduction: One of the most helpful aspects of intracardiac echocardiography (ICE) implementation in electrophysiological studies (EPS) is the real-time visualisation of catheters and cardiac structures. In this prospective study, we investigated ICE-guided zero-fluoroscopy catheter navigation during radiofrequency (RF) ablation of the cavotricuspid isthmus (CTI) in patients with typical atrial flutter (AFL).
Methods And Results: Thirty consecutive patients (mean age 72.
Background: Mechanical circulatory support devices are able to generate additional cardiac output or maintain sufficient circulation during high-risk PCI. We prospectively compared the hemodynamic and clinical performance of the new iVAC2L® device with the Impella 2.5® device during high-risk PCI.
View Article and Find Full Text PDFBackground: Patients at high risk of bleeding requiring percutaneous coronary intervention (PCI) need careful evaluation of both their thrombotic and their bleeding risks. In these patients, a polymer-free metallic stent coated with biolimus-A9 (BA9-DCS) followed by 1‑month dual antiplatelet therapy (DAPT) could be a safe option; however, real-world data are still lacking. We analyzed the performance of the device in a real-world scenario.
View Article and Find Full Text PDFCardiac arrhythmias and cardiovascular diseases are a major public health problem in developed countries. A major goal in preventive medicine is the reduction of cardiovascular death by early detection of atrial fibrillation (AF), which may cause stroke, or early detection of life-threatening myocardial ischemia in acute coronary syndrome. Detection of arrhythmia is often challenging if symptoms occur when patients have no chance for immediate electrocardiogram (ECG) diagnostic testing, or if the observation time period is short or an immediate visit to their doctor is not possible.
View Article and Find Full Text PDFBackground: Smartwatches that are able to record a bipolar ECG and Einthoven leads were recently described. Nevertheless, for detection of ischemia or other cardiac diseases more leads are required, especially Wilson's chest leads.
Objectives: Feasibility study of six single-lead smartwatch (Apple Watch Series 4) ECG recordings including Einthoven (I, II, III) and Wilson-like pseudo-unipolar chest leads (Wr, Wm, Wl).
Background: During high-risk percutaneous coronary intervention (PCI) complications may occur, leading to unstable hemodynamic conditions. Circulatory support devices might help to intercept these conditions by supporting cardiac output. We investigated in a prospective trial the performance of the pulsatile iVAC2L system in the setting of high-risk PCI.
View Article and Find Full Text PDFBackground: Standardization in clinical documentation can increase efficiency and can save time and resources.
Objective: The objectives of this work are to compare documentation forms for acute coronary syndrome (ACS), check for standardization, and generate a list of the most common data elements using semantic form annotation with the Unified Medical Language System (UMLS).
Methods: Forms from registries, studies, risk scores, quality assurance, official guidelines, and routine documentation from four hospitals in Germany were semantically annotated using UMLS.
Feasibility study of accurate three lead ECG recording (Einthoven I, II and III) using an Apple Watch Series 4. : In 50 healthy subjects (18 male; age: 40 ± 12 years) without known cardiac disorders, a 12-lead ECG and three bipolar ECGs, corresponding to Einthoven leads I, II and III were recorded using an Apple Watch Series 4. Einthoven I was recorded with the watch on the left wrist and the right index finger on the crown, Einthoven II with the watch on the left lower abdomen and the right index finger on the crown, Einthoven III with the watch on the left lower abdomen and the left index finger on the crown.
View Article and Find Full Text PDFIntroduction: Remote monitoring including transmission of electrocardiogram (ECG) strips has been implemented in implantable cardiac monitors (ICM). We appraise whether the physician can rely on remote monitoring to be informed of all possibly significant arrhythmias.
Methods: We analyzed remote monitoring transmissions of patients in the ongoing BIO|GUARD-MI study, in which Biotronik devices are used.
Introduction: Efforts in percutaneous coronary intervention (PCI) lead to interventional treatment of complex stenoses as an alternative to coronary bypass surgery. Nevertheless, complications during PCI can occur with sudden need for circulatory support. Circulatory support devices are helpful tools during high-risk PCI to generate additional output or maintain sufficient circulation in critical situations.
View Article and Find Full Text PDFIntroduction: Transradial coronary angiography (TRC) can be performed with a one-catheter approach for the right and left coronary ostium (R/LCO). We investigated the performance of a special diagnostic catheter widely used for the one-catheter-approach, the Tiger (Tiger II, TerumoTM).
Methods: In a dual center registry we analyzed 1412 TRC-procedures exclusively performed by experienced TRC-operators.
Objective: To report the long-term safety and efficacy data of a third generation drug eluting stent (DES) with biodegradable polymer in the complex patient population of diabetes mellitus after a follow-up period of 5 years.
Background: After percutaneous coronary intervention patients with diabetes mellitus are under higher risk of death, restenosis and stent thrombosis (ST) compared to non-diabetic patients.
Methods: In 126 centers worldwide 3067 patients were enrolled in the NOBORI 2 registry, 888 patients suffered from diabetes mellitus (DM), 213 of them (14%) being insulin dependent (IDDM).
Percutaneous coronary intervention of complex stenoses is becoming more and more of an alternative to coronary bypass surgery. Nevertheless, complications can occur and lead to the need for circulatory support and/or emergency surgery. Circulatory support devices like the intra-aortic balloon pump showed only low benefit in patients' outcome.
View Article and Find Full Text PDFBackground: We investigated whether multichannel ECG-recordings are useful to risk-stratify patients with congenital long-QT syndrome (LQTS) for risk of sudden cardiac death under optimized medical treatment.
Methods: In 34 LQTS-patients (11 male; age 31±13 years, QTc 478±51ms; LQT1 n = 8, LQT2 n = 15) we performed a standard 12-channel ECG and a 120-channel body surface potential mapping. The occurrence of clinical events (CE; syncope, torsade de pointes (TdP), sudden cardiac arrest (SCA)) was documented and correlated with different ECG-parameters in all lead positions.
Vasc Health Risk Manag
November 2016
Atrial fibrillation (AF) is the most common cardiac arrhythmia, with a projected number of 1 million affected subjects in Germany. Changes in age structure of the Western population allow for the assumption that the number of concerned people is going to be doubled, maybe tripled, by the year 2050. Large epidemiological investigations showed that AF leads to a significant increase in mortality and morbidity.
View Article and Find Full Text PDFBackground: Current recommendations for anticoagulation management during cardioversion are largely based on historical data and expert consensus.
Methods And Results: To characterize current practice of anticoagulation during and after elective cardioversion for AF and the risk of stroke and bleeding events, all patients enrolled into the Flec-SL trial were analyzed for stroke/transient ischemic attack and major bleeds after cardioversion. Flec-SL (ISRCTN62728743, NCT00215774) enrolled 635 patients (mean age 63.
Background: Early-onset pneumonia (EOP) after out-of-hospital cardiac arrest is frequently observed. Causative factors are loss of airway protection during cardiac arrest, pulmonary contusion, and emergency airway management. We assessed the incidence, risk factors, and clinical course of EOP, and evaluated the impact of an early exchange of the prehospitally inserted endotracheal tube (ETT).
View Article and Find Full Text PDFAims: Atrial fibrillation (AF) is the most common cardiac arrhythmia. 'Silent', undiagnosed AF is often only detected with the first complication, e.g.
View Article and Find Full Text PDFAims: Clinical and electrocardiographic (ECG) presentation of patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) and idiopathic right ventricular outflow-tract tachycardia (RVOT) may be similar. The aim of the study was to assess the validity and utility of T-wave integral measurement as an ECG discriminator of patients with ARVC and RVOT using a body surface mapping (BSM).
Methods And Results: A 120-channel BSM with quantitative signal analysis of the T-wave integral was performed in 10 patients with ARVC.
Background: Antiarrhythmic drugs prolong the atrial action potential and refractory period, and thereby prevent recurrent atrial fibrillation after cardioversion. The atrial action potential normalises after 2-4 weeks of sinus rhythm, suggesting that antiarrhythmic drugs might not be needed beyond that period. Therefore, we investigated whether short-term antiarrhythmic drug treatment after cardioversion is non-inferior to long-term treatment.
View Article and Find Full Text PDFHereditary hemorrhagic telangiectasia is an autosomal dominant vascular disease often manifesting with epistaxis, telangiectasia, and intraparenchymatous arteriovenous malformations. We report on the case of a 71-year-old man who was admitted to hospital due to a tricuspid valve insufficiency. During the following days, the patient developed liver and renal failure; the clinical condition worsened rapidly.
View Article and Find Full Text PDFAims: Induced mild therapeutic hypothermia (MTH) is an effective treatment to improve outcome after out-of-hospital resuscitation. Adverse events are rare, but arrhythmias and bleeding complications have been reported. So far, only few data about electrocardiographic changes and associated events have been reported.
View Article and Find Full Text PDFAim: The aim of this study was to investigate whether interventricular asynchrony (IVA) can be measured by electrocardiography.
Methods: Sixty-two patients (New York Heart Association heart failure functional class III: age, mean +/- SD: 64 +/- 9 years; ejection fraction, mean +/- SD: 24% +/- 8%; dilative cardiomyopathy/ischemic cardiomyopathy, n = 39/23) with left bundle branch block (QRS duration, mean +/- SD: 165 +/- 21 milliseconds) underwent a 120-channel body surface mapping. QRS integral was analyzed and compared with IVA (echo).