Publications by authors named "Alexander O El-Warrak"

The aim of this study was to obtain micro-computed tomography derived measurements of the rat proximal femur, to create parameterized rat hip implants that could be surgically installed in a clinically representative small animal model of joint replacement. The proximal femoral anatomy of N = 25 rats (male, Sprague-Dawley, 390-605 g) was quantified. Key measurements were used to parameterize computer-aided design models of monoblock rat femoral implants.

View Article and Find Full Text PDF

With regard to the canine mandible, a mistaken concept of application is to assume that systemic plate-bone resistance is provided by the implant so that biomechanical position could be ignored. Because the alveolar border of the mandible is a tensile zone, the plate would ideally be positioned near this area while avoiding important structures. The aim of this study was to develop 2 bridging plates for the treatment of a segmental bone defect of the canine mandible using monocortical screws to avoid damage to the tooth roots and remaining neurovascular structures.

View Article and Find Full Text PDF

Objective: To compare effects of sterilization with hydrogen peroxide gas plasma (HPGP), ethylene oxide, and steam on bioadhesive properties of nylon and polyethylene lines used for stabilization of canine stifle joints.

Sample: Samples of a 36.3-kg test nylon leader line, 57.

View Article and Find Full Text PDF

Background: Understanding normal gait requires allowing for variations in normal patterns by the sex, age, and species in question. Therefore, the aim of this study was to evaluate kinetic and temporospatial parameters in clinically healthy sheep from three different age groups with a pressure-sensing walkway. The sheep were judged to be healthy based on the results of complete physical and orthopaedic examinations and had no history of lameness.

View Article and Find Full Text PDF

A male German Shepherd Dog mix was presented for chronic non-weight-bearing lameness of the left hind limb. At clinical examination, the dog's left hind limb had severe joint contractures, with the presence of what appeared to be a second paw. The dog also had 2 sets of external genitalia of opposite phenotypic sex; a complete male reproductive tract with a left retained testicle and a right descended testicle, as well as rudimentary female external genitalia including a hypoplastic vulva with a blind-end vagina and a hypertrophied clitoris.

View Article and Find Full Text PDF

This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type.

View Article and Find Full Text PDF

A consecutive series of cases of dogs and cats with locked jaw syndrome (inability to open or close the mouth) are reported in this study. Dogs were significantly overrepresented (84.0%) and adult dogs were more frequently affected (81.

View Article and Find Full Text PDF

Objective: To create a model in sheep for investigation of early changes related to the formation of an interface membrane in hip prosthesis.

Study Design: Experimental study.

Animals: Twenty-four female adult Swiss Alpine sheep.

View Article and Find Full Text PDF

Background: Aseptic loosening of hip prosthesis as it occurs in clinical cases in human patients was attributed to wear particles of the implants, the response of the tissue dominated by macrophages and the production of inflammatory mediators and matrix degrading enzymes; however, the cascade of events initiating the process and their interaction regarding the time course is still open and discussed controversially. Therefore, the goal of this study was to establish an experimental animal model in sheep allowing to follow the cascade of early mechanical and biochemical events within the interface membrane and study the sequence of how they contribute to the pathological bone resorption necessary for aseptic loosening of the implant.

Methods: A cemented modular system (Biomedtrix) was used as a hip replacement in 24 adult Swiss Alpine sheep, with one group receiving a complete cement mantle as controls (n = 12), and the other group a cement mantle with a standardized, lateral, primary defect in the cement mantle (n = 12).

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessiong20f62fre9rms6ctj6v7beg504smrnnd): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once