Publications by authors named "Alexander R Podgorsak"

Article Synopsis
  • Doctors use special scans like CT and MRI to help with prostate cancer treatment.
  • They created a computer program called PxCGAN that makes fake MRI images from CT scans to help when they can't use MRI.
  • Tests showed that these fake MRIs (sMRI) are just as good at showing the prostate as real MRIs (rMRI), which helps doctors treat patients better.
View Article and Find Full Text PDF

Purpose: Target and organ delineation during prostate high-dose-rate (HDR) brachytherapy treatment planning can be improved by acquiring both a postimplant CT and MRI. However, this leads to a longer treatment delivery workflow and may introduce uncertainties due to anatomical motion between scans. We investigated the dosimetric and workflow impact of MRI synthesized from CT for prostate HDR brachytherapy.

View Article and Find Full Text PDF

Purpose: In recent years, endovascular treatment has become the dominant approach to treat intracranial aneurysms (IAs). Despite tremendous improvement in surgical devices and techniques, 10-30% of these surgeries require retreatment. Previously, we developed a method which combines quantitative angiography with data-driven modeling to predict aneurysm occlusion within a fraction of a second.

View Article and Find Full Text PDF

Background: The aim of the study was to develop and assess a technique for the optimization of breast electronic tissue compensation (ECOMP) treatment plans based on the breast radius and separation.

Materials And Methods: Ten ECOMP plans for 10 breast cancer patients delivered at our institute were collected for this work. Pre-treatment CT-simulation images were anonymized and input to a framework for estimation of the breast radius and separation for each axial slice.

View Article and Find Full Text PDF

Data-driven CT-image reconstruction techniques for truncated or sparsely acquired projection data to reduce radiation dose, iodine volume, and patient motion artifacts have been proposed. These approaches have shown good performance and preservation of image quality metrics. To continue these efforts, we investigated whether these techniques affect the performance of a machine-learning algorithm to identify the presence of intracranial hemorrhage (ICH).

View Article and Find Full Text PDF

Digital subtraction angiography (DSA) is the main imaging modality used to assess reperfusion during mechanical thrombectomy (MT) when treating large vessel occlusion (LVO) ischemic strokes. To improve this visual and subjective assessment, hybrid models combining angiographic parametric imaging (API) with deep learning tools have been proposed. These models use convolutional neural networks (CNN) with single view individual API maps, thus restricting use of complementary information from multiple views and maps resulting in loss of relevant clinical information.

View Article and Find Full Text PDF

Purpose: Computed tomography perfusion (CTP) is used to diagnose ischemic strokes through contralateral hemisphere comparisons of various perfusion parameters. Various perfusion parameter thresholds have been utilized to segment infarct tissue due to differences in CTP software and patient baseline hemodynamics. This study utilized a convolutional neural network (CNN) to eliminate the need for non-universal parameter thresholds to segment infarct tissue.

View Article and Find Full Text PDF

To assess acute ischemic stroke (AIS) severity, infarct is segmented using computed tomography perfusion (CTP) software, such as RAPID, Sphere, and Vitrea, relying on contralateral hemisphere thresholds. Since this approach is potentially patient dependent, we investigated whether convolutional neural networks (CNNs) could achieve better performances without the need for contralateral hemisphere thresholds. CTP and diffusion-weighted imaging (DWI) data were retrospectively collected for 63 AIS patients.

View Article and Find Full Text PDF

Computed tomography perfusion (CTP) is crucial for acute ischemic stroke (AIS) patient diagnosis. To improve infarct prediction, enhanced image processing and automated parameter selection have been implemented in Vital Images' new CTP+ software. We compared CTP+ with its previous version, commercially available software (RAPID and Sphere), and follow-up diffusion-weighted imaging (DWI).

View Article and Find Full Text PDF

Purpose: Intra-procedural assessment of reperfusion during mechanical thrombectomy (MT) for emergent large vessel occlusion (LVO) stroke is traditionally based on subjective evaluation of digital subtraction angiography (DSA). However, semi-quantitative diagnostic tools which encode hemodynamic properties in DSAs, such as angiographic parametric imaging (API), exist and may be used for evaluation of reperfusion during MT. The objective of this study was to use data-driven approaches, such as convolutional neural networks (CNNs) with API maps, to automatically assess reperfusion in the neuro-vasculature during MT procedures based on the modified thrombolysis in cerebral infarction (mTICI) scale.

View Article and Find Full Text PDF

Purpose: Computed tomography image reconstruction using truncated or sparsely acquired projection data to reduce radiation dose, iodine volume, and patient motion artifacts has been widely investigated. To continue these efforts, we investigated the use of machine learning-based reconstruction techniques using deep convolutional generative adversarial networks (DCGANs) and evaluated its effect using standard imaging metrics.

Methods: Ten thousand head computed tomography (CT) scans were collected from the 2019 RSNA Intracranial Hemorrhage Detection and Classification Challenge dataset.

View Article and Find Full Text PDF

In acute ischemic stroke (AIS) patients, eligibility for endovascular intervention is commonly determined through computed tomography perfusion (CTP) analysis by quantifying ischemic tissue using perfusion parameter thresholds. However, thresholds are not uniform across all analysis methods due to dependencies on patient demographics and computational algorithms. This study aimed to investigate optimal perfusion thresholds for quantifying infarct and penumbra volumes using two post-processing CTP algorithms: Vitrea Bayesian and singular value decomposition plus (SVD+).

View Article and Find Full Text PDF

Purpose: Coronary computed tomography angiography (CTA) has one of the highest diagnostic sensitivities for detection of the significance of coronary artery disease (CAD); however, sensitivity is moderate and may result in increased catheterization rates. We performed an efficacy study to determine whether a trained machine learning algorithm that uses coronary CTA data may improve CAD diagnosis accuracy.

Methods: Sixty-four-patient image datasets based on coronary CTA were retrospectively collected to generate eight views considering 45° increments around the coronary artery centerline.

View Article and Find Full Text PDF

Background: CT perfusion (CTP) infarct and penumbra estimations determine the eligibility of patients with acute ischemic stroke (AIS) for endovascular intervention. This study aimed to determine volumetric and spatial agreement of predicted RAPID, Vitrea, and Sphere CTP infarct with follow-up fluid attenuation inversion recovery (FLAIR) MRI infarct.

Methods: 108 consecutive patients with AIS and large vessel occlusion were included in the study between April 2019 and January 2020 .

View Article and Find Full Text PDF

Background: Angiographic parametric imaging (API), based on digital subtraction angiography (DSA), is a quantitative imaging tool that may be used to extract contrast flow parameters related to hemodynamic conditions in abnormal pathologies such as intracranial aneurysms (IAs).

Objective: To investigate the feasibility of using deep neural networks (DNNs) and API to predict IA occlusion using pre- and post-intervention DSAs.

Methods: We analyzed DSA images of IAs pre- and post-treatment to extract API parameters in the IA dome and the corresponding main artery (un-normalized data).

View Article and Find Full Text PDF

Background: Angiographic parametric imaging (API) is an imaging method that uses digital subtraction angiography (DSA) to characterize contrast media dynamics throughout the vasculature. This requires manual placement of a region of interest over a lesion (eg, an aneurysm sac) by an operator.

Objective: The purpose of our work was to determine if a convolutional neural network (CNN) was able to identify and segment the intracranial aneurysm (IA) sac in a DSA and extract API radiomic features with minimal errors compared with human user results.

View Article and Find Full Text PDF

The imaging of objects using high-resolution detectors coupled to CT systems may be made challenging due to the presence of ring artifacts in the reconstructed data. Not only are the artifacts qualitatilvely distracting, they reduce the SNR of the reconstructed data and may lead to a reduction in the clinical utility of the image data. To address these challenges, we introduce a multistep algorithm that greatly reduces the impact of the ring artifacts on the reconstructed data through image processing in the sinogram space.

View Article and Find Full Text PDF

3D printing has been used to create complex arterial phantoms to advance device testing and physiological condition evaluation. Stereolithographic (STL) files of patient-specific cardiovascular anatomy are acquired to build cardiac vasculature through advanced mesh-manipulation techniques. Management of distal branches in the arterial tree is important to make such phantoms practicable.

View Article and Find Full Text PDF

This project assessed the effectiveness of using two different detectors to obtain dual-energy (DE) micro-CT data for the carrying out of material decomposition. A micro-CT coupled to either a complementary metal-oxide semiconductor (CMOS) or an electron multiplying CCD (EMCCD) detector was used to acquire image data of a 3D-printed phantom with channels filled with different materials. At any instance, materials such as iohexol contrast agent, water, and platinum were selected to make up the scanned object.

View Article and Find Full Text PDF

This project investigated the signal thresholding effectiveness at reducing the instrument noise of an electron multiplying charged coupled device (EMCCD) based micro-CT system at low x-ray exposure levels. Scans of a mouse spine and an iodine phantom were taken using an EMCCD detector coupled with a micro-CT system. An iodine filter of 4 mg/cm area density was placed in the beam.

View Article and Find Full Text PDF

A small animal micro-CT system was built using an EMCCD detectors having complex pre-digitization amplification technology, high-resolution, high-sensitivity and low-noise. Noise in CBCT reconstructed images when using pre-digitization amplification behaves differently than commonly used detectors and warrants a detailed investigation. In this study, noise power and contrast sensitivity were estimated for the newly built system.

View Article and Find Full Text PDF