Objectives: The aim of this study was to assess 2-year safety and efficacy of the current-generation thin composite-wire-strut durable-polymer Resolute Onyx zotarolimus-eluting stent (ZES), compared with the ultrathin-strut biodegradable-polymer Orsiro sirolimus-eluting stent (SES) in all-comers and a pre-specified small-vessel subgroup analysis.
Background: The Resolute Onyx ZES is widely used in clinical practice, but no follow-up data beyond 1 year have been published. The randomized BIONYX (Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents) trial (NCT02508714) established the noninferiority of ZES versus SES regarding target vessel failure (TVF) rates.
Objectives: The study sought to evaluate for the first time the 5-year outcomes after treating an all-comers population with newer-generation cobalt chromium-based Resolute Integrity zotarolimus-eluting stents (ZES) (Medtronic, Santa Rosa, California) versus platinum chromium-based PROMUS Element everolimus eluting stents (EES) (Boston Scientific, Natick, Massachusetts).
Background: The DUTCH PEERS (TWENTE II) (DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity: TWENTE II) trial is a randomized, multicenter, single-blinded, investigator-initiated all-comers trial that found at its main analysis similar 1-year safety and efficacy for both drug-eluting stents. It is the first randomized trial ever to investigate the Resolute Integrity ZES and the first trial to compare both devices.
Background: Treatment of lesions in small vessels was associated with worse clinical outcome, and various definitions of "small vessels" have been used. Data with novel drug-eluting stents are scarce.
Methods: To compare the outcome of patients with vs without small-vessel treatment, we assessed 2-year follow-up data of the DUTCH PEERS randomized trial (ClinicalTrials.
Background: Percutaneous coronary intervention (PCI) in bifurcated lesions with second-generation drug-eluting stents (DES) was associated with increased myocardial infarction (MI) rates. Flexible stent designs that accommodate well to vessel tapering may be of benefit in challenging anatomies such as bifurcated target lesions, but so far data are scarce.
Methods: We analyzed the 2-year follow-up data of the DUTCH PEERS (TWENTE II) trial, which randomized 1811 all-comer patients to PCI with newer generation resolute integrity zotarolimus-eluting (Medtronic) or promus element everolimus-eluting stents (Boston Scientific).
Background: Third-generation, permanent-polymer-based drug-eluting stents with novel, flexible designs might be more easily delivered than previous generations of stents in complex coronary lesions, but might be less longitudinally stable. We aimed to assess the safety and efficacy in all-comer patients of two third-generation stents that are often used clinically, but that have not yet been compared, and one of which has not previously been assessed in a randomised trial.
Methods: In this investigator-initiated, single-blind, multicentre, randomised, two-arm, non-inferiority trial, patients aged 18 years and older who required a percutaneous coronary intervention with implantation of a drug-eluting stent were recruited from four study sites in the Netherlands.